Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Impact of color temperature and illuminance of ambient light conditions on the accuracy of complete-arch digital implant scans

dc.contributor.authorOchoa López, Gastón
dc.contributor.authorRevilla León, Marta
dc.contributor.authorGómez Polo, Miguel Ángel
dc.date.accessioned2024-01-19T12:01:39Z
dc.date.available2024-01-19T12:01:39Z
dc.date.issued2023-11-29
dc.description.abstractObjective: The purpose of the present study was to assess the influence of color temperature and illuminance of ambient light on the accuracy of different intraoral scanners (IOSs) in complete-arch implant scans. Methods: An edentulous model with six implants and scan bodies was digitized by using a laboratory scanner (DW-7-140; Dental Wings) to obtain a reference mesh. Fifteen scans were performed employing two intraoral scanners (Trios 4;3Shape A/S and i700; Medit Co) at two illuminances (500 and 1000 lux) and three color temperatures (3200, 4400, and 5600 K). Scanning accuracy was measured by using a 3D metrology software program (Geomagic Control X). Kruskal-Wallis, one-way ANOVA, and pairwise comparison tests were used to analyze the data (α = .05). Results: Significant differences in trueness and precision values were found among the different IOSs under the same ambient lighting condition and among the different lighting conditions for a given IOS (p < .05) except for trueness in i700 groups (p > .05). Conclusions: The influence on the accuracy of color temperature and illuminance varied depending on the intraoral scanner. An optimal ambient scanning light condition was not found; this should be adjusted based on the specific IOS system used. 3200 K of ambient light influences the precision of i700 when performed at 1000 lux, decreasing the accuracy. The variation of color temperature at the same illuminance does not affect the scanning accuracy of TRIOS 4, which obtained better accuracy in all scans at 1000 lux.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationOchoa-López G, Revilla-León M, Gómez-Polo M. Impact of color temperature and illuminance of ambient light conditions on the accuracy of complete-arch digital implant scans. Clin Oral Implants Res. 2023 Nov 28
dc.identifier.doi10.1111/clr.14220
dc.identifier.essn1600-0501
dc.identifier.issn0905-7161
dc.identifier.officialurlhttp://doi.org/10.1111/clr.14220
dc.identifier.pmid38014704
dc.identifier.relatedurlhttps://onlinelibrary.wiley.com/doi/pdfdirect/10.1111/clr.14220
dc.identifier.urihttps://hdl.handle.net/20.500.14352/94035
dc.journal.titleClinical oral implants research
dc.language.isoeng
dc.page.final8
dc.page.initial1
dc.publisherWiley
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu616.314
dc.subject.cdu616.314-089.843
dc.subject.cdu616.314-089.28
dc.subject.cdu616-073.75
dc.subject.keywordAccuracy
dc.subject.keywordAmbient conditions
dc.subject.keywordImplant prosthesis
dc.subject.keywordIntraoral scanner
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.ucmPrótesis dental
dc.subject.ucmAparatos y material odontológicos
dc.subject.unesco32 Ciencias Médicas
dc.subject.unesco3299 Otras Especialidades Médicas
dc.subject.unesco3314 Tecnología Médica
dc.titleImpact of color temperature and illuminance of ambient light conditions on the accuracy of complete-arch digital implant scansen
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number00
dspace.entity.typePublication
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery9700c70b-34f2-4d6a-8e12-92587c9186fb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Impact of color temperature and illuminance of ambient light conditions on the accuracy of complete-arch digital implant scans
Size:
1.62 MB
Format:
Adobe Portable Document Format

Collections