Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Clinical application of bicylindric intraocular lens power calculation method

dc.contributor.authorCalvo Sanz, Jorge Antonio
dc.contributor.authorBonnin Arias, Cristina Natalia
dc.contributor.authorArias Puente, Alfonso
dc.date.accessioned2023-06-16T15:19:07Z
dc.date.available2023-06-16T15:19:07Z
dc.date.issued2020-05-25
dc.descriptionDate of Submission: 01-Jul-2019; Date of Acceptance : 24-Dec-2019; Date of Web Publication: 25-May-2020
dc.description.abstractPurpose: To analyze the reliability of the refractive results prediction obtained in intraocular lens (IOL) calculation using bicylindric power calculation method, with the use of steep and flat keratometry readings compared with the classical mean keratometry calculation method. Methods: Fifty-seven eyes of 57 subjects who underwent cataract surgery were included in this prospective study. Optical biometry was performed with IOLMaster 700 and IOL power calculation was performed using both keratometry readings and the surgically induced astigmatism. Four weeks after surgery, subjective refraction was done. Finally, results obtained with both IOL calculation methods were compared. Results: Mean spherical equivalent using bicylindric IOL power calculation method was -0.082 ± 0.296D, and achieved mean spherical equivalent using classical IOL power method with Haigis formula was -0.088 ± 0.405D. Achieved mean spherical equivalent obtained in subjective refraction after surgery was -0.101 ± 0.265D. Linear correlation between bicylindric method spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.761, P < 0.001), also correlation between Haigis spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.339, P = 0.010). Emmetropia was achieved in 49 of 57 (85.86%) subjects and bicylindric method calculated that 49 of 57 (85.86%) of subjects would get emmetropia (P = 1.000). Classical IOL power calculation estimated that 38/57 subjects would get emmetropia (66.67%) (P = 0.026). Conclusion: The IOL power calculation including both keratometry readings and surgically induced astigmatism seems to be more accurate and provides more precision in refractive prediction than classical calculation method.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/60943
dc.identifier.doi10.4103/ijo.IJO_1237_19
dc.identifier.issn0301-4738
dc.identifier.officialurlhttp://dx.doi.org/10.4103/ijo.IJO_1237_19
dc.identifier.relatedurlhttp://www.ijo.in/article.asp?issn=0301-4738;year=2020;volume=68;issue=6;spage=1073;epage=1078;aulast=Calvo%2DSanz
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6327
dc.issue.number6
dc.journal.titleIndian Journal of Ophthalmology
dc.language.isoeng
dc.page.final1078
dc.page.initial1073
dc.publisherWolters Kluwer Medknow Publications
dc.rightsAtribución-NoComercial-CompartirIgual 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/es/
dc.subject.cdu681.73
dc.subject.cdu617.753
dc.subject.cdu617.741-004.1-089
dc.subject.keywordAstigmatism
dc.subject.keywordintraocular lens power calculation
dc.subject.keywordrefractive outcomes
dc.subject.keywordspherical equivalent
dc.subject.ucmCirugía
dc.subject.ucmOptometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3213 Cirugía
dc.subject.unesco2209.15 Optometría
dc.titleClinical application of bicylindric intraocular lens power calculation method
dc.typejournal article
dc.volume.number68
dspace.entity.typePublication
relation.isAuthorOfPublicationbd1d6d70-bafd-4ab0-a203-4b33b5d9cff1
relation.isAuthorOfPublication.latestForDiscoverybd1d6d70-bafd-4ab0-a203-4b33b5d9cff1

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bonin_IndianJOphthalmol6861073-5966082_163420.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format

Collections