Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Simultaneous amperometric immunosensing of the metastasis-related biomarkers IL-13Rα2 and CDH-17 by using grafted screen-printed electrodes and a composite prepared from quantum dots and carbon nanotubes for signal amplification

dc.contributor.authorSerafín González-Carrato, Verónica
dc.contributor.authorValverde De La Fuente, Alejandro
dc.contributor.authorGarranzo-Asensio, María
dc.contributor.authorBarderas Manchado, Rodrigo
dc.contributor.authorCampuzano Ruiz, Susana
dc.contributor.authorYáñez-Sedeño Orive, Paloma
dc.contributor.authorPingarrón Carrazón, José Manuel
dc.date.accessioned2024-01-25T11:39:33Z
dc.date.available2024-01-25T11:39:33Z
dc.date.issued2019
dc.description.abstractThis paper describes a dual electrochemical immunoassay for the simultaneous determination of IL-13Rα2 and CDH-17, two biomarkers of emerging relevance in metastatic processes. The sandwich assay uses a screen-printed dual carbon electrode that was electrochemically grafted with p-aminobenzoic acid to allow the covalent immobilization of capture antibodies. A hybrid composed of graphene quantum dots (GQDs) and multiwalled carbon nanotubes (MWCNTs) act as nanocarriers for the detection antibodies and horseradish peroxidase. The use of this hybrid material considerably improves the assay (in comparison to the use of MWCNTs) due to the peroxidase mimicking activity of the GQDs. The method works at a low working potential (0.20 V vs. Ag pseudo-reference electrode) and thus is not readily interfered by unknown electroactive species. The dual immunoassay allows for the selective determination of both biomarkers with LOD values of 1.4 (IL-13sRα2) and 0.03 ng mL-1 (CDH-17). The simultaneous determination of IL-13Rα2 and CDH-17 was accomplished in lysates from breast and colorectal cancer cells with different metastatic potential, and in paraffin-embedded tumor tissues extracts from patients diagnosed with colorectal cancer at different stages. The applicability to discriminate the metastatic potential even in intact cells through the detection of both extracellular receptors has been demonstrated also. The assay can be performed within 3 h, requires small sample amounts (0.5 μg), and has a simple protocol. Graphical abstract Dual amperometric immunosensing of the metastasis-related biomarkers IL-13Rα2 and CDH-17 in human colorectal cancer cells and tissues by using grafted screen-printed electrodes and composites of quantum dots and carbon nanotubes as nanocarriers.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (España)
dc.description.sponsorshipComunidad de Madrid
dc.description.sponsorshipInstituto de Salud Carlos III
dc.description.sponsorshipComunidad de Madrid
dc.description.sponsorshipEuropean Commission
dc.description.statuspub
dc.identifier.citationSerafín V, Valverde A, Garranzo-Asensio M, Barderas R, Campuzano S, Yáñez-Sedeño P, Pingarrón J.M. Simultaneous determination of the emerging metastatic biomarkers IL-13Rα2 and CDH-17 using amperometric immunosensors involving grafted screen-printed electrodes and quantum dots/carbon nanotubes as carrier tags for signal amplification. Microchim. Acta. 2019 junio 10; 186(7):411-21
dc.identifier.doi10.1007/s00604-019-3531-5
dc.identifier.essn1436-5073
dc.identifier.issn0026-3672
dc.identifier.officialurlhttps://doi.org/10.1007/s00604-019-3531-5
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/31183566/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/95387
dc.issue.number7
dc.journal.titleMicrochimica Acta
dc.language.isoeng
dc.page.final421
dc.page.initial411
dc.publisherSpringer Wiev
dc.relation.projectIDRTI2018-096135-B-I00
dc.relation.projectIDCTQ2015-64402-C2-1-R
dc.relation.projectIDP2018/NMT-4349
dc.relation.projectIDPI17CIII/00045
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu544.6
dc.subject.keywordColorectal cancer
dc.subject.keywordDual immunosensor
dc.subject.keywordElectrochemical immunosensor
dc.subject.keywordGraphene quantum dots
dc.subject.keywordMetastasis-related biomarkers
dc.subject.keywordParaffin-embedded tissues
dc.subject.keywordPeroxidase mimic
dc.subject.keywordSignal amplification
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.titleSimultaneous amperometric immunosensing of the metastasis-related biomarkers IL-13Rα2 and CDH-17 by using grafted screen-printed electrodes and a composite prepared from quantum dots and carbon nanotubes for signal amplification
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number186
dspace.entity.typePublication
relation.isAuthorOfPublication5b97e8ca-83fe-4ba2-9104-fc1c226f9aab
relation.isAuthorOfPublication24c9ba68-47a3-4737-9656-ef20b29f6f90
relation.isAuthorOfPublication21f5c8af-61fb-4d35-8e88-c01ee15a3bba
relation.isAuthorOfPublication6945fb1e-9c48-459d-b994-e64328c3e79b
relation.isAuthorOfPublication06ab2fa0-2b2d-4b58-80ed-82f9cc767175
relation.isAuthorOfPublication8808f99c-5f56-4562-839a-517626c76dad
relation.isAuthorOfPublication.latestForDiscovery5b97e8ca-83fe-4ba2-9104-fc1c226f9aab

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Amperometric_immunosensing.pdf
Size:
887.76 KB
Format:
Adobe Portable Document Format

Collections