The OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study

dc.contributor.authorCarbajales-Lopez, Julia
dc.contributor.authorBecerro De Bengoa Vallejo, Ricardo
dc.contributor.authorLosa-Iglesias, Marta Elena
dc.contributor.authorCasado Hernández, Israel
dc.contributor.authorBenito-De Pedro, Maria
dc.contributor.authorRodríguez Sanz, David
dc.contributor.authorCalvo Lobo, César
dc.contributor.authorSan Antolín, Marta
dc.date.accessioned2023-06-17T08:56:26Z
dc.date.available2023-06-17T08:56:26Z
dc.date.issued2020-05-28
dc.description.abstractBackground: Walking clinical assessments are commonly used to check for possible gait modifications in healthy subjects, in patients with trauma or neurological conditions, or after a surgical procedure. Spatio-temporal walking variables are studied in depth to achieve a complete evaluation. The purpose of this study was to perform an observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system. Methods: An observational study of the reliability and repeatability of the OptoGait portable photoelectric cell system was carried out. Results: Walking point, walking point gap, step width, and walking base variables, which are deeply related to gait and posture, have an almost perfect reliability. Conclusion: The OptoGait motion analysis device is a reliable system for clinical assessment of static and dynamic foot pressures. Clinicians should feel confident adding this analysis system to their daily professional tools where repeatable measures of gait measurements are important for diagnosis and treatment selection, and also compare efficacy or testing differences between different pathologic conditions. Further, these obtained data can be formed as a baseline for future studies, and to check a right sample size for new research that use the OptoGait motion analysis system.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/63380
dc.identifier.doi10.3390/app10113726
dc.identifier.issn2076-3417
dc.identifier.officialurlhttps://doi.org/10.3390/app10113726
dc.identifier.relatedurlhttps://www.mdpi.com/2076-3417/10/11/3726
dc.identifier.urihttps://hdl.handle.net/20.500.14352/7606
dc.issue.number11
dc.journal.titleApplied Sciences
dc.language.isoeng
dc.page.initial3726
dc.publisherMDPI
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.keywordgait
dc.subject.keywordreliability
dc.subject.keywordanalysis
dc.subject.keywordfoot
dc.subject.ucmEnfermería, Fisioterapia y Podología
dc.subject.ucmPodología
dc.titleThe OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study
dc.typejournal article
dc.volume.number10
dspace.entity.typePublication
relation.isAuthorOfPublicationbbd621a9-7baf-481a-83c7-124287192d07
relation.isAuthorOfPublication67d39ea6-525c-4626-b6c4-4ea6b2c8e7b7
relation.isAuthorOfPublication3d3e5c8a-15a9-4991-97ee-ea886940b1a5
relation.isAuthorOfPublication9420a0f4-5654-4ad9-a920-e9521d454023
relation.isAuthorOfPublication.latestForDiscovery3d3e5c8a-15a9-4991-97ee-ea886940b1a5
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
applsci-10-03726.pdf
Size:
232.2 KB
Format:
Adobe Portable Document Format
Collections