Proximal flow convergence method by three-dimensional color doppler echocardiography for mitral valve area assessment in rheumatic mitral stenosis

dc.contributor.authorDe Agustín Loeches, José Alberto
dc.contributor.authorHernan Mejia
dc.contributor.authorDafne Viliani
dc.contributor.authorPedro Marcos-Alberca
dc.contributor.authorJose Juan Gomez de Diego
dc.contributor.authorIvan Javier Nunez-Gil
dc.contributor.authorCarlos Almeria
dc.contributor.authorRodrigo López, José Luis
dc.contributor.authorLuaces Méndez, María
dc.contributor.authorGarcía Fernández, Miguel Ángel
dc.contributor.authorMacaya Miguel, Carlos
dc.contributor.authorPérez De Isla, Leopoldo
dc.date.accessioned2026-02-03T09:01:15Z
dc.date.available2026-02-03T09:01:15Z
dc.date.issued2014-08-01
dc.description.abstractBackground: The two-dimensional (2D) proximal isovelocity surface area (PISA) method has important technical limitations for mitral valve orifice area (MVA) assessment in mitral stenosis (MS), mainly the geometric assumptions of PISA shape and the requirement of an angle correction factor. Single-beat real-time three-dimensional (3D) color Doppler imaging allows the direct measurement of PISA without geometric assumptions or the requirement of an angle correction factor. The aim of this study was to validate this method in patients with rheumatic MS. Methods: Sixty-three consecutive patients with rheumatic MS were included. MVA was assessed using the transthoracic 2D and 3D PISA methods. Planimetry of MVA (2D and 3D) and the pressure half-time method were used as reference methods. Results: The 3D PISA method had better correlations with the reference methods (with 2D planimetry, r = 0.85, P < .001; with 3D planimetry, r = 0.89, P < .001; and with pressure half-time, r = 0.85, P < .001) than the conventional 2D PISA method (with 2D planimetry, r = 0.63, P < .001; with 3D planimetry, r = 0.66, P < .001; and with pressure half-time, r = 0.68, P < .001). In addition, a consistent significant underestimation of MVA using the conventional 2D PISA method was observed. A high percentage (30%) of patients with nonsevere MS by 3D planimetry were misclassified by the 2D PISA method as having severe MS (effective regurgitant orifice area < 1 cm2 ). In contrast, the 3D PISA method had 94% agreement with 3D planimetry. Good intra- and interobserver agreement for 3D PISA measurements were observed, with intraclass correlation coefficients of 0.95 and 0.90, respectively. Conclusions: MVA assessment using PISA by single-beat real-time 3D color Doppler echocardiography is feasible in the clinical setting and more accurate than the conventional 2D PISA method. (J Am Soc Echocardiogr 2014;27:838-45.)
dc.description.departmentDepto. de Medicina
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationDe Agustin JA, Mejia H, Viliani D, Marcos-Alberca P, Gomez De Diego JJ, Nuñez-Gil IJ, et al. Proximal Flow Convergence Method by Three-Dimensional Color Doppler Echocardiography for Mitral Valve Area Assessment in Rheumatic Mitral Stenosis. Journal of the American Society of Echocardiography 2014;27:838–45. https://doi.org/10.1016/j.echo.2014.04.023.
dc.identifier.doi10.1016/J.ECHO.2014.04.023
dc.identifier.essn0894-7317
dc.identifier.issn1097-6795
dc.identifier.officialurlhttps://doi.org/1097-6795, 0894-7317
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/abs/pii/S0894731714003071?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/131405
dc.journal.titleJournal of the American Society of Echocardiography
dc.language.isoeng
dc.page.final845
dc.page.initial838
dc.publisherElsevier
dc.rights.accessRightsrestricted access
dc.subject.ucmCardiología
dc.subject.unesco3205.01 Cardiología
dc.titleProximal flow convergence method by three-dimensional color doppler echocardiography for mitral valve area assessment in rheumatic mitral stenosis
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number8
dspace.entity.typePublication
relation.isAuthorOfPublicationa4d160b9-b06d-4e03-8aa8-fb88af3fe61b
relation.isAuthorOfPublicationcd5704c0-0c39-47f8-bc66-40af90fe43d2
relation.isAuthorOfPublicationcacd1d83-3ad8-4829-8684-d90aa041927b
relation.isAuthorOfPublication5d7a61fe-bda8-40d7-bbe6-98cf64177dd4
relation.isAuthorOfPublicationb775562d-8fda-4abe-aaf2-fd622b25a3e8
relation.isAuthorOfPublication395641a3-ea72-4613-a2f3-85fbf86fae29
relation.isAuthorOfPublication.latestForDiscovery395641a3-ea72-4613-a2f3-85fbf86fae29

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
De Agustin et al. (2014) 3D Doppler for mitral valve area in rheumatic stenosis. J Am Soc Echocardiogr.pdf
Size:
1.68 MB
Format:
Adobe Portable Document Format

Collections