Diffuse Illumination Device to Improve Mesopic Contrast Sensitivity in Drivers.

dc.conference.date19-21 abril, 2013
dc.conference.placeMálaga, España.
dc.conference.title2013 Annual Conference of the European Academy of Optometry and Optics (EAOO)
dc.contributor.authorNavarro Valls, J.J.
dc.contributor.authorChamorro Gutiérrez, Eva
dc.contributor.authorGarcía Rojo, M.
dc.contributor.authorLanga Moraga, Antonio
dc.contributor.authorBonnin Arias, Cristina Natalia
dc.contributor.authorSánchez Ramos, Celia
dc.date.accessioned2024-07-19T11:58:45Z
dc.date.available2024-07-19T11:58:45Z
dc.date.issued2013-04-21
dc.descriptionIncluye resumen e índice.
dc.description.abstractPurpose: To evaluate the influence of a diffuse illumination device located outside the " eld of vision that provokes a controlled pupillar miosis, on the contrast sensitivity in drivers tested in mesopic conditions. Method: Cross-sectional prospective observational study in which contrast sensitivity by Pelli-Robson Test (CS) was evaluated in 49 drivers under 40 years old and 60 drivers over 40. The study was carried out in a simulated setting for night driving with and without the interposition of the diffuse illumination device. The mesopic contrast sensitivity was measured in the absence or presence of glare. Results: In both age groups, a statistically signi" cant improvement of contrast sensitivity was exhibited. In drivers aged over 40, baseline (BS) Pelli-Robson contrast sensitivity scores were: BS=0.83±0.3 and BSg=0.59±0.3 in absence and in presence of glare, whereas values for the interposition of diffuse illumination device (D) were: D=0.93±0.3 (p<0.05) and Dg=0.62±0.3 (p<0.05). On the other hand, in drivers aged under 40, baseline contrast sensitivity values were: BS=1.09±0.2 and BSg=0.95±0.3 whereas the interposition of the mentioned system showed the following values: D=1.27±0.3 (p<0.05) and Dg=1.11±0.3 (p<0.05). Conclusion: Using a diffuse illumination device in the interior of the vehicle provides significant improvement in contrast sensitivity.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/106918
dc.language.isoeng
dc.rights.accessRightsmetadata only access
dc.subject.keywordDiffuse illumination device
dc.subject.keywordMesopic contrast sensitivity
dc.subject.keywordDrivers
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica geométrica e instrumental
dc.subject.unesco2209 Óptica
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3210 Medicina Preventiva
dc.titleDiffuse Illumination Device to Improve Mesopic Contrast Sensitivity in Drivers.
dc.title.alternativeDispositivo de iluminación difusa para mejorar la sensibilidad al contraste mesópico en conductores.
dc.typeconference poster
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication7ab030d7-bbaa-45e4-b265-110ccb4de4b0
relation.isAuthorOfPublicationbd1d6d70-bafd-4ab0-a203-4b33b5d9cff1
relation.isAuthorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAuthorOfPublication.latestForDiscovery7ab030d7-bbaa-45e4-b265-110ccb4de4b0

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
diffuse_illumination_device_to_improve.pdf
Size:
601.77 KB
Format:
Adobe Portable Document Format