Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and WaveOne New Files
dc.contributor.author | Arias Paniagua, Ana María | |
dc.contributor.author | Pérez-Higueras Sánchez-Escalonilla, Juan | |
dc.contributor.author | Macorra García, José Carlos De La | |
dc.date.accessioned | 2023-06-20T03:37:09Z | |
dc.date.available | 2023-06-20T03:37:09Z | |
dc.date.issued | 2012 | |
dc.description.abstract | Introduction: Recent improvements in alloys, kinematics, and concepts have been combined to increase the cyclic fatigue resistance of nickel-titanium (NiTi) instruments. The aim of this study was to compare the cyclic fatigue resistance of new M-Wire reciprocating WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and Reciproc (VDW GmbH, Munich, Germany) files at 2 levels. Methods: Sixty Reciproc and 60 WaveOne new files were fixed to a specifically designed device and tested in tempered steel canals with a 3-mm radius and a 60° angle of curvature. The motor used was programmed as defined by each manufacturer, and the specific reciprocating motion was followed. Thirty files of each brand were tested at 5 mm, and 30 were tested at 13 mm from their tips. The time to failure was registered. Weibull analysis was used to calculate the mean life, beta, and eta parameters. Results: The probability of the mean life was higher for Reciproc than WaveOne files at both levels, with the probability of the Reciproc mean life being 62% higher than that of WaveOne at 5 mm from the tip and 100% higher at 13 mm (all statistically significant). The probability of the mean life was higher at 5 mm than at 13 mm in both systems. The results may have been partially conditioned by the different motions that manufacturers propose for each system. Conclusions: Reciproc files were more resistant to cyclic fatigue than WaveOne files at both distances from the tip. Both systems had greater cyclic fatigue resistance at 5 mm than at 13 mm from the tip. | en |
dc.description.department | Depto. de Especialidades Clínicas Odontológicas | |
dc.description.faculty | Fac. de Odontología | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/24088 | |
dc.identifier.citation | Arias, A.; Perez-Higueras, J. J.; De La Macorra, J. C. Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and WaveOne New Files. Journal of Endodontics 2012, 38(9), 1244–1248. doi:10.1016/j.joen.2012.05.022. | |
dc.identifier.doi | 10.1016/j.joen.2012.05.022 | |
dc.identifier.issn | 0099-2399 | |
dc.identifier.officialurl | https//doi.org/10.1016/j.joen.2012.05.022 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/44059 | |
dc.issue.number | 9 | |
dc.journal.title | Journal of Endodontics | |
dc.language.iso | spa | |
dc.page.final | 1248 | |
dc.page.initial | 1244 | |
dc.publisher | Elsevier | |
dc.rights.accessRights | open access | |
dc.subject.ucm | Aparatos y material odontológicos | |
dc.subject.ucm | Materiales dentales | |
dc.subject.ucm | Endodoncia | |
dc.subject.unesco | 3311.03 Instrumentos Para Odontología | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.title | Differences in Cyclic Fatigue Resistance at Apical and Coronal Levels of Reciproc and WaveOne New Files | en |
dc.type | journal article | |
dc.volume.number | 38 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | f4270363-d6c5-4ffc-9ebe-c90482776ec1 | |
relation.isAuthorOfPublication | 2dbd67ad-7fd0-4ba6-b60f-a1f7923a9e01 | |
relation.isAuthorOfPublication | 0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884 | |
relation.isAuthorOfPublication.latestForDiscovery | f4270363-d6c5-4ffc-9ebe-c90482776ec1 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Differences_in_Cyclic_Fatigue_Resistance_at_Apical_and_Coronal_Levels_of_Reciproc_and_WaveOne_New_Files.pdf
- Size:
- 452.39 KB
- Format:
- Adobe Portable Document Format