Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Electrochemical immunosensor for the determination of the cytokine interferon gamma (IFN-γ) in saliva

dc.contributor.authorSánchez Tirado, Esther
dc.contributor.authorGonzález Cortés, Araceli
dc.contributor.authorYáñez-Sedeño Orive, Paloma
dc.contributor.authorPingarrón Carrazón, José Manuel
dc.date.accessioned2024-12-16T18:14:39Z
dc.date.available2024-12-16T18:14:39Z
dc.date.issued2020-01-17
dc.description.abstractA simple, fast and sensitive amperometric immunosensing method for the determination of the clinically relevant cytokine interferon gamma (IFN-γ) in saliva complying the requirements demanded for this kind of sample is reported. The target analyte was sandwiched between a specific capture antibody covalently immobilized on a screen-printed electrode functionalized by the diazonium salt grafting of p-aminobenzoic acid, and a biotinylated detector antibody labeled with a streptavidin-horseradish peroxidase conjugate. The amperometric responses measured at - 0.20 V vs Ag pseudo-reference electrode upon addition of hydrogen peroxide in the presence of hydroquinone as the redox mediator allowed a calibration plot with a linear range between 2.5 and 2000 pg mL−1 and a low limit of detection (1.6 pg mL−1) to be obtained. In addition, a good selectivity against other non-target proteins was achieved. The developed method was validated by analyzing a WHO 1st International Standard for IFN-γ. In addition, the immunosensor was used for the determination of the endogenous IFN-γ in saliva with results in excellent agreement with those obtained by a commercial ELISA kit.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationSánchez-Tirado, E.; González-Cortés, A.; Yáñez-Sedeño, P.; Pingarrón, J. M. Electrochemical immunosensor for the determination of the cytokine interferon gamma (IFN-γ) in saliva. Talanta 2020, 211, 120761 DOI:10.1016/j.talanta.2020.120761
dc.identifier.doi10.1016/j.talanta.2020.120761
dc.identifier.issn0039-9140
dc.identifier.officialurlhttps://doi.org/10.1016/j.talanta.2020.120761
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0039914020300527
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112703
dc.issue.number120761
dc.journal.titleTalanta
dc.language.isoeng
dc.page.final8
dc.page.initial1
dc.publisherElsevier
dc.relation.projectIDCTQ2015-64402-C2-1-R
dc.relation.projectIDS2018/NMT-4349
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsembargoed access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu54
dc.subject.keywordInterferon gamma,
dc.subject.keywordElectrochemical immunosensor,
dc.subject.keywordAryl diazonium salt,
dc.subject.keywordGrafting,
dc.subject.keywordSaliva
dc.subject.keywordIFN-γ,
dc.subject.ucmCiencias
dc.subject.unesco23 Química
dc.titleElectrochemical immunosensor for the determination of the cytokine interferon gamma (IFN-γ) in saliva
dc.typejournal article
dc.type.hasVersionCVoR
dc.volume.number211
dspace.entity.typePublication
relation.isAuthorOfPublication8ce0e95b-049c-4147-be76-110e258443a1
relation.isAuthorOfPublication8a730734-cdf5-4b59-b017-12e2320c872e
relation.isAuthorOfPublication06ab2fa0-2b2d-4b58-80ed-82f9cc767175
relation.isAuthorOfPublication8808f99c-5f56-4562-839a-517626c76dad
relation.isAuthorOfPublication.latestForDiscovery8ce0e95b-049c-4147-be76-110e258443a1

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Talanta 2020 IFN-γ in saliva.pdf
Size:
1.32 MB
Format:
Adobe Portable Document Format

Collections