QardioArm(R) Blood pressure monitoring in a population with Type 2 diabetes: Validation Study.
dc.contributor.author | Mazoteras Pardo, Victoria | |
dc.contributor.author | Becerro De Bengoa Vallejo, Ricardo | |
dc.contributor.author | Losa Iglesias, Marta Elena | |
dc.contributor.author | Martínez Jiménez, Eva María | |
dc.contributor.author | Calvo Lobo, César | |
dc.contributor.author | Romero Morales, Carlos | |
dc.contributor.author | López López, Daniel | |
dc.contributor.author | Palomo Lopez, Patricia | |
dc.date.accessioned | 2024-01-11T15:49:47Z | |
dc.date.available | 2024-01-11T15:49:47Z | |
dc.date.issued | 2020-07-24 | |
dc.description.abstract | Background: Home blood pressure monitoring has many benefits, even more so, in populations prone to high blood pressure, such as persons with diabetes. Objective: The purpose of this research was to validate the QardioArm mobile device in a sample of individuals with noninsulin-dependent type 2 diabetes in accordance with the guidelines of the second International Protocol of the European Society of Hypertension. Methods: The sample consisted of 33 patients with type 2 diabetes. To evaluate the validity of QardioArm by comparing its data with that obtained with a digital sphygmomanometer (Omron M3 Intellisense), two nurses collected diastolic blood pressure, systolic blood pressure, and heart rate with both devices. Results: The analysis indicated that the test device QardioArm met all the validation requirements using a sample population with type 2 diabetes. Conclusions: This paper reports the first validation of QardioArm in a population of individuals with noninsulin-dependent type 2 diabetes. QardioArm for home monitoring of blood pressure and heart rate met the requirements of the second International Protocol of the European Society of Hypertension. | |
dc.description.department | Depto. de Enfermería | |
dc.description.faculty | Fac. de Enfermería, Fisioterapia y Podología | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.citation | Mazoteras-Pardo V, Becerro-De-Bengoa-Vallejo R, Losa-Iglesias ME, Martínez-Jiménez EM, Calvo-Lobo C, Romero-Morales C, López-López D, Palomo-López P QardioArm Blood Pressure Monitoring in a Population With Type 2 Diabetes: Validation Study J Med Internet Res 2020;22(7):e19781 doi: 10.2196/19781 PMID: 32706672 PMCID: 7414407 | |
dc.identifier.doi | 10.2196/19781 | |
dc.identifier.issn | 1438-8871 | |
dc.identifier.officialurl | https://www.jmir.org/2020/7/e19781/ | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/92590 | |
dc.issue.number | 7 | |
dc.journal.title | Journal of Medical Internet Research | |
dc.language.iso | eng | |
dc.page.final | 10 | |
dc.page.initial | 1 | |
dc.publisher | JMIR Publications | |
dc.rights | Attribution 4.0 International | en |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject.cdu | 61 | |
dc.subject.cdu | 616.12 | |
dc.subject.keyword | Blood pressure | |
dc.subject.keyword | Hypertension | |
dc.subject.keyword | Type 2 diabetes | |
dc.subject.keyword | Mobile applications | |
dc.subject.keyword | Software validation | |
dc.subject.ucm | Ciencias Biomédicas | |
dc.subject.ucm | Cardiología | |
dc.subject.unesco | 32 Ciencias Médicas | |
dc.title | QardioArm(R) Blood pressure monitoring in a population with Type 2 diabetes: Validation Study. | |
dc.type | journal article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 22 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | bbd621a9-7baf-481a-83c7-124287192d07 | |
relation.isAuthorOfPublication | 7a04a197-3d62-4c6d-90f4-d49924b46327 | |
relation.isAuthorOfPublication | 9420a0f4-5654-4ad9-a920-e9521d454023 | |
relation.isAuthorOfPublication.latestForDiscovery | bbd621a9-7baf-481a-83c7-124287192d07 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2020-mazoteras-Victoria-QardioArm.pdf
- Size:
- 300.8 KB
- Format:
- Adobe Portable Document Format