QardioArm(R) Blood pressure monitoring in a population with Type 2 diabetes: Validation Study.

dc.contributor.authorMazoteras Pardo, Victoria
dc.contributor.authorBecerro De Bengoa Vallejo, Ricardo
dc.contributor.authorLosa Iglesias, Marta Elena
dc.contributor.authorMartínez Jiménez, Eva María
dc.contributor.authorCalvo Lobo, César
dc.contributor.authorRomero Morales, Carlos
dc.contributor.authorLópez López, Daniel
dc.contributor.authorPalomo Lopez, Patricia
dc.date.accessioned2024-01-11T15:49:47Z
dc.date.available2024-01-11T15:49:47Z
dc.date.issued2020-07-24
dc.description.abstractBackground: Home blood pressure monitoring has many benefits, even more so, in populations prone to high blood pressure, such as persons with diabetes. Objective: The purpose of this research was to validate the QardioArm mobile device in a sample of individuals with noninsulin-dependent type 2 diabetes in accordance with the guidelines of the second International Protocol of the European Society of Hypertension. Methods: The sample consisted of 33 patients with type 2 diabetes. To evaluate the validity of QardioArm by comparing its data with that obtained with a digital sphygmomanometer (Omron M3 Intellisense), two nurses collected diastolic blood pressure, systolic blood pressure, and heart rate with both devices. Results: The analysis indicated that the test device QardioArm met all the validation requirements using a sample population with type 2 diabetes. Conclusions: This paper reports the first validation of QardioArm in a population of individuals with noninsulin-dependent type 2 diabetes. QardioArm for home monitoring of blood pressure and heart rate met the requirements of the second International Protocol of the European Society of Hypertension.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationMazoteras-Pardo V, Becerro-De-Bengoa-Vallejo R, Losa-Iglesias ME, Martínez-Jiménez EM, Calvo-Lobo C, Romero-Morales C, López-López D, Palomo-López P QardioArm Blood Pressure Monitoring in a Population With Type 2 Diabetes: Validation Study J Med Internet Res 2020;22(7):e19781 doi: 10.2196/19781 PMID: 32706672 PMCID: 7414407
dc.identifier.doi10.2196/19781
dc.identifier.issn1438-8871
dc.identifier.officialurlhttps://www.jmir.org/2020/7/e19781/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/92590
dc.issue.number7
dc.journal.titleJournal of Medical Internet Research
dc.language.isoeng
dc.page.final10
dc.page.initial1
dc.publisherJMIR Publications
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu61
dc.subject.cdu616.12
dc.subject.keywordBlood pressure
dc.subject.keywordHypertension
dc.subject.keywordType 2 diabetes
dc.subject.keywordMobile applications
dc.subject.keywordSoftware validation
dc.subject.ucmCiencias Biomédicas
dc.subject.ucmCardiología
dc.subject.unesco32 Ciencias Médicas
dc.titleQardioArm(R) Blood pressure monitoring in a population with Type 2 diabetes: Validation Study.
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number22
dspace.entity.typePublication
relation.isAuthorOfPublicationbbd621a9-7baf-481a-83c7-124287192d07
relation.isAuthorOfPublication7a04a197-3d62-4c6d-90f4-d49924b46327
relation.isAuthorOfPublication9420a0f4-5654-4ad9-a920-e9521d454023
relation.isAuthorOfPublication.latestForDiscoverybbd621a9-7baf-481a-83c7-124287192d07
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2020-mazoteras-Victoria-QardioArm.pdf
Size:
300.8 KB
Format:
Adobe Portable Document Format
Collections