Inter-Examiner Disagreement for Assessing Cervical Multifidus Ultrasound Metrics Is Associated with Body Composition Features

dc.contributor.authorVarol, Umut
dc.contributor.authorNavarro Santana, Marcos José
dc.contributor.authorGómez-Sánchez, Sonia
dc.contributor.authorPlaza Manzano, Gustavo
dc.contributor.authorSánchez-Jiménez, Elena
dc.contributor.authorValera Calero, Juan Antonio
dc.date.accessioned2023-06-22T12:56:47Z
dc.date.available2023-06-22T12:56:47Z
dc.date.issued2023
dc.description.abstractUltrasound imaging (US) is a biosensing technique that is widely used in several healthcare disciplines (including physiotherapy) for assessing multiple muscle metrics, such as muscle morphology and quality. Since all biosensors need to be tested in order to demonstrate their reliability, accuracy, sensitivity, and specificity, identifying factors that affect their diagnostic accuracy is essential. Since previous studies analyzed the impact of sociodemographic but not body composition characteristics in US errors, this study aimed to assess whether body composition metrics are associated with ultrasound measurement errors. B-mode images of the lumbar multifidus muscle at the L5 level were acquired and analyzed in 47 healthy volunteers by two examiners (one experienced and one novice). The cross-sectional area, muscle perimeter, and mean echo intensity were calculated bilaterally. A correlation analysis and a multivariate linear regression model were used for assessing the inter-examiner differences with respect to body composition metrics. The results demonstrated good-to excellent reliability estimates for the cross-sectional area, muscle perimeter, aspect ratio, roundness, circularity, and mean brightness metrics (all ICC > 0.85). However, solidity showed unacceptable reliability (ICC < 0.7). Age, height, total lean mass, trunk lean mass, and water volume were associated with inter-examiner disagreement on mean echo intensity. Cross-sectional area, perimeter, and roundness measurement errors were associated with lean mass and water volume.
dc.description.departmentSección Deptal. de Radiología, Rehabilitación y Fisioterapia (Enfermería)
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/77833
dc.identifier.doi10.3390/s23031213
dc.identifier.issn1424-8220
dc.identifier.officialurlhttps://doi.org/10.3390/s23031213
dc.identifier.relatedurlhttps://www.mdpi.com/1424-8220/23/3/1213
dc.identifier.urihttps://hdl.handle.net/20.500.14352/73353
dc.issue.number3
dc.journal.titleSensors
dc.language.isoeng
dc.page.initial1213
dc.publisherMDPI
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu616-073
dc.subject.keywordBody composition
dc.subject.keywordFat
dc.subject.keywordLean mass
dc.subject.keywordUltrasound imaging
dc.subject.keywordSpine
dc.subject.keywordDiagnostic accuracy studies
dc.subject.keywordReliability
dc.subject.ucmFisioterapia (Enfermería, Fisioterapia y Podología)
dc.subject.unesco3213.11 Fisioterapia
dc.titleInter-Examiner Disagreement for Assessing Cervical Multifidus Ultrasound Metrics Is Associated with Body Composition Features
dc.typejournal article
dc.volume.number23
dspace.entity.typePublication
relation.isAuthorOfPublicationd91506ee-5ef0-43c6-a67b-96f83794f686
relation.isAuthorOfPublicatione7f91ea8-207a-4a4b-9dc4-48d4616fe468
relation.isAuthorOfPublication6a199e65-72df-4076-b3cf-c87ead921697
relation.isAuthorOfPublication.latestForDiscoveryd91506ee-5ef0-43c6-a67b-96f83794f686

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
sensors-23-01213.pdf
Size:
5.4 MB
Format:
Adobe Portable Document Format

Collections