Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA Disculpen las molestias.
 

Reliability and minimal detectable change of three functional tests: forward-lunge, step-up-over and sit-to-stand

dc.contributor.authorLuque Siles, Carmen
dc.contributor.authorGallego Izquierdo, Tomas
dc.contributor.authorJímenez Rejano, Jose Jesus
dc.contributor.authorGranados De la Orden, Susana
dc.contributor.authorPlaza Manzano, Gustavo
dc.contributor.authorLópez Illescas Ruiz, Africa
dc.contributor.authorFerragut Garcías, Alejandro
dc.contributor.authorRomero Franco, Natalia
dc.contributor.authorMartín Casas, Patricia
dc.contributor.authorPecos Martín, Daniel
dc.date.accessioned2025-06-17T18:19:52Z
dc.date.available2025-06-17T18:19:52Z
dc.date.issued2016
dc.description.abstract[Purpose] To examine the intrasession and intersession reliability and the absolute reliability of three functional dynamic tests—forward-lunge, step-up-over and sit-to-stand tests—using computerized dynamic posturography. [Subjects and Methods] An intra-test and test-retest, repeated measure study was designed. Forty-five healthy subjects twice carried out the forward-lunge test, step-up-over test, and sit-to-stand test on two days, one week apart. The intrasession and intersession reliabilities as judged by the intraclass correlation coefficient (ICC) and the minimal detectable change of the three functional tests were calculated. [Results] Excellent to very good intrasession reliability of the forward-lunge test (ICC range of 0.9–0.8) was found. Very good to good intrasession reliability of the step-up-over test (ICC range of 0.9–0.5) was found and very good intrasession reliability of the sit-to-stand test (ICC range of 0.8–0.7) was found. The minimal detectable change at the 95% confidence level of most of the measures was lower than 30%. [Conclusion] The forward-lunge, step-up-over and sit-to-stand tests are reliable measurement tools.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationLuque-Siles C, Gallego-Izquierdo T, Jímenez-Rejano JJ, Granados-De-la-orden S, Plaza-Manzano G, López-Illescas-ruiz A, et al. Reliability and minimal detectable change of three functional tests: Forward-lunge, step-up-over and sit-to-stand. Journal of Physical Therapy Science. 2016;28(12):3384-9.
dc.identifier.doi10.1589/jpts.28.3384
dc.identifier.essn2187-5626
dc.identifier.issn0915-5287
dc.identifier.officialurlhttps://doi.org/10.1589/JPTS.28.3384
dc.identifier.relatedurlhttps://www.jstage.jst.go.jp/article/jpts/28/12/28_jpts-2016-474/_article
dc.identifier.urihttps://hdl.handle.net/20.500.14352/121468
dc.issue.number12
dc.journal.titleJournal of Physical Therapy Science
dc.language.isoeng
dc.page.final3389
dc.page.initial3384
dc.publisherSociety of Physical Therapy Science (Rigaku Ryoho Kagakugakkai)
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu61
dc.subject.keywordPostural balance
dc.subject.keywordReproducibility
dc.subject.keywordActivities of daily living
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleReliability and minimal detectable change of three functional tests: forward-lunge, step-up-over and sit-to-stand
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number28
dspace.entity.typePublication
relation.isAuthorOfPublicatione7f91ea8-207a-4a4b-9dc4-48d4616fe468
relation.isAuthorOfPublicationaffec10d-497c-4aae-8366-5f86b383b8c5
relation.isAuthorOfPublication.latestForDiscoverye7f91ea8-207a-4a4b-9dc4-48d4616fe468

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Reliability_and_minimal_detectable_change_of_three_functional_tests.pdf
Size:
555.5 KB
Format:
Adobe Portable Document Format

Collections