Optical Performance of a Monofocal Intraocular Lens Designed to Extend Depth of Focus

dc.contributor.authorVega, Fidel
dc.contributor.authorMillán, María Sagrario
dc.contributor.authorGil, Miguel A.
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2023-11-16T17:22:51Z
dc.date.available2023-11-16T17:22:51Z
dc.date.issued2020
dc.description.abstractPurpose: To test the performance of a new monofocal intraocular lens, intended to extend depth of focus (Tecnis Eyhance, ICB00; Johnson & Johnson Vision, Inc) (ICB-IOL), in comparison to a standard monofocal IOL (Tecnis 1-piece, ZCB00; Johnson & Johnson Vision, Inc) (ZCB-IOL) of the same platform and material. Methods: Assessment of the optical performance of the two IOLs was made in vitro using an optical test bench with a model eye. The spherical aberration, modulation transfer function (MTF), and area under the MTF (MTFa) were obtained for pupil sizes ranging from 2 to 5 mm. Through-focus MTFa curves between -3.00 and +1.00 diopters (D) were obtained with three pupil sizes (2, 3, and 4.5 mm). Halo formation was also assessed for both lenses. Results: The ICB-IOL had slightly worse optical quality at its best focus (ie, lower MTF scores at distance vision) and more negative spherical aberration than the ZCB-IOL for pupils ranging from 2 to 3 mm. The maximum of the through-focus MTFa curve of the ICB-IOL with a 2-mm pupil shifted to a myopic defocus of -0.50 D. For larger pupils (≥ 3.5 mm), there were no differences in spherical aberration, MTF scores, and halo energy between the two lenses. Conclusions: The new ICB-IOL is a modified monofocal lens with 0.50 D of additional power in its central 2-mm zone and more negative spherical aberration values, which induce a myopic shift of the maximum of optical quality and could improve intermediate vision. For pupils larger than 3.5 mm, there were no differences between IOLs. The new ICB-IOL design would produce photic phenomena comparable to a standard IOL.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (España)
dc.description.sponsorshipEuropean Commission
dc.description.statuspub
dc.identifier.citationVega F, Millán MS, Gil MA, Garzón N. Optical Performance of a Monofocal Intraocular Lens Designed to Extend Depth of Focus. J Refract Surg. 2020 Sep 1;36(9):625-632.
dc.identifier.doi10.3928/1081597x-20200710-01
dc.identifier.essn1938-2391
dc.identifier.issn1081-597X
dc.identifier.officialurlhttps://doi.org/10.3928/1081597X-20200710-01
dc.identifier.urihttps://hdl.handle.net/20.500.14352/88766
dc.issue.number9
dc.journal.titleJournal of Refractive Surgery
dc.language.isoeng
dc.page.final632
dc.page.initial625
dc.publisherSlack journals
dc.relation.projectIDDPI2016-76019-R
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.keywordDepth of focus
dc.subject.keywordIntraocular lenses
dc.subject.keywordOptical performance
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco3311.09 Lentes
dc.titleOptical Performance of a Monofocal Intraocular Lens Designed to Extend Depth of Focus
dc.typejournal article
dc.type.hasVersionP
dc.volume.number36
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Monofocal_Intraocular_Lens.pdf
Size:
2.09 MB
Format:
Adobe Portable Document Format

Collections