Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Concurrent Validity and Reliability of Manual Versus Specific Device Transcostal Measurements for Breathing Diaphragm Thickness by Ultrasonography in Lumbopelvic Pain Athletes.

dc.contributor.authorMarugán Rubio, Daniel
dc.contributor.authorBecerro De Bengoa Vallejo, Ricardo
dc.contributor.authorLópez Chicharro, José
dc.contributor.authorLosa Iglesias, Marta Elena
dc.contributor.authorRodríguez Sanz, David
dc.contributor.authorVicente Campos, Davinia
dc.contributor.authorDávila Sánchez, Gabriel J
dc.contributor.authorCalvo Lobo, César
dc.date.accessioned2023-06-17T09:19:21Z
dc.date.available2023-06-17T09:19:21Z
dc.date.issued2021-06-24
dc.descriptionThis work has been supported by the Madrid Government (Comunidad de Madrid- Spain) under the Multiannual Agreement with Complutense University (Reference project number PR65/19-22348) in the line Program to Stimulate Research for Young Doctors in the context of the V PRICIT (Regional Programme of Research and Technological Innovation).
dc.description.abstractThe use of rehabilitative ultrasound imaging (RUSI) to evaluate diaphragm thickness during breathing in athletes who suffer from non-specific lumbopelvic pain presents some measurement errors. The purpose of this study was to evaluate intra- and inter-sessions, intra- and inter-rater reliabilities, and concurrent validity of diaphragm thickness measurements during breathing using transcostal RUSI with a novel thoracic orthotic device that was used to fix the US probe versus those measurements obtained using manual fixation. A total of 37 athletes with non-specific lumbopelvic pain were recruited. Intra- (same examiner) and inter-rater (two examiners) and intra- (same day) and inter-session (alternate days) reliabilities were analyzed. All measurements were obtained after manual probe fixation and after positioning the thoracic orthotic device to fix the US probe in order to correctly correlate both measurement methods. Both left and right hemi-diaphragm thickness measurements were performed by transcostal RUSI at maximum inspiration, expiration, and the difference between the two parameters during relaxed breathing. Intra-class correlation coefficients (ICC), standard errors of measurement (SEM), minimum detectable changes (MCD), systematic errors, and correlations () were assessed. Orthotic device probe fixation showed excellent reliability (ICC = 0.852-0.996, SEM = 0.0002-0.054, and MDC = 0.002-0.072), and most measurements did not show significant systematic errors ( > 0.05). Despite manual probe fixation with a reliability ranging from good to excellent (ICC = 0.714-0.997, SEM = 0.003-0.023, and MDC = 0.008-0.064 cm), several significant systematic measurement errors ( < 0.05) were found. Most significant correlations between both orthotic device and manual probe fixation methods were moderate ( = 0.486-0.718; < 0.05). Bland-Altman plots indicated adequate agreement between both measurement methods according to the agreement limits. The proposed novel thoracic orthotic device may allow ultrasound probe fixation to provide valid and reliable transcostal RUSI measurements of diaphragmatic thickness during relaxed breathing thus reducing some measurement errors and avoiding systematic measurement errors. It may be advisable to measure diaphragm thickness and facilitate visual biofeedback with respect to diaphragm re-education during normal breathing in athletes with non-specific lumbopelvic pain.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.sponsorshipUniversidad Complutense de Madrid/Comunidad de Madrid
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/69357
dc.identifier.doi10.3390/s21134329.
dc.identifier.issn1424-8220
dc.identifier.officialurlhttps://doi.org/10.3390/s21134329
dc.identifier.relatedurlhttps://www.mdpi.com/1424-8220/21/13/4329
dc.identifier.urihttps://hdl.handle.net/20.500.14352/8596
dc.issue.number13
dc.journal.titleSensors (Basel, Switzerland)
dc.language.isoeng
dc.publisherMDPI
dc.relation.projectID(PR65/19-22348)
dc.relation.projectIDV PRICIT (Regional Programme of Research and Technological Innovation)
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.keywordlow back pain
dc.subject.keywordrepeatability
dc.subject.keywordrespiration
dc.subject.keywordultrasonography
dc.subject.keywordvalidity
dc.subject.ucmFisioterapia (Enfermería, Fisioterapia y Podología)
dc.subject.unesco3213.11 Fisioterapia
dc.titleConcurrent Validity and Reliability of Manual Versus Specific Device Transcostal Measurements for Breathing Diaphragm Thickness by Ultrasonography in Lumbopelvic Pain Athletes.
dc.typejournal article
dc.volume.number21
dspace.entity.typePublication
relation.isAuthorOfPublicationbbd621a9-7baf-481a-83c7-124287192d07
relation.isAuthorOfPublication4d976e8b-fa6d-4f5a-8d13-ad192232e5bc
relation.isAuthorOfPublication3d3e5c8a-15a9-4991-97ee-ea886940b1a5
relation.isAuthorOfPublication9420a0f4-5654-4ad9-a920-e9521d454023
relation.isAuthorOfPublication.latestForDiscovery3d3e5c8a-15a9-4991-97ee-ea886940b1a5

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
190.2._2021_Marugán-Rubio et al._Sensors_Orthotic Device Reliability and Diaphragm.pdf
Size:
7.94 MB
Format:
Adobe Portable Document Format

Collections