Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study
dc.contributor.author | Molinero Mourelle, Pedro | |
dc.contributor.author | Roccuzzo, Andrea | |
dc.contributor.author | Yilmaz, Burak | |
dc.contributor.author | Lam, Walter Yu Hang | |
dc.contributor.author | Pow, Edmond Ho Nang | |
dc.contributor.author | Gómez Polo, Miguel Ángel | |
dc.contributor.author | Río Highsmith, Jaime Del | |
dc.date.accessioned | 2023-06-22T11:05:44Z | |
dc.date.available | 2023-06-22T11:05:44Z | |
dc.date.issued | 2022-07-12 | |
dc.description.abstract | Objective: To assess the marginal and bacterial microleakage in zirconia and CADCAM or cast Co-Cr implant abutments. Methods: Sixty-four conical connection implants with their respective abutments were divided into four groups (Co-Cr (milled, laser-sintered, and cast) and Zirconia (milled)). All specimens were subjected to a chewing simulation and thermocycling. After aging process, specimens were submerged in a 0.2% methylene blue solution with Porphyromonas gingivalis (P.g) for 48 h. The marginal microleakage was measured using a 40× optical microscopy at the internal part of the implant, and when positive microleakage was observed, a DNA isolation with a polymerase chain reaction (PCR) test was used. The microbiological assessment was based on colony forming units (CFUs). Results: Thirty (47%) implant-abutments presented microleakage and the PCR was performed on those specimens (1 Zirconia, 1 Co-Cr milled, 14 Co-Cr laser-sintered and 14 cast). Seven specimens (1 Co-Cr laser-sintered and six cast) presented values below the PCR detection limit t (<100 CFUs). The lowest CFUs count occurred in the Co-Cr milled group (5.17E+02 CFUs/ml) followed by zirconia (7.70E+03 CFUs/ml). The Co-Cr cast (9.39E+03 CFUs/ml) and laser-sintered (2.4E+05 CFUs/ml) groups had higher bacterial count. The CFU count comparison performed between Co-Cr cast and laser-sintered resulted in a statistically significant differences in favor of Co-CrCL (p<.05). Conclusions: The abutment material and fabrication technique affected the implantabutment microleakage. Although the CAD-CAM abutments presented favorable results, all tested groups presented microleakage. | en |
dc.description.department | Depto. de Odontología Conservadora y Prótesis | |
dc.description.faculty | Fac. de Odontología | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/74865 | |
dc.identifier.citation | Molinero Mourelle, P., Roccuzzo, A., Yilmaz, B. et al. «Microleakage Assessment of CAD‐CAM Cobalt‐Chrome and Zirconia Abutments on a Conical Connection Dental Implant: A Comparative in Vitro Study». Clinical Oral Implants Research, vol. 33, n.o 9, septiembre de 2022, pp. 945-52. DOI.org (Crossref), https://doi.org/10.1111/clr.13973. | |
dc.identifier.doi | 10.1111/clr.13973 | |
dc.identifier.issn | 0905-7161 | |
dc.identifier.officialurl | https://doi.org/10.1111/clr.13973 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/72098 | |
dc.issue.number | 9 | |
dc.journal.title | Clinical Oral Implants Research | |
dc.language.iso | eng | |
dc.page.final | 952 | |
dc.page.initial | 945 | |
dc.publisher | Wiley | |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/3.0/es/ | |
dc.subject.keyword | Dental implant abutment connection | |
dc.subject.keyword | Dental implant abutment design | |
dc.subject.keyword | Dental implants | |
dc.subject.keyword | Implant supported dental prosthesis | |
dc.subject.keyword | Microleakage | |
dc.subject.keyword | Polymerase chain reaction | |
dc.subject.ucm | Odontología (Odontología) | |
dc.subject.ucm | Implantes dentales | |
dc.subject.ucm | Prótesis dental | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.subject.unesco | 3314.02 Prótesis | |
dc.title | Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study | en |
dc.type | journal article | |
dc.volume.number | 33 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 9700c70b-34f2-4d6a-8e12-92587c9186fb | |
relation.isAuthorOfPublication | b883e312-4337-48d4-89d5-d3e121c92cf7 | |
relation.isAuthorOfPublication.latestForDiscovery | 9700c70b-34f2-4d6a-8e12-92587c9186fb |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Clinical Oral Implants Res - 2022 - Molinero‐Mourelle - Microleakage assessment of CAD‐CAM Cobalt‐Chrome and Zirconia.pdf
- Size:
- 1.05 MB
- Format:
- Adobe Portable Document Format