Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Microleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro study

dc.contributor.authorMolinero Mourelle, Pedro
dc.contributor.authorRoccuzzo, Andrea
dc.contributor.authorYilmaz, Burak
dc.contributor.authorLam, Walter Yu Hang
dc.contributor.authorPow, Edmond Ho Nang
dc.contributor.authorGómez Polo, Miguel Ángel
dc.contributor.authorRío Highsmith, Jaime Del
dc.date.accessioned2023-06-22T11:05:44Z
dc.date.available2023-06-22T11:05:44Z
dc.date.issued2022-07-12
dc.description.abstractObjective: To assess the marginal and bacterial microleakage in zirconia and CADCAM or cast Co-Cr implant abutments. Methods: Sixty-four conical connection implants with their respective abutments were divided into four groups (Co-Cr (milled, laser-sintered, and cast) and Zirconia (milled)). All specimens were subjected to a chewing simulation and thermocycling. After aging process, specimens were submerged in a 0.2% methylene blue solution with Porphyromonas gingivalis (P.g) for 48 h. The marginal microleakage was measured using a 40× optical microscopy at the internal part of the implant, and when positive microleakage was observed, a DNA isolation with a polymerase chain reaction (PCR) test was used. The microbiological assessment was based on colony forming units (CFUs). Results: Thirty (47%) implant-abutments presented microleakage and the PCR was performed on those specimens (1 Zirconia, 1 Co-Cr milled, 14 Co-Cr laser-sintered and 14 cast). Seven specimens (1 Co-Cr laser-sintered and six cast) presented values below the PCR detection limit t (<100 CFUs). The lowest CFUs count occurred in the Co-Cr milled group (5.17E+02 CFUs/ml) followed by zirconia (7.70E+03 CFUs/ml). The Co-Cr cast (9.39E+03 CFUs/ml) and laser-sintered (2.4E+05 CFUs/ml) groups had higher bacterial count. The CFU count comparison performed between Co-Cr cast and laser-sintered resulted in a statistically significant differences in favor of Co-CrCL (p<.05). Conclusions: The abutment material and fabrication technique affected the implantabutment microleakage. Although the CAD-CAM abutments presented favorable results, all tested groups presented microleakage.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/74865
dc.identifier.citationMolinero Mourelle, P., Roccuzzo, A., Yilmaz, B. et al. «Microleakage Assessment of CAD‐CAM Cobalt‐Chrome and Zirconia Abutments on a Conical Connection Dental Implant: A Comparative in Vitro Study». Clinical Oral Implants Research, vol. 33, n.o 9, septiembre de 2022, pp. 945-52. DOI.org (Crossref), https://doi.org/10.1111/clr.13973.
dc.identifier.doi10.1111/clr.13973
dc.identifier.issn0905-7161
dc.identifier.officialurlhttps://doi.org/10.1111/clr.13973
dc.identifier.urihttps://hdl.handle.net/20.500.14352/72098
dc.issue.number9
dc.journal.titleClinical Oral Implants Research
dc.language.isoeng
dc.page.final952
dc.page.initial945
dc.publisherWiley
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subject.keywordDental implant abutment connection
dc.subject.keywordDental implant abutment design
dc.subject.keywordDental implants
dc.subject.keywordImplant supported dental prosthesis
dc.subject.keywordMicroleakage
dc.subject.keywordPolymerase chain reaction
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.ucmPrótesis dental
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco3314.02 Prótesis
dc.titleMicroleakage assessment of CAD-CAM Cobalt-Chrome and Zirconia abutments on a conical connection dental implant: A comparative in vitro studyen
dc.typejournal article
dc.volume.number33
dspace.entity.typePublication
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublicationb883e312-4337-48d4-89d5-d3e121c92cf7
relation.isAuthorOfPublication.latestForDiscovery9700c70b-34f2-4d6a-8e12-92587c9186fb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Clinical Oral Implants Res - 2022 - Molinero‐Mourelle - Microleakage assessment of CAD‐CAM Cobalt‐Chrome and Zirconia.pdf
Size:
1.05 MB
Format:
Adobe Portable Document Format

Collections