Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

High precision calibration method for a four-axis Mueller matrix polarimeter

dc.contributor.authorDel Hoyo Muñoz, Jesús
dc.contributor.authorSánchez Brea, Luis Miguel
dc.contributor.authorGómez Pedrero, José Antonio
dc.date.accessioned2023-06-16T15:17:09Z
dc.date.available2023-06-16T15:17:09Z
dc.date.issued2020-04-11
dc.descriptionReceived 18 November 2019, Revised 3 February 2020, Accepted 23 March 2020, Available online 11 April 2020.
dc.description.abstractWe present a novel method for calibrating a four-axis Mueller matrix polarimeter. This method is valid even for non-ideal optical elements, as it models all polarization elements having both diattenuation and retardance. The method is divided in seven experimental steps, where all the optical elements are calibrated each at a time, plus a numerical fitting process. The fitting method is flexible, allowing to choose between accuracy and speed. The error obtained after the fitting is lower than 0.5% for all steps, and the final error in the determined Mueller matrix elements can be reduced to 4 ×10 −4.
dc.description.departmentSección Deptal. de Óptica (Óptica)
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (MINECO)/FEDER
dc.description.sponsorshipEuropean Funds for Regional Development
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/60054
dc.identifier.doi10.1016/j.optlaseng.2020.106112
dc.identifier.issn0143-8166
dc.identifier.officialurlhttps://doi.org/10.1016/j.optlaseng.2020.106112
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0143816619318263
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6179
dc.issue.number106112
dc.journal.titleOptics and lasers in engineering
dc.language.isoeng
dc.page.initial10 p.
dc.publisherElsevier
dc.relation.projectIDRTC-2016-5277-5
dc.rights.accessRightsrestricted access
dc.subject.cdu535.57
dc.subject.cdu532.59
dc.subject.keywordPolarization
dc.subject.keywordMueller marix
dc.subject.keywordPolarimeter
dc.subject.ucmÓptica (Física)
dc.subject.ucmÓptica no líneal
dc.subject.unesco2209.19 Óptica Física
dc.subject.unesco2209.13 Óptica no lineal
dc.titleHigh precision calibration method for a four-axis Mueller matrix polarimeter
dc.typejournal article
dc.volume.number132
dspace.entity.typePublication
relation.isAuthorOfPublicationeaed2bb8-3f7e-4586-a2f3-29e28ae50394
relation.isAuthorOfPublication72f8db7f-8a25-4d15-9162-486b0f884481
relation.isAuthorOfPublication5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36
relation.isAuthorOfPublication.latestForDiscovery72f8db7f-8a25-4d15-9162-486b0f884481

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Gomez Pedrero_2020_1-s2.0-S0143816619318263-main.pdf
Size:
1.41 MB
Format:
Adobe Portable Document Format

Collections