High precision calibration method for a four-axis Mueller matrix polarimeter
dc.contributor.author | Del Hoyo Muñoz, Jesús | |
dc.contributor.author | Sánchez Brea, Luis Miguel | |
dc.contributor.author | Gómez Pedrero, José Antonio | |
dc.date.accessioned | 2023-06-16T15:17:09Z | |
dc.date.available | 2023-06-16T15:17:09Z | |
dc.date.issued | 2020-04-11 | |
dc.description | Received 18 November 2019, Revised 3 February 2020, Accepted 23 March 2020, Available online 11 April 2020. | |
dc.description.abstract | We present a novel method for calibrating a four-axis Mueller matrix polarimeter. This method is valid even for non-ideal optical elements, as it models all polarization elements having both diattenuation and retardance. The method is divided in seven experimental steps, where all the optical elements are calibrated each at a time, plus a numerical fitting process. The fitting method is flexible, allowing to choose between accuracy and speed. The error obtained after the fitting is lower than 0.5% for all steps, and the final error in the determined Mueller matrix elements can be reduced to 4 ×10 −4. | |
dc.description.department | Sección Deptal. de Óptica (Óptica) | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Economía y Competitividad (MINECO)/FEDER | |
dc.description.sponsorship | European Funds for Regional Development | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/60054 | |
dc.identifier.doi | 10.1016/j.optlaseng.2020.106112 | |
dc.identifier.issn | 0143-8166 | |
dc.identifier.officialurl | https://doi.org/10.1016/j.optlaseng.2020.106112 | |
dc.identifier.relatedurl | https://www.sciencedirect.com/science/article/pii/S0143816619318263 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/6179 | |
dc.issue.number | 106112 | |
dc.journal.title | Optics and lasers in engineering | |
dc.language.iso | eng | |
dc.page.initial | 10 p. | |
dc.publisher | Elsevier | |
dc.relation.projectID | RTC-2016-5277-5 | |
dc.rights.accessRights | restricted access | |
dc.subject.cdu | 535.57 | |
dc.subject.cdu | 532.59 | |
dc.subject.keyword | Polarization | |
dc.subject.keyword | Mueller marix | |
dc.subject.keyword | Polarimeter | |
dc.subject.ucm | Óptica (Física) | |
dc.subject.ucm | Óptica no líneal | |
dc.subject.unesco | 2209.19 Óptica Física | |
dc.subject.unesco | 2209.13 Óptica no lineal | |
dc.title | High precision calibration method for a four-axis Mueller matrix polarimeter | |
dc.type | journal article | |
dc.volume.number | 132 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | eaed2bb8-3f7e-4586-a2f3-29e28ae50394 | |
relation.isAuthorOfPublication | 72f8db7f-8a25-4d15-9162-486b0f884481 | |
relation.isAuthorOfPublication | 5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36 | |
relation.isAuthorOfPublication.latestForDiscovery | 72f8db7f-8a25-4d15-9162-486b0f884481 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Gomez Pedrero_2020_1-s2.0-S0143816619318263-main.pdf
- Size:
- 1.41 MB
- Format:
- Adobe Portable Document Format