Comparison of Two Wavefront Autorefractors: Binocular Open-Field versus Monocular Closed-Field

dc.contributor.authorCarracedo Rodríguez, Juan Gonzalo
dc.contributor.authorCarpena Torres, Carlos
dc.contributor.authorBatres Valderas, Laura
dc.contributor.authorSerramito Blanco, María
dc.contributor.authorGonzález Bergaz, Anahí
dc.date.accessioned2023-06-16T15:15:51Z
dc.date.available2023-06-16T15:15:51Z
dc.date.issued2020-01-03
dc.descriptionReceived: 28 Aug 2019; Revised: 14 Nov 2019; Accepted: 17 Dec 2019; Published: 03 Jan 2020
dc.description.abstractPurpose. To evaluate the agreement and repeatability between a new commercially available binocular open-field wavefront autorefractor, as part of the Eye Refract system, and a monocular closed-field wavefront autorefractor (VX110). Methods. A cross-sectional, randomized, and single-masked study was performed. Ninety-nine eyes of 99 healthy participants (37.22 ± 18.04 years, range 8 to 69 years) were randomly analyzed. Three measurements with the Eye Refract and the VX110 were taken on three different days, under noncycloplegic conditions. Mean spherical equivalent (MSE), cylindrical vectors (J0 and J45), and binocular corrected distance visual acuity (BCDVA) were compared between both autorefractors. An intersession repeatability analysis was done considering the values of repeatability (Sr) and its 95% limit (r). Results. The VX110 showed more negative values (P<0.001) in terms of MSE in comparison with the Eye Refract (0.20 D). Regarding cylindrical vectors, J45 showed statistically significant differences (P=0.001) between both wavefront autorefractors, but they were not clinically relevant (<0.05 D). In BCDVA, there were no statistically significant differences (P=0.667) between both wavefront autorefractors. Additionally, the Eye Refract was more repeatable than the VX110 in terms of both MSE (SrEYE REFRACT = 0.21 D, SrVX110 = 0.53 D) and J0 (SrEYE REFRACT = 0.12 D, SrVX110 = 0.35 D). Conclusions. The Eye Refract provided enough accuracy and reliability to estimate refractive errors in different age groups, achieving better results than the VX110. Therefore, the Eye Refract proved to be a useful autorefractor to be incorporated into clinical practice.
dc.description.departmentDepto. de Optometría y Visión
dc.description.departmentUnidad Docente de Bioquímica y Biología Molecular
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/58890
dc.identifier.doi10.1155/2020/8580471
dc.identifier.issn2090-004X
dc.identifier.officialurlhttps://doi.org/10.1155/2020/8580471
dc.identifier.relatedurlhttps://www.hindawi.com/journals/joph/2020/8580471/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6041
dc.journal.titleJournal of Ophthalmology
dc.language.isoeng
dc.page.initial8580471
dc.publisherHindawi Publishing Corporation
dc.rights.accessRightsopen access
dc.subject.cdu617.75
dc.subject.cdu681.785
dc.subject.keywordWavefront autorefractor
dc.subject.keywordBinocular open-field
dc.subject.keywordMonocular closed-field
dc.subject.keywordVisual fields
dc.subject.keywordAutorefractor
dc.subject.ucmOptometría
dc.subject.ucmÓptica geométrica e instrumental
dc.subject.unesco2209.15 Optometría
dc.subject.unesco2209.06 Óptica geométrica
dc.titleComparison of Two Wavefront Autorefractors: Binocular Open-Field versus Monocular Closed-Field
dc.typejournal article
dc.volume.number2020
dspace.entity.typePublication
relation.isAuthorOfPublication97433353-d31b-4cf5-b2c0-47d2e6703fe5
relation.isAuthorOfPublication4f02194c-ec22-49e9-8e60-937801ef8ac5
relation.isAuthorOfPublication43c348f6-e5ef-4c0d-944c-bf6098098eab
relation.isAuthorOfPublication1ed070b9-44c7-486f-8475-407fbccbd9b7
relation.isAuthorOfPublication.latestForDiscovery97433353-d31b-4cf5-b2c0-47d2e6703fe5

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Carracedo_Hindawi_2020_8580471.pdf
Size:
475.81 KB
Format:
Adobe Portable Document Format

Collections