Simulated vs. real visual performance of an EDOF intraocular lens using adaptive optics technology.

dc.contributor.authorCarrasco-Rojo, Silvia
dc.contributor.authorGiacopinelli, Luca
dc.contributor.authorBaoud Ould Haddi, Inas
dc.contributor.authorGarcía Montero, María
dc.contributor.authorArriola Villalobos, Pedro
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2026-04-08T12:14:48Z
dc.date.available2026-04-08T12:14:48Z
dc.date.issued2026-02-19
dc.description.abstractTo evaluate the predictive accuracy of an adaptive optics visual simulator (SimVis Gekko™) in replicating the optical performance of a nondiffractive extended depth-of-focus (EDOF) intraocular lens (IOL), AcrySof® IQ Vivity™ (Alcon, Fort Worth, USA), prior to cataract surgery. Methods Prospective, single-center, observational, comparative study. A total of 16 eyes from 16 patients with early-stage cataract underwent simulation of the AcrySof® IQ Vivity™ IOL using the SimVis Gekko™ device prior to phacoemulsification. Postoperative outcomes were assessed 1 month after bilateral implantation of the IOL. Monocular defocus curves, visual acuity (VA) at far, intermediate and near distances, and contrast sensitivity were compared between the simulated and actual postoperative results. Correlation between VA and pupil size was analyzed. Results The simulated defocus curve closely matched the postoperative performance, with VA differences of less than one line for vergences between − 1.50 D and + 1.00 D. The only point with more than 1 line of difference occurred at − 3.00 D. Simulated contrast sensitivity was slightly lower than postoperative values but followed a similar trend across spatial frequencies. Distance and intermediate visual acuity were significantly better postoperatively than under simulation, while near VA showed no significant differences. A significant Pearson correlation was found between pupil size and near visual acuity. Conclusion The SimVis Gekko™ device demonstrated high accuracy in simulating the visual outcomes of the AcrySof® IQ Vivity™ IOL, suggesting it may be a valuable tool for preoperative patient counseling and personalized lens selection in clinical practice.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationCarrasco-Rojo S, Giacopinelli L, Baoud Ould Haddi I, García-Montero M, Arriola-Villalobos P, Garzón N. Simulated vs. real visual performance of an EDOF intraocular lens using adaptive optics technology. Graefes Arch Clin Exp Ophthalmol. 2026 Feb 19. doi: 10.1007/s00417-026-07121-7. Epub ahead of print. PMID: 41711804.
dc.identifier.doi10.1007/s00417-026-07121-7
dc.identifier.officialurlhttps://doi.org/10.1007/s00417-026-07121-7
dc.identifier.pmid41711804
dc.identifier.urihttps://hdl.handle.net/20.500.14352/134492
dc.journal.titleGraefes Arch Clin Exp Ophthalmol
dc.language.isoeng
dc.publisherSpringer
dc.rights.accessRightsembargoed access
dc.subject.cdu617.7-089.243
dc.subject.keywordAdaptative optics
dc.subject.keywordExtended depth of focus
dc.subject.keywordIntraocular lens
dc.subject.keywordPresbyopia
dc.subject.keywordVisual simulator
dc.subject.ucmCiencias
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco22 Física
dc.subject.unesco32 Ciencias Médicas
dc.titleSimulated vs. real visual performance of an EDOF intraocular lens using adaptive optics technology.
dc.typejournal article
dc.type.hasVersionP
dspace.entity.typePublication
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication302adf1a-3cda-44c0-a3bd-ef3a9418d76d
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery9b637d56-481e-40c6-a0e6-eb4de92e663c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Simulated_real_visual.pdf
Size:
1.02 MB
Format:
Adobe Portable Document Format

Collections