Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Evaluation of the accuracy of coded healing abutments, scan body, and conventional impressions on implants with different angulations

dc.contributor.authorCarrion Martin, Maria
dc.contributor.authorDíaz Díaz, Pedro
dc.contributor.authorTobar Arribas, Celia
dc.contributor.authorRodríguez Alonso, Verónica
dc.contributor.authorPeláez Rico, Jesús
dc.contributor.authorSuárez García, María Jesús
dc.date.accessioned2025-09-10T08:55:07Z
dc.date.available2025-09-10T08:55:07Z
dc.date.issued2025-08-26
dc.description.abstractPurpose: To evaluate the effect of implant angulation on the accuracy (trueness and precision) of analog (ANA) and digital impressions using coded healing abutment (CHA) and scan body (SB), in implant-supported fixed partial dentures (ISFPDs). Methods: Two mandibular models with internal connection implants were fabricated: one with parallel implants (M1) and another with angulated implants (M2). Three impression techniques were tested: CHA, SB, and conventional open-tray (ANA) (n=10 each). Digital impressions were acquired with an intraoral scanner, whereas conventional impressions were made with splinted open-tray copings and polyvinylsiloxane, then digitized with a laboratory scanner. STL files were imported into CAD software and analyzed with metrological software (Geomagic) to assess accuracy by comparison with coordinate measuring machine (CMM) reference data. Data were analyzed using one-way analysis of variance with Tukey’s HSD post hoc test, t-tests and Levene´s test. Results: SB impressions showed the highest trueness for linear distance and implant positions. No differences were observed between CHA and SB for angulated implants. ANA exhibited greater deviations across most parameters. For precision, SB and CHA outperformed ANA, particularly in M2. Implant angulation reduced ANA accuracy but did not affect digital impressions. Conclusions: Scan bodies provided the highest accuracy, especially in parallel implants. Coded healing abutments demonstrated acceptable accuracy across all variables and comparable performance to scan bodies in angulated implants, representing a viable alternative for digital impressions in ISFPDs.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedFALSE
dc.description.statussubmitted
dc.identifier.urihttps://hdl.handle.net/20.500.14352/123804
dc.language.isoeng
dc.relation.projectIDTED2021-131130B-I00 MCIN/AEI/10.13039/501100011033
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.843-073
dc.subject.keywordImplant-supported prosthesis
dc.subject.keywordDigital impression
dc.subject.keywordCode abutment healing
dc.subject.keywordScan body
dc.subject.keywordAccuracy
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.ucmDiagnóstico por imagen y medicina nuclear
dc.subject.unesco3299 Otras Especialidades Médicas
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco2209.90 Tratamiento Digital. Imágenes
dc.subject.unesco3213 Cirugía
dc.titleEvaluation of the accuracy of coded healing abutments, scan body, and conventional impressions on implants with different angulations
dc.typejournal article
dc.type.hasVersionSMUR
dspace.entity.typePublication
relation.isAuthorOfPublication52b24d58-ecb3-489f-bd7d-6b76e870e5ea
relation.isAuthorOfPublication2ce5448d-f74a-4522-8344-6ca5bc99b3a9
relation.isAuthorOfPublication11b05661-52f4-49a2-891d-4a106a02f9df
relation.isAuthorOfPublication99246851-94a2-44a2-aaa7-813b0dc6f2a0
relation.isAuthorOfPublicationaf92bed3-a22f-48cd-ba53-db36d1188124
relation.isAuthorOfPublication.latestForDiscovery52b24d58-ecb3-489f-bd7d-6b76e870e5ea

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation of the accuracy of coded healing abutments, scan body, and conventional impressions on implants with different angulations.pdf
Size:
283.01 KB
Format:
Adobe Portable Document Format
Description:
Manuscrito - preprint

Collections