Effect of gamma-ray sterilization on phase transformation behavior and fatigue resistance of contemporary nickel-titanium instruments

dc.contributor.authorArias Paniagua, Ana María
dc.contributor.authorMacorra García, José Carlos De La
dc.contributor.authorGovindjee, Sanjay
dc.contributor.authorPeters, Ove A.
dc.date.accessioned2025-05-27T10:32:31Z
dc.date.available2025-05-27T10:32:31Z
dc.date.issued2020-01-20
dc.description.abstractObjectives. The aim of this study was to compare body temperature cyclic fatigue resistance (CF) of heat-treated NiTi rotary instruments submitted to gamma-irradiation or autoclave sterilization. Materials and methods. A total of 176 instruments (88 Hyflex EDM (HEDM) and 88 TRUShape (TS)) were used. Forty-four of each were submitted to gamma-irradiation. Twenty-two in each group were further autoclaved, resulting in a total of eight groups (n = 22 each): TS-γ and HEDM-γ (gamma-irradiated)/TS-γ-ac and HEDM-γ-ac (gamma-irradiated and autoclaved)/TS-non-γ and HEDM-non-γ (non-sterilized controls, non-gamma-irradiated/non-autoclaved)/TS-non-γ-ac and HEDM-non-γ-ac (non-gamma-irradiated and autoclaved). Twenty in each were tested for CF. Weibull parameters were calculated and compared. The remainder was used for differential scanning calorimetry analysis. Results. TS instruments lasted significantly longer if not submitted to gamma-irradiation (TS-non-γ mean-life = 101.5 s, 95 CI% 91.7–112.3; TS-γ mean-life = 83.2 s, 95 CI% 76–91.1); further autoclaving did not significantly affect CF. Gamma-irradiation did not affect HEDM (HEDM-γ mean-life = 717.9 s, 95 CI% 636.8–809.3; HEDM-non-γ: mean-life = 678.8 s, 95 CI% 595.1–744.2); further sterilization significantly decreased fatigue resistance (HEDM-γ-ac mean-life = 524.1 s, 95 CI% 476.1–576.8; HEDM-non-γ-ac mean-life = 570.6, 95 CI% 512.3–635.5). Gamma irradiation benefited HEDM conversion to martensite state and its maintenance, while further autoclave sterilization reverted the benefit. Conclusions. Gamma-irradiation and autoclaving differentially affected fatigue life span and transformation temperatures of contemporary martensitic rotary instruments manufactured with different methods. Clinical relevance. Gamma-ray processing is increasingly utilized by manufacturers for clinician to use fully sterile packaged instruments; however, the sterilization method of choice should vary depending on the effects on the behavior of contemporary martensitic rotary instruments manufactured with different methods.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationArias A, Macorra JC, Govindjee S, Peters OA. Effect of gamma-ray sterilization on phase transformation behavior and fatigue resistance of contemporary nickel-titanium instruments. Clin Oral Investig. 2020 Sep;24(9):3113-3120. doi: 10.1007/s00784-019-03185-4
dc.identifier.doi10.1007/s00784-019-03185-4
dc.identifier.issn1432-6981
dc.identifier.issn1436-3771
dc.identifier.officialurlhttps://doi.org/10.1007/s00784-019-03185-4
dc.identifier.pmid31956927
dc.identifier.relatedurlhttps://link.springer.com/article/10.1007/s00784-019-03185-4
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/31956927/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/120500
dc.issue.number9
dc.journal.titleClinical Oral Investigations
dc.language.isoeng
dc.page.final3120
dc.page.initial3113
dc.publisherSpringer
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu616.314:615.47
dc.subject.keywordCyclic fatigue
dc.subject.keywordGamma-irradiation
dc.subject.keywordGamma-ray sterilization
dc.subject.keywordMartensitic transformation temperature
dc.subject.keywordNiTi
dc.subject.keywordSterilization
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmAparatos y material odontológicos
dc.subject.unesco3299 Otras Especialidades Médicas
dc.subject.unesco3311.03 Instrumentos Para Odontología
dc.titleEffect of gamma-ray sterilization on phase transformation behavior and fatigue resistance of contemporary nickel-titanium instruments
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number24
dspace.entity.typePublication
relation.isAuthorOfPublicationf4270363-d6c5-4ffc-9ebe-c90482776ec1
relation.isAuthorOfPublication0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884
relation.isAuthorOfPublication.latestForDiscoveryf4270363-d6c5-4ffc-9ebe-c90482776ec1

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Clin Oral Investig. 2020 Sep;24(9):3113-3120.pdf
Size:
939.67 KB
Format:
Adobe Portable Document Format

Collections