Pre-operative simulation of post-operative multifocal vision
dc.contributor.author | Viñas, Maria | |
dc.contributor.author | Aissati, Sara | |
dc.contributor.author | Romero, Mercedes | |
dc.contributor.author | Benedi-Garcia, Clara | |
dc.contributor.author | Garzon, Nuria | |
dc.contributor.author | Poyales, Francisco | |
dc.contributor.author | Dorronsoro, Carlos | |
dc.contributor.author | Marcos, Susana | |
dc.contributor.author | Garzón Jiménez, Nuria | |
dc.date.accessioned | 2023-11-20T18:36:41Z | |
dc.date.available | 2023-11-20T18:36:41Z | |
dc.date.issued | 2019 | |
dc.description.abstract | While multifocal intraocular lenses (MIOLs) are increasingly implanted to correct for presbyopia, how one sees with a multifocal correction is hard to explain and imagine. The current study evaluates the quality of various visual simulating technologies by comparing vision with simulated MIOLs pre-operatively and the implanted MIOLs post-operatively in the same patients. Two simulation platforms were used: (1) a custom-developed adaptive optics (AO) system, with two visual simulator devices: a spatial light modulator (SLM) and an optotunable lens operating under temporal multiplexing (SimVis); and (2) a wearable, binocular, large field of view SimVis2Eyes clinical simulator (SimVis Gekko, 2Eyes Vision, Madrid, Spain). All devices were programmed to simulate a trifocal diffractive MIOL (POD F, FineVision, PhysIOL). Eight patients were measured pre-operatively simulating the trifocal lens and post-operatively with implantation of the same MIOL. Through-focus decimal visual acuity (TF VA) was measured (1) monocularly in monochromatic light using a four-alternative-forced-choice procedure in the AO system, and (2) binocularly using a clinical optotype in white light. Visual simulations pre-operatively predict well the TF VA performance found post-operatively in patients implanted with the real IOL. The average RMS difference between TF curves with the different visual simulators was 0.05 ± 0.01. The average RMS difference between the TF VA curves with the SimVis pre-operatively and the real MIOL post-operatively was 0.06 ± 0.01 in both platforms, and it was higher in cataract eyes (0.08 ± 0.01, on average across simulators) than in eyes with clear lens. In either group, the shape of the TF curves is similar across simulators and pre-and post-operatively. TF curves cross-correlated significantly between simulators (lag k = 0, rho = 0.889), as well as with results with the real MIOL implanted (lag k = 0, rho = 0.853). Visual simulations are useful programmable tools to predict visual performance with MIOLs, both in an AO environment and in a clinical simulator. Pre-operative visual simulations and post-operative data are in good agreement. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | European Commission | |
dc.description.sponsorship | Ministerio de Ciencia e Innovación (España) | |
dc.description.sponsorship | PhysIOL Group (Bélgica) | |
dc.description.status | pub | |
dc.identifier.citation | Maria Vinas, Sara Aissati, Mercedes Romero, Clara Benedi-Garcia, Nuria Garzon, Francisco Poyales, Carlos Dorronsoro, and Susana Marcos, "Pre-operative simulation of post-operative multifocal vision," Biomed. Opt. Express 10, 5801-5817 (2019) | |
dc.identifier.doi | 10.1364/boe.10.005801 | |
dc.identifier.issn | 2156-7085 | |
dc.identifier.officialurl | https://doi.org/10.1364/BOE.10.005801 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/88860 | |
dc.issue.number | 11 | |
dc.journal.title | Biomedical Optics Express | |
dc.language.iso | eng | |
dc.page.final | 5817 | |
dc.page.initial | 5801 | |
dc.publisher | Optica Publishung group | |
dc.relation.projectID | ERC-2011-AdC 294099 | |
dc.relation.projectID | H2020 COFUND Marie Curie 291820 program | |
dc.relation.projectID | FIS2014- 56643R | |
dc.relation.projectID | FIS2017-84753R | |
dc.relation.projectID | info:eu-repo/grantAgreement/MECD//FPU16%2F01944/ES/FPU16%2F01944/ | |
dc.relation.projectID | ISCIII DTS16/00127 | |
dc.rights | Attribution 4.0 International | en |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject.cdu | 617.7-089.243 | |
dc.subject.cdu | 681.73 | |
dc.subject.cdu | 617.753.4 | |
dc.subject.keyword | Multifocal IOL, IOLS, Intraocular lens; presbyiopia, Ocular surgery | |
dc.subject.ucm | Oftalmología | |
dc.subject.ucm | Óptica oftálmica | |
dc.subject.ucm | Cirugía | |
dc.subject.ucm | Óptica y optometría | |
dc.subject.unesco | 2209.15 Optometría | |
dc.subject.unesco | 3213.09 Cirugía Ocular | |
dc.subject.unesco | 3311.09 Lentes | |
dc.title | Pre-operative simulation of post-operative multifocal vision | |
dc.type | journal article | |
dc.type.hasVersion | AM | |
dc.volume.number | 10 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 367ce491-287f-4b2a-ba6a-870a393c5609 | |
relation.isAuthorOfPublication.latestForDiscovery | 367ce491-287f-4b2a-ba6a-870a393c5609 |
Download
Original bundle
1 - 1 of 1