Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Biomechanical Tests on Long-Bone Elliptical Medullary-Canal Endoprostheses for Limb Salvage in Dogs

dc.contributor.authorMendaza de Cal, Rosa María
dc.contributor.authorBallesteros, Yolanda
dc.contributor.authorPeso-Fernandez, Salvador
dc.contributor.authordel Real-Romero, Juan Carlos
dc.contributor.authorRodríguez Quirós, Jesús
dc.date.accessioned2023-06-22T12:52:52Z
dc.date.available2023-06-22T12:52:52Z
dc.date.issued2022-11-03
dc.description.abstractSimple Summary Currently, more owners look for offering a better quality of life to their pets. In fact, the complete limb amputation seems to be the last option considered by pet owners in surgeries to save their pets' lives. Although this field is under development in veterinary medicine, we believe that 3D-printed implants for this market sector will improve the advancement in its research by reducing production costs. This would allow the pet owners to select this solution without large expenses, allowing at the same time, advances in this field. For this purpose, mechanical tests have been carried out on implants printed in a high-performance plastic that resembles the resistance of metals-that are traditionally used in veterinary surgery-and the properties of dogs' bones as well. The results obtained have confirmed that the implants could withstand the dog weight in its different gaits, although further comparative studies on the effect of rotation forces applied during the animal's change of direction (evaluated at different paces) are required to confirm their suitability. Exo-endoprosthesis is a limb salvage procedure poorly described for animals, as only expensive metal devices have been used so far. Currently, additive manufacturing (AM) can make this type of implant affordable by exploring a wide new range of materials. However, safety factors should be considered and could be related to kinetic and kinematic studies of canine natural gaits. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was assessed for long canine bones with an elliptical medullary canal. Polyether ether ketone (PEEK) was the material used as an alternative to metal for veterinary traumatology. Poisson's ratio of 3D-printed PEEK material and ex vivo mechanical tests of the customized endoprosthesis were performed for the evaluation. The customized endoprostheses had promising outcomes for the radii of 20 kg dogs. Quasistatic mechanical tests of bone-inserted endoprostheses-pure compression tests-reached a maximum force of 1045.0 +/- 78.0 N. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. Furthermore, torque tests with different adhesives were performed to obtain reference data for future assessments comparing with natural dog movements.
dc.description.departmentDepto. de Medicina y Cirugía Animal
dc.description.facultyFac. de Veterinaria
dc.description.refereedTRUE
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/77655
dc.identifier.doi10.3390/ani12213021
dc.identifier.issn2076-2615
dc.identifier.officialurlhttps://doi.org/10.3390/ani12213021
dc.identifier.relatedurlhttps://www.mdpi.com/2076-2615/12/21/3021
dc.identifier.urihttps://hdl.handle.net/20.500.14352/73286
dc.issue.number21
dc.journal.titleAnimals
dc.language.isoeng
dc.page.initial3021
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.projectIDIND2017/BMD-7726
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.keywordBiomechanical test
dc.subject.keywordTorsional test
dc.subject.keywordFDM
dc.subject.keywordPEEK
dc.subject.keywordExo-endoprosthesis
dc.subject.keywordEx vivo
dc.subject.keywordRadius
dc.subject.keywordCanine
dc.subject.ucmVeterinaria
dc.subject.ucmAnimales de compañía
dc.subject.unesco3109 Ciencias Veterinarias
dc.titleBiomechanical Tests on Long-Bone Elliptical Medullary-Canal Endoprostheses for Limb Salvage in Dogs
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number12
dspace.entity.typePublication
relation.isAuthorOfPublication051bf28f-8419-4c9b-8384-eff547aa69d0
relation.isAuthorOfPublicationc8a1b3c4-28d2-4b43-aba9-49864d5c10ad
relation.isAuthorOfPublication.latestForDiscoveryc8a1b3c4-28d2-4b43-aba9-49864d5c10ad

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Mendaza-DeCal et al. - 2022 - Biomechanical Test of a New Endoprosthesis for Elliptical Medullary Canals in Dogs.pdf
Size:
3.1 MB
Format:
Adobe Portable Document Format

Collections