Rotational stability, centration, and patient satisfaction with a trifocal toric intraocular lens

dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorGarcía Bella, Javier
dc.contributor.authorArriola Villalobos, Pedro
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorVillanueva, Celia
dc.contributor.authorGarcía Feijoo, Julián
dc.date.accessioned2025-09-15T13:27:37Z
dc.date.available2025-09-15T13:27:37Z
dc.date.issued2025-09-01
dc.description.abstractPurpose: To evaluate the rotational stability, decentration, visual outcomes, and patient satisfaction after bilateral implantation of a trifocal toric intraocular lens (IOL), Clareon PanOptix Toric. Setting: San Carlos Hospital, Madrid, Spain. Design: Prospective, single-center, observational, noncomparative. Methods: Patients aged 50 years or older suitable for cataract surgery without comorbidities and with regular corneal astigmatism >1.50 diopters (D) were bilaterally implanted with the Clareon PanOptix Toric IOL and followed up for 3 months. Outcomes measured included IOL displacement and rotation, quantified by the PIOLET software. In addition, refraction and uncorrected visual acuity at far (4 m) were measured, along with corrected visual acuities, monocular and binocular, at far (corrected visual acuity [CDVA]), intermediate (DCIVA), and near (DCNVA) distances. Results: A total of 80 eyes from 40 patients were included in this study. At 3 months, the mean rotation was 1.04 ± 0.97 degrees, and the mean displacement was 0.19 ± 0.36 mm along the x axis and 0.19 ± 0.25 mm along the y axis. The postoperative spherical equivalent was −0.09 ± 0.35 D. Binocularly, the mean visual acuities were CDVA, −0.03 ± 0.05 logMAR; DCIVA, 0.07 ± 0.08 logMAR; and DCNVA, 0.09 ± 0.07 logMAR. Regarding satisfaction, 97% of patients indicated they were either very satisfied or fairly satisfied. Conclusions: The bilateral implantation of the Clareon PanOptix Toric IOL demonstrated excellent rotational stability, minimal decentration, and effective astigmatism correction. It provided strong visual acuity outcomes and high patient satisfaction, making it a viable option for patients seeking spectacle independence.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGarzón, Nuria, et al. «Rotational Stability, Centration, and Patient Satisfaction with a Trifocal Toric Intraocular Lens». Journal of Cataract & Refractive Surgery, vol. 51, n.o 9, septiembre de 2025, pp. 762-68. DOI.org (Crossref), https://doi.org/10.1097/j.jcrs.0000000000001687
dc.identifier.doi10.1097/j.jcrs.0000000000001687
dc.identifier.issn0886-3350
dc.identifier.officialurlhttps://doi.org/10.1097/j.jcrs.0000000000001687
dc.identifier.urihttps://hdl.handle.net/20.500.14352/123935
dc.journal.titleJournal of Cataract and refractive surgery
dc.language.isoeng
dc.publisherWolters Kluwer
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subject.cdu617.7-089.243
dc.subject.keywordIntraocular lens
dc.subject.keywordDecentration
dc.subject.keywordRotational stability
dc.subject.keywordToric
dc.subject.keywordTrifocal
dc.subject.ucmCiencias Biomédicas
dc.subject.ucmCiencias
dc.subject.unesco22 Física
dc.subject.unesco32 Ciencias Médicas
dc.titleRotational stability, centration, and patient satisfaction with a trifocal toric intraocular lens
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication302adf1a-3cda-44c0-a3bd-ef3a9418d76d
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rotational_stability_centration_and_patient.4-1.pdf
Size:
1.89 MB
Format:
Adobe Portable Document Format

Collections