Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design

dc.contributor.authorFernández-Núñez, Sara
dc.contributor.authorPérez-Sanz. Lidia
dc.contributor.authorAlbarrán-Diego, César
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorGarcía Montero, María
dc.contributor.authorGómez Pedrero, José Antonio
dc.date.accessioned2024-12-16T11:50:44Z
dc.date.available2024-12-16T11:50:44Z
dc.date.issued2024-07-24
dc.descriptionSpanish Government Agencia Estatal de Investigación and European Fund for Regional Development (PID2021-122486OA-I00)
dc.description.abstractPurpose The aim of this study is to compare optical quality results obtained in laboratory analysis (in vitro) versus clinical data (in vivo). Methods The optical quality of ISOPure intraocular lens was assessed both in vitro and in vivo using the modulation transfer function (MTF) for 3.0 and 4.5 mm pupil diameters. In vitro measurements were obtained using deflectometer NIMO TRF1504, while in vivo measurements were taken with OPD-Scan III in a set of patients implanted with this lens. Ray tracing techniques were used to determine the MTF and area under MTF curve (MTFa) from the measured wavefront for the isolated lens and for the whole eye. Results The MTF of the isolated lens obtained under both in vitro and in vivo conditions showed comparable results for both pupil sizes. However, differences were found when comparing the MTF of the whole eye with the lens implanted versus the MTF measured in vitro for 4.5 mm pupil size. Also, the MTFa defocus curve was compared with the defocus curve measured in vivo. Conclusion The defocus curve from the in vivo study aligns closely with the MTFa of the in vitro model, with a useful defocus range of 0.40D. Thus, it is possible to anticipate the visual results of the implanted isofocal lens by using measurements on an optical bench and conducting optical simulations.
dc.description.departmentDepto. de Optometría y Visión
dc.description.departmentSección Deptal. de Óptica (Óptica)
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Ciencia e Innovación (España)
dc.description.sponsorshipEuropean Fund for Regional Development
dc.description.statuspub
dc.identifier.citationFernández-Núñez, S., Pérez-Sanz, L., Gómez-Pedrero, J.A. et al. Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design. Graefes Arch Clin Exp Ophthalmol (2024). https://doi.org/10.1007/s00417-024-06590-y
dc.identifier.doi10.1007/s00417-024-06590-y
dc.identifier.essn1435-702X
dc.identifier.issn0721-832X
dc.identifier.officialurlhttps://doi.org/10.1007/s00417-024-06590-y
dc.identifier.pmid39046519
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112660
dc.journal.titleGraefe's Archive for Clinical and Experimental Ophthalmology
dc.language.isoeng
dc.page.final3913
dc.page.initial3905
dc.publisherSpringer
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica, Técnica y de Innovación 2021-2023/PID2021-122486OA-I00/ES/Diseño de algoritmo de decisión clínica en el proceso de selección del tipo de LIO a implantar para corregir la presbicia y cataratas Design of a clinical decision algorithm in the selection process of the type of IOL to be implanted to correct presbyo
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.keywordIOL
dc.subject.keywordEDoF
dc.subject.keywordOptical quality
dc.subject.keywordOptical bench
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco2406.05 Bioóptica
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3311.09 Lentes
dc.titleOptical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number262
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optical_quality_in_vitro.pdf
Size:
2.21 MB
Format:
Adobe Portable Document Format

Collections