Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy

dc.contributor.authorAgustín Panadero, Rubén
dc.contributor.authorMacías Moreno, David
dc.contributor.authorAlonso Pérez-Barquero, Jorge
dc.contributor.authorFernández Estevan, Lucía
dc.contributor.authorGómez Polo, Miguel Ángel
dc.contributor.authorRevilla León, Marta
dc.date.accessioned2024-10-09T10:26:05Z
dc.date.available2024-10-09T10:26:05Z
dc.date.issued2023-07
dc.description2023 Otros acuerdos transformativos UCM
dc.description.abstractObjectives: To assess the influence of different restorative materials and surface wetness on intraoral scanning accuracy. Methods: Reference casts with an extracted second premolar and first and second molar were digitized (L2). Four groups were established according to the material of the first molar: natural tooth (control), zirconia (Z), lithium disilicate (LD), and nanoceramic resin crown (NC). Four subgroups were developed: dry, low-, mild-, and high-wetness subgroups (n = 15). All the scans were completed by using an intraoral scanner (TRIOS 3). In the control-dry subgroup, the reference cast was dry. In the control-low subgroup, artificial saliva was sprayed with a 1 mL/min volumetric flow for 4 s. In the control-mild and control-high subgroups, the same procedures as in the control-low subgroup were performed, but with a volumetric flow of 4 and of 8 mL/min, respectively. In the Z, LD and NC groups, each crown was fabricated with its respective material. Trueness was analyzed using 2-way ANOVA and Bonferroni tests. The Levene and Bonferroni tests were used to assess precision (α = 0.05). Results: Material (P < .001) and wetness (P < .001) significantly influenced trueness and precision. The mild and high subgroups revealed lower trueness and precision compared with the dry and low subgroups. The control, Z, and LD groups under dry and low wetness conditions showed better trueness compared with the NC group, but the materials tested had no significant precision discrepancies. Under mild wetness conditions, all the materials showed no significant trueness discrepancies. Under high wetness conditions, the LD group demonstrated the best trueness and precision. Conclusions: The restorative materials and surface wetness tested influenced scanning trueness and precision of the IOS assessed. Clinical significance: Dried surfaces are recommended to maximize the scanning accuracy values of the IOS tested. Overall, the presence of saliva and dental restorations can reduce the performance of the IOS tested.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.fundingtypeAPC financiada por la UCM
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationAgustín-Panadero R, Moreno DM, Pérez-Barquero JA, Fernández-Estevan L, Gómez-Polo M, Revilla-León M. Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy. J Dent. 2023 Jul;134:104521. doi: 10.1016/j.jdent.2023.104521
dc.identifier.doi10.1016/j.jdent.2023.104521
dc.identifier.essn1879-176X
dc.identifier.issn0300-5712
dc.identifier.officialurlhttps://doi.org/10.1016/j.jdent.2023.104521
dc.identifier.pmid37061118
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0300571223001070?via%3Dihub
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/37061118/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/108786
dc.journal.titleJournal of Dentistry
dc.language.isoeng
dc.page.initial104521
dc.publisherElsevier
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu615.46
dc.subject.cdu616-073.75
dc.subject.cdu616.314-089.843
dc.subject.keywordAccuracy
dc.subject.keywordDigital impression
dc.subject.keywordHumidity
dc.subject.keywordIntraoral scanner
dc.subject.keywordRestorative dental materials
dc.subject.keywordWetness
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmMateriales dentales
dc.subject.ucmDiagnóstico por imagen y medicina nuclear
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.subject.unesco3311.03 Instrumentos Para Odontología
dc.titleInfluence of type of restorative materials and surface wetness conditions on intraoral scanning accuracyen
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number134
dspace.entity.typePublication
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery9700c70b-34f2-4d6a-8e12-92587c9186fb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
J Dent. 2023 Jul;134:104521.pdf
Size:
13.07 MB
Format:
Adobe Portable Document Format
Description:
Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy.

Collections