dc.description.abstractEvaluation of the Meibomian glands morphology is becoming a popular assessment for dry eye. This evaluation is usually done by imaging the glands on the everted lids while they are illuminated with infrared light. Nowadays techniques to determine gland condition and dropout are based on grading scales with which meibography images are subjectively evaluated. In this work, we have measured the contrast of Meibomian gland images from ten subjects and for a range of wavelengths of the monochromatic illuminating light. We have used a xenon lamp and a monochromator as a light source, and a semi-automatic image processing technique for measuring the image contrast from 600 nm to 1050 nm. Contrast values inside glands are from 0.025 to 0.015 and between glands from 0.06 to 0.04. The greater values of contrast are obtained when Meibomian glands are illuminated with a wavelength close to 600 nm.en
dc.description.departmentDepto. de Optometría y Visión
dc.description.departmentSección Deptal. de Óptica (Óptica)
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía, Comercio y Empresa (España)
dc.description.sponsorshipFondo Europeo de Desarrollo Regional
dc.description.sponsorshipAgencia Española de Investigación
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/51193
dc.identifier.citationPeral A, Alonso J, Gomez-Pedrero JA. Effect of illuminating wavelength on the contrast of meibography images. OSA Contin. 2018;1(3):1041-54 doi: https://doi.org/10.1364/OSAC.1.001041
dc.identifier.doi10.1364/OSAC.1.001041
dc.identifier.issn2578-7519
dc.identifier.officialurlhttps://doi.org/10.1364/OSAC.1.001041
dc.identifier.relatedurlhttps://www.osapublishing.org/osac/abstract.cfm?uri=osac-1-3-1041
dc.identifier.urihttps://hdl.handle.net/20.500.14352/13092
dc.issue.number3
dc.journal.titleOSA Continuum
dc.language.isoeng
dc.page.final1054
dc.page.initial1041
dc.publisherOptica Publishing Group
dc.relation.projectIDDPI2016-75272-R
dc.rights.accessRightsopen access
dc.subject.cdu617.764
dc.subject.cdu611.846
dc.subject.cdu617.7-073.75
dc.subject.keywordContact lenses
dc.subject.keywordImage processing
dc.subject.keywordImage processing algorithms
dc.subject.keywordImaging techniques
dc.subject.keywordNonlinear spatial
dc.subject.keywordFiltering
dc.subject.keywordVisible light
dc.subject.ucmDiagnóstico por imagen y medicina nuclear
dc.subject.ucmAnatomía ocular
dc.subject.ucmTécnicas de la imagen
dc.subject.ucmÓptica no líneal
dc.subject.unesco3204.01 Medicina Nuclear
dc.subject.unesco2209.13 Óptica no lineal
dc.titleEffect of illuminating wavelength on the contrast of meibography imagesen
dc.typejournal article
dc.volume.number1
dspace.entity.typePublication
relation.isAuthorOfPublication2b3052fa-b98a-44f3-a982-f01bccb83c6a
relation.isAuthorOfPublicationf7b5b178-742c-418d-80d3-769a169f6dd9
relation.isAuthorOfPublication5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36
relation.isAuthorOfPublication.latestForDiscoveryf7b5b178-742c-418d-80d3-769a169f6dd9

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Pedrero_osac-1-3-1041.pdf
Size:
5.92 MB
Format:
Adobe Portable Document Format

Collections