Effect of illuminating wavelength on the contrast of meibography images
dc.contributor.author | Peral Cerda, María Asunción | |
dc.contributor.author | Alonso Fernández, José | |
dc.contributor.author | Gómez Pedrero, José Antonio | |
dc.date.accessioned | 2023-06-17T13:19:42Z | |
dc.date.available | 2023-06-17T13:19:42Z | |
dc.date.copyright | © 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement Received 6 Jul 2018; revised 5 Oct 2018; accepted 11 Oct 2018; published 13 Nov 2018 | |
dc.date.issued | 2018-11-15 | |
dc.description.abstract | Evaluation of the Meibomian glands morphology is becoming a popular assessment for dry eye. This evaluation is usually done by imaging the glands on the everted lids while they are illuminated with infrared light. Nowadays techniques to determine gland condition and dropout are based on grading scales with which meibography images are subjectively evaluated. In this work, we have measured the contrast of Meibomian gland images from ten subjects and for a range of wavelengths of the monochromatic illuminating light. We have used a xenon lamp and a monochromator as a light source, and a semi-automatic image processing technique for measuring the image contrast from 600 nm to 1050 nm. Contrast values inside glands are from 0.025 to 0.015 and between glands from 0.06 to 0.04. The greater values of contrast are obtained when Meibomian glands are illuminated with a wavelength close to 600 nm. | en |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.department | Sección Deptal. de Óptica (Óptica) | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Economía, Comercio y Empresa (España) | |
dc.description.sponsorship | Fondo Europeo de Desarrollo Regional | |
dc.description.sponsorship | Agencia Española de Investigación | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/51193 | |
dc.identifier.citation | Peral A, Alonso J, Gomez-Pedrero JA. Effect of illuminating wavelength on the contrast of meibography images. OSA Contin. 2018;1(3):1041-54 doi: https://doi.org/10.1364/OSAC.1.001041 | |
dc.identifier.doi | 10.1364/OSAC.1.001041 | |
dc.identifier.issn | 2578-7519 | |
dc.identifier.officialurl | https://doi.org/10.1364/OSAC.1.001041 | |
dc.identifier.relatedurl | https://www.osapublishing.org/osac/abstract.cfm?uri=osac-1-3-1041 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/13092 | |
dc.issue.number | 3 | |
dc.journal.title | OSA Continuum | |
dc.language.iso | eng | |
dc.page.final | 1054 | |
dc.page.initial | 1041 | |
dc.publisher | Optica Publishing Group | |
dc.relation.projectID | DPI2016-75272-R | |
dc.rights.accessRights | open access | |
dc.subject.cdu | 617.764 | |
dc.subject.cdu | 611.846 | |
dc.subject.cdu | 617.7-073.75 | |
dc.subject.keyword | Contact lenses | |
dc.subject.keyword | Image processing | |
dc.subject.keyword | Image processing algorithms | |
dc.subject.keyword | Imaging techniques | |
dc.subject.keyword | Nonlinear spatial | |
dc.subject.keyword | Filtering | |
dc.subject.keyword | Visible light | |
dc.subject.ucm | Diagnóstico por imagen y medicina nuclear | |
dc.subject.ucm | Anatomía ocular | |
dc.subject.ucm | Técnicas de la imagen | |
dc.subject.ucm | Óptica no líneal | |
dc.subject.unesco | 3204.01 Medicina Nuclear | |
dc.subject.unesco | 2209.13 Óptica no lineal | |
dc.title | Effect of illuminating wavelength on the contrast of meibography images | en |
dc.type | journal article | |
dc.volume.number | 1 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 2b3052fa-b98a-44f3-a982-f01bccb83c6a | |
relation.isAuthorOfPublication | f7b5b178-742c-418d-80d3-769a169f6dd9 | |
relation.isAuthorOfPublication | 5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36 | |
relation.isAuthorOfPublication.latestForDiscovery | f7b5b178-742c-418d-80d3-769a169f6dd9 |
Download
Original bundle
1 - 1 of 1