All-in-one silk-fibroin sustainable high performance electrochemical immunoplatforms: determination of the protein TIM-1 in cancer and allergy scenarios as a case study
| dc.contributor.author | Santiago, Sara | |
| dc.contributor.author | Cabrero Martín, Andrea | |
| dc.contributor.author | Serafín González-Carrato, Verónica | |
| dc.contributor.author | Pedrero Muñoz, María | |
| dc.contributor.author | Munõz Berbel, X. | |
| dc.contributor.author | Guirado, G. | |
| dc.contributor.author | Montero Calle, Ana | |
| dc.contributor.author | Pingarrón Carrazón, José Manuel | |
| dc.contributor.author | Barderas Manchado, Rodrigo | |
| dc.contributor.author | Campuzano Ruiz, Susana | |
| dc.date.accessioned | 2026-08-04T06:57:50Z | |
| dc.date.available | 2026-08-04T06:57:50Z | |
| dc.date.issued | 2026-04-20 | |
| dc.description.abstract | Silk fibroin (SF) is a natural biopolymer extracted from Bombyx mori that has emerged as a promising sustainable material in biosensing applications, especially because of its biodegradable and tunable properties. However, SF is still insufficiently explored in electrochemical biosensing. We present a novel all-in-one electrochemical immunoplatform based on a disposable electrode surface sequentially modified with Prussian Blue (PB) and SF. First, PB is electrodeposited, acting as a redox mediator that enhances signal amplification through its reversible electrochemistry and its low reduction potential for H2O2. The SF layer is here presented as a novel, biocompatible matrix for antibody immobilization that offers structural versatility and sustainability. This dual modification generates a synergistic ecofriendly functional interface that is stable at room temperature. Onto this innovative surface, we have developed a sandwich-type electrochemical immunosensor employing a biotinylated detector antibody and streptavidin–horseradish peroxidase (Strep-HRP) as the enzymatic label for the determination of T-cell immunoglobulin and mucin-domain containing protein 1 (TIM-1, also known as KIM-1 or HAVCR1), a relevant biomarker associated with cancer-related angiogenesis and poor prognosis, and, more recently, with allergenic episodes. The platform enabled sensitive and selective determination of TIM-1 in plasma samples from colorectal cancer (CRC) patients, and saliva samples from individuals undergoing allergic episodes, in which elevated TIM-1 levels were observed. A remarkable advantage of this immunosensor is its operational stability for up to 20 days at room temperature, eliminating the need for a cold chain. | |
| dc.description.department | Depto. de Química Analítica | |
| dc.description.faculty | Fac. de Ciencias Químicas | |
| dc.description.refereed | TRUE | |
| dc.description.sponsorship | Complutense University of Madrid | |
| dc.description.sponsorship | Ministerio de Ciencia e Innovación | |
| dc.description.sponsorship | Generalitat de Catalunya | |
| dc.description.status | pub | |
| dc.identifier.citation | S. Santiago*, A. Cabrero-Martín, V. Serafín, M. Pedrero, X. Munõz-Berbel, G. Guirado, A. Montero-Calle, J.M. Pingarrón, R. Barderas, S. Campuzano*. “All-in-one silk-fibroin sustainable high performance electrochemical immunoplatforms: determination of the protein TIM-1 in cancer and allergy scenarios as a case study”. Microchimica Acta 193 (2026) 322. https://doi.org/10.1007/s00604-026-08049-9 | |
| dc.identifier.doi | 10.1007/s00604-026-08049-9 | |
| dc.identifier.officialurl | https://doi.org/10.1007/s00604-026-08049-9 | |
| dc.identifier.relatedurl | https://link.springer.com/article/10.1007/s00604-026-08049-9 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/139028 | |
| dc.issue.number | 322 | |
| dc.journal.title | Microchimica Acta | |
| dc.language.iso | eng | |
| dc.publisher | Springer | |
| dc.relation.projectID | PID2022-136351OB-I00 | |
| dc.relation.projectID | PID2022-140307OB-I00 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-141293OB-I00/ES/MATERIALES FUNCIONALES POLIMERICOS ELECTRO- Y FOTOACTIVOS BASADOS EN INTERRUPTORES MOLECULARES/ | |
| dc.relation.projectID | PI20CIII/00019 | |
| dc.relation.projectID | PI23CIII/00027 | |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
| dc.rights.accessRights | restricted access | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject.cdu | 543 | |
| dc.subject.keyword | Silk fibroin | |
| dc.subject.keyword | Prussian blue | |
| dc.subject.keyword | All-in-one electrochemical immunoplatform | |
| dc.subject.keyword | Amperometric detection | |
| dc.subject.keyword | Plasma analysis | |
| dc.subject.keyword | Saliva | |
| dc.subject.ucm | Química analítica (Química) | |
| dc.subject.unesco | 2301.04 Análisis Electroquímico | |
| dc.title | All-in-one silk-fibroin sustainable high performance electrochemical immunoplatforms: determination of the protein TIM-1 in cancer and allergy scenarios as a case study | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 193 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 0fb5fd78-1ccd-4796-8515-817d82af17e4 | |
| relation.isAuthorOfPublication | 5b97e8ca-83fe-4ba2-9104-fc1c226f9aab | |
| relation.isAuthorOfPublication | 422f8844-54d1-4615-98e8-ef5a0c7e3519 | |
| relation.isAuthorOfPublication | 8808f99c-5f56-4562-839a-517626c76dad | |
| relation.isAuthorOfPublication | 21f5c8af-61fb-4d35-8e88-c01ee15a3bba | |
| relation.isAuthorOfPublication | 6945fb1e-9c48-459d-b994-e64328c3e79b | |
| relation.isAuthorOfPublication.latestForDiscovery | 0fb5fd78-1ccd-4796-8515-817d82af17e4 |