Ocular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements

dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorFernández Vidal, Ana María
dc.contributor.authorMéndez Hernández, Carmen Dora
dc.contributor.authorGarcía Sánchez, Julián
dc.date.accessioned2024-08-05T08:57:01Z
dc.date.available2024-08-05T08:57:01Z
dc.date.issued2006-08-08
dc.description.abstractPURPOSE. To establish correlations between intraocular pressure (IOP) measurements obtained with the ocular response analyzer (ORA) and the Goldmann applanation tonometer (GAT). The effects of central corneal thickness on the measures obtained were also examined. METHODS. This was a cross-sectional study. IOP was determined in 48 eyes of 48 patients with glaucoma In all patients, central corneal thickness (CCT) was measured by ultrasound pachymetry. RESULTS. ORA readings were consistently higher than GAT measurements (Goldmann-correlated IOP -IOP GAT mean difference, 7.2 ± 3.5 mm Hg; corneal-compensated IOP - IOP GAT mean difference, 8.3 ± 4.0 mm Hg) However, differences were not constant and increased with increasing IOP GAT readings, both with respect to Goldmann-correlated IOP (slope = 0.623, P < 0.0001) and corneal-compensated IOP (slope = 0.538, P < 0.0001). Both pressure measurements provided by the ORA showed significant correlation with CCT (CCT versus Goldmann-correlated IOP: r = 0.460, P = 0.001; CCT versus corneal-compensated IOP: r = 0.442, P = 0.001). No significant effects of corneal curvature or refraction on any of the pressures were observed. CONCLUSIONS. The ORA significantly overestimates IOP compared with the GAT. Differences between both sets of measures increase as the GAT-determined IOP increases. ORA readings seem to be affected by central corneal thickness. Copyright © Association for Research in Vision and Ophthalmology.
dc.description.departmentDepto. de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.sponsorshipInstituto de Salud Carlos III
dc.description.statuspub
dc.identifier.doi10.1167/IOVS.06-0158
dc.identifier.officialurlhttps://doi.org/10.1167/IOVS.06-0158
dc.identifier.relatedurlhttps://iovs.arvojournals.org/article.aspx?articleid=2124631
dc.identifier.urihttps://hdl.handle.net/20.500.14352/107375
dc.issue.number10
dc.journal.titleInvestigative Ophthalmology and Visual Science
dc.language.isoeng
dc.page.final4414
dc.page.initial4410
dc.publisherAssociation for Research in Vision and Ophthalmology
dc.relation.projectIDinfo:eu-repo/grantAgreement/ISCIII/Proyecto C03/13
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7
dc.subject.ucmOftalmología
dc.subject.unesco3201.09 Oftalmología
dc.titleOcular response analyzer versus Goldmann applanation tonometry for intraocular pressure measurements
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number47
dspace.entity.typePublication
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublicationa2727b5b-8b4b-4841-a173-75c1d2663a45
relation.isAuthorOfPublication533dd90f-2b34-4a5f-9cf8-ab8d19454edd
relation.isAuthorOfPublicationeff24faf-e089-4604-906d-bbd7f42be7f1
relation.isAuthorOfPublication.latestForDiscovery273a99c3-2c9f-4dd0-8939-b7ff3593124c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ORA_vs_GAT_IOP_Martinez-de-la-Casa_(2006)_Invest_Ophthalmol_Vis_Sci.pdf
Size:
114.99 KB
Format:
Adobe Portable Document Format

Collections