Evaluation and inter-observer analysis of retinography existing clinical classification system to categorize moderate retinopathies.
dc.conference.date | 30 septiembre - 3 octubre, 2009 | |
dc.conference.place | Portoroz, Eslovenia. | |
dc.conference.title | European association for Vision and Eye Research (EVER) | |
dc.contributor.author | Sánchez Ramos, Celia | |
dc.contributor.author | Wasfi, M. | |
dc.contributor.author | Bonnin Arias, Cristina Natalia | |
dc.contributor.author | Vinas Pena, M. | |
dc.contributor.author | Forlán, A. | |
dc.contributor.author | Molina Gómez, C. | |
dc.contributor.author | Chamorro Gutiérrez, E. | |
dc.date.accessioned | 2024-10-01T14:31:05Z | |
dc.date.available | 2024-10-01T14:31:05Z | |
dc.date.issued | 2009-10-03 | |
dc.description.abstract | PURPOSE: To evaluate existing validated systems to classify retinopathies, to determine the interobserver agreement level. METHODS: 55 retinographies (both gender >60 years old) were categorized following 3 stablished criteria: the International Classification and Grading System for ARM and AMD (BIRD), the Wisconsin Age-related Maculophathy Grading System (WISCONSIN) and the Clinical Age-related Maculophathy Staging System (CARMS). The categorizing was made by 2 experts in a blind, independent way. The goal of the doubled-classification-method, with changing order no randomised, was to reject the influence of the Velo effect. Inter-observer´s repeatability was checked as an agreement parameter between both Experts. RESULTS: CARMS system was chosen, since allows a global pathology classification. CARMS concordance obtained was 81.89% (expected= 57.39% kappa index = 0.57). Drusen concordance obtained was 87.27% (Expected= 60.31% kappa index = 0.68). Pigmentation concordance obtained was 76.36% (expected = 54.46% kappa index= 0.48). The reliability measured by Kappa index followed the rule: 0.80-1.00 (Excellent). 0.60-0.80 (Good) and 0.40-0.60 (Moderate). 0.20-0.40 (Low) < 0.20 (Bad) CONCLUSION: Existin Retinopathies classification systems can be improved, to solve the huge subjective level that they present. Kappa index obtained, shown medium concordance for the inter-observer analysis, except in Drusen case, dichotomy`s variable, which presented a good reliability. The worse behaviour of the Pigmentation´s variable respect to Drusen variable has to be noted. This has an important influence in the global CARMS reliability, so it makes this influence to fall down. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/108494 | |
dc.language.iso | eng | |
dc.rights.accessRights | open access | |
dc.subject.cdu | 611.843 | |
dc.subject.cdu | 617.751.9 | |
dc.subject.keyword | Retinography | |
dc.subject.keyword | Retinopathy | |
dc.subject.keyword | Moderate retinopathies | |
dc.subject.ucm | Óptica y optometría | |
dc.subject.ucm | Óptica geométrica e instrumental | |
dc.subject.ucm | Baja visión | |
dc.subject.ucm | Oftalmología | |
dc.subject.unesco | 2209 Óptica | |
dc.subject.unesco | 2209.15 Optometría | |
dc.subject.unesco | 3201.09 Oftalmología | |
dc.title | Evaluation and inter-observer analysis of retinography existing clinical classification system to categorize moderate retinopathies. | |
dc.title.alternative | Evaluación y análisis interobservador del sistema de clasificación clínica existente en retinografía para categorizar las retinopatías moderadas. | |
dc.type | conference poster | |
dc.type.hasVersion | AM | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 3360352c-552e-4aab-aa7d-ec88baa8079e | |
relation.isAuthorOfPublication | bd1d6d70-bafd-4ab0-a203-4b33b5d9cff1 | |
relation.isAuthorOfPublication.latestForDiscovery | 3360352c-552e-4aab-aa7d-ec88baa8079e |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Evaluation_and_inter_observed_analysis_of_retinography_existing_clinical_classification.pdf
- Size:
- 254.05 KB
- Format:
- Adobe Portable Document Format