Evaluation of blood pressure estimation models based on pulse arrival time

dc.contributor.authorBote Rosado, Jose Manuel
dc.contributor.authorRecas Piorno, Joaquín
dc.contributor.authorHermida Correa, Román
dc.date.accessioned2024-01-30T12:27:50Z
dc.date.available2024-01-30T12:27:50Z
dc.date.issued2020-03-05
dc.description.abstractSeveral models in the literature correlate blood pressure (BP) with the electrocardiogram (ECG) and photoplethysmogram (PPG) signals. These studies show substantial differences and have not been adequately compared. The MIMIC database, containing intrusive BP measures collected in a hospital setting, has been used to perform an extensive study of different models and variables extracted from the PPG and ECG signals. The best BP estimator model obtained is α/PAT2 + β HR + δ, where PAT is the Pulse Arrival Time and HR is the heart rate. This model allows the monitoring of fast BP trends and fluctuations. If absolute values of BP were required, the model would have to be calibrated with real BP measures. The model, with periodic recalibrations, meets the Association for the Advancement of Medical Instrumentation (AAMI) requirements for diastolic BP but not for systolic BP, for which the mean error is close to 8 mmHg.
dc.description.departmentDepto. de Arquitectura de Computadores y Automática
dc.description.facultyFac. de Informática
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.doi10.1016/j.compeleceng.2020.106616
dc.identifier.issn0045-7906
dc.identifier.officialurlhttps://www.sciencedirect.com/science/article/abs/pii/S0045790620304717?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/96480
dc.journal.titleComputers and Electrical Engineering
dc.language.isoeng
dc.publisherElsevier
dc.rightsAttribution-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nd/4.0/
dc.subject.keywordBlood Pressure (BP)
dc.subject.keywordPulse Arrival Time (PAT)
dc.subject.keywordPulse Transit Time (PTT)
dc.subject.keywordPulse Wave Velocity (PWV)
dc.subject.keywordCuff-less
dc.subject.keywordMIMIC database
dc.subject.keywordWearable
dc.subject.ucmBioinformática
dc.subject.unesco3304.17 Sistemas en Tiempo Real
dc.titleEvaluation of blood pressure estimation models based on pulse arrival time
dc.typejournal article
dc.volume.number84
dspace.entity.typePublication
relation.isAuthorOfPublication8e1e37da-1ec8-4b19-add3-20bbf6cb971c
relation.isAuthorOfPublicationfb90758b-c96c-4727-94ef-d4aa39c36fc4
relation.isAuthorOfPublication.latestForDiscovery8e1e37da-1ec8-4b19-add3-20bbf6cb971c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Preprint.pdf
Size:
1.37 MB
Format:
Adobe Portable Document Format

Collections