Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Inter-Rater Variability in the Evaluation of Lung Ultrasound in Videos Acquired from COVID-19 Patients

dc.contributor.authorLópez Herraiz, Joaquín
dc.contributor.authorFreijo Escudero, Clara
dc.contributor.authorotros, ...
dc.date.accessioned2023-06-22T11:14:02Z
dc.date.available2023-06-22T11:14:02Z
dc.date.issued2023-02
dc.descriptionArtículo firmado por 42 autores. This research was partially funded by CDTI (Spanish acronym: Centre for Industrial Technological Development), funding number COI-20201153. Partially supported by the Google Cloud Research Credits program with the funding number GCP19980904, by the project RTI2018-099118-A-I00 founded by MCIU/AEI/FEDER UE and by the European Commission-NextGenerationEU, through CSIC's Global Health Platform (PTI Salud Global).
dc.description.abstractLung ultrasound (LUS) allows for the detection of a series of manifestations of COVID-19, such as B-lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the performance of the test in a longitudinal or transverse orientation. Thirty-three physicians with advanced experience in LUS independently evaluated ultrasound videos previously acquired using the ULTRACOV system on 20 patients with confirmed COVID-19. For each patient, 24 videos of 3 s were acquired (using 12 positions with the probe in longitudinal and transverse orientations). The physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (kappa = 0.74), with only a fair IRR for the presence of individual B-lines (kappa = 0.36) and for confluent B-lines occupying < 50% (kappa = 0.26) and a moderate IRR in consolidations and B-lines > 50% (kappa = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR for LUS of COVID-19 patients may benefit from more standardized clinical protocols.
dc.description.departmentDepto. de Estructura de la Materia, Física Térmica y Electrónica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipCentre for Industrial Technological Development (CDTI)
dc.description.sponsorshipGoogle Cloud Research Credits program
dc.description.sponsorshipMCIU/AEI/FEDER UE
dc.description.sponsorshipEuropean Commission-NextGenerationEU, through CSIC's Global Health Platform (PTI Salud Global)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/78204
dc.identifier.doi10.3390/app13031321
dc.identifier.issn2076-3417
dc.identifier.officialurlhttp://dx.doi.org/10.3390/app13031321
dc.identifier.relatedurlhttps://www.mdpi.com/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/72232
dc.issue.number3
dc.journal.titleApplied sciences-basel
dc.language.isoeng
dc.publisherMDPI
dc.relation.projectIDCOI-20201153
dc.relation.projectIDGCP19980904
dc.relation.projectIDRTI2018-099118-A-I00
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu539.1
dc.subject.keywordComputed-tomography
dc.subject.ucmFísica nuclear
dc.subject.unesco2207 Física Atómica y Nuclear
dc.titleInter-Rater Variability in the Evaluation of Lung Ultrasound in Videos Acquired from COVID-19 Patients
dc.typejournal article
dc.volume.number13
dspace.entity.typePublication
relation.isAuthorOfPublicationff1ea731-78c3-4e37-a602-13cc8037ae8e
relation.isAuthorOfPublication.latestForDiscoveryff1ea731-78c3-4e37-a602-13cc8037ae8e

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LopezHerraiz01libre+CC.pdf
Size:
12.32 MB
Format:
Adobe Portable Document Format

Collections