OMERACT agreement and reliability study of ultrasonographic elementary lesions in osteoarthritis of the foot

dc.contributor.authorZabotti, Alen
dc.contributor.authorFilippou, Georgios
dc.contributor.authorCanzoni, Marco
dc.contributor.authorAdinolfi, Antonella
dc.contributor.authorPicerno, Valentina
dc.contributor.authorCarrara, Greta
dc.contributor.authorBalint, Peter
dc.contributor.authorBruyn, George A
dc.contributor.authorD'Agostino, Maria Antonietta
dc.contributor.authorDamjanov, Nemanja
dc.contributor.authorDelle Sedie, Andrea
dc.contributor.authorFilippucci, Emilio
dc.contributor.authorGonzález Fernández, María Luz
dc.contributor.authorHammer, Hilde Berner
dc.contributor.authorKarim, Zunaid
dc.contributor.authorMandl, Peter
dc.contributor.authorMoller, Ingrid
dc.contributor.authorMorales Lozano, María Rosario
dc.contributor.authorNaredo, Esperanza
dc.contributor.authorPorta, Francesco
dc.contributor.authorSakellariou, Garifallia
dc.contributor.authorTerslev, Lene
dc.contributor.authorScirè, Carlo Alberto
dc.contributor.authorIagnocco, Annamaria
dc.date.accessioned2025-10-20T16:17:27Z
dc.date.available2025-10-20T16:17:27Z
dc.date.issued2019-03-08
dc.description.abstractObjective To evaluate the level of agreement on ultrasonographic (US) lesions among highly experienced sonographers as well as the intraobserver and interobserver reliability of inflammatory and structural US lesions in patients with osteoarthritis (OA) of the foot. Methods After a systematic literature review, a Delphi survey was performed to test definitions of US lesions in OA of the foot, including inflammatory lesions (ie, synovial hypertrophy [SH], joint effusion [JE], power Doppler signal [PD]), and structural abnormalities (ie, cartilage damage [CD] and osteophytes). Subsequently, the reliability of US in assessing the aforementioned lesions was tested on static images as well as during a live exercise. Reliability was assessed by kappa analyses and prevalence-adjusted bias-adjusted kappa (PABAK) on a dichotomous and an ordinal scale. Results Intraobserver and interobserver reliability for SH and JE evaluated by binary scoring was good for both components, while the intraobserver reliability for semiquantitative scoring of SH ranged from moderate in the web-based exercise (PABAK 0.49) to good (PABAK 0.8) in the live exercise. Reliability for CD and PD assessments were respectively good and excellent in all exercises (ranged from PABAK 0.61 to 0.79 for CD and 0.88 to 0.95 for PD). The interobserver reliability for the semiquantitative scoring of osteophytes was fair in the live exercise (PABAK 0.36) and moderate in the static exercise (PABAK 0.60). Conclusions Consensual US definitions were found to be reliable for assessing inflammatory lesions in OA of the foot, while the use of US to assess structural damage requires further studies.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationZabotti A, Filippou G, Canzoni M, Adinolfi A, Picerno V, Carrara G, et al. OMERACT agreement and reliability study of ultrasonographic elementary lesions in osteoarthritis of the foot. RMD Open. 2019;5:e000795. https://doi.org/10.1136/rmdopen-2018-000795
dc.identifier.doi10.1136/rmdopen-2018-000795
dc.identifier.essn2056-5933
dc.identifier.officialurlhttps://dx.doi.org/10.1136/rmdopen-2018-000795
dc.identifier.relatedurlhttps://rmdopen.bmj.com/content/5/1/e000795
dc.identifier.urihttps://hdl.handle.net/20.500.14352/125135
dc.issue.number1
dc.journal.titleRMD Open
dc.language.isoeng
dc.page.final10
dc.page.initial1
dc.publisherBMJ Publishing Group
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.cdu616.718.7/.9
dc.subject.ucmPodología
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleOMERACT agreement and reliability study of ultrasonographic elementary lesions in osteoarthritis of the foot
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number5
dspace.entity.typePublication
relation.isAuthorOfPublication8d76d9b5-d300-4be3-9778-e5a4f13507fa
relation.isAuthorOfPublicationcc653fc6-43b2-4138-8e00-d600b69c0383
relation.isAuthorOfPublication.latestForDiscovery8d76d9b5-d300-4be3-9778-e5a4f13507fa

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
OMERACT_agreement_reliability.pdf
Size:
385.7 KB
Format:
Adobe Portable Document Format

Collections