Are palpation-guided interventional procedures on the adductor longus muscle safe? A cadaveric and sonographic investigation.

dc.contributor.authorSantamaría-Le Pera, Javier
dc.contributor.authorValera Garrido, Fermín
dc.contributor.authorValderrama Canales, Francisco José
dc.contributor.authorMinaya Muñoz, Francisco
dc.contributor.authorHerrero, Pablo
dc.contributor.authorLapuente Hernández, Diego
dc.date.accessioned2025-11-21T10:38:13Z
dc.date.available2025-11-21T10:38:13Z
dc.date.issued2025-02-07
dc.description.abstractPurpose: The main objective was to study the anatomy of the adductor longus by ultrasound and cadaveric dissection, correlate the findings with the different approaches described, and evaluate the feasibility of defining a "safe window" for interventional musculoskeletal procedures. Methods: The anatomical study was performed on six cadaveric pieces, while ultrasound evaluations were performed on both lower limbs of 26 subjects (n = 52). Ultrasound variables included the number of saphenous veins, the location of the saphenous vein in relation to the proximal myotendinous junction, the number of vessels within or superficial to the adductor longus, and the distance between the dermis and the inferior border of the adductor longus to the anterior branch of the obturator nerve. Results: Key anatomic risk factors identified in cadavers included the great saphenous vein, the anterior branch of the obturator nerve, and the vascular network traversing the adductor longus. Ultrasound findings revealed that 91.4% of cases had at least one vessel at the proximal myotendinous junction in the cross-sectional area, almost 60% showed two to five vessels within the thickness of the muscle, and the anterior branch of the obturator nerve was located at a mean depth of 3.63-3.93 cm. Conclusions: It was not possible to define a "safe" approach area without the risk of damaging any neurovascular bundle due to the high anatomical variability both in number and in the route of these along the adductor longus. Therefore, the use of ultrasound to guide any interventional musculoskeletal procedure is highly recommended. Keywords: Adductor longus muscle; Cadaver; Interventional musculoskeletal procedures; Sonography; Ultrasound. Conflict of interest statement Declarations. Ethical approval: Not applicable. The donation of human bodies intrinsically implies the donor’s informed consent for the use of his or her remains in educational and research activities. In addition, the ultrasound evaluations performed as part of this study on healthy living subjects, being observational in nature, did not require additional ethical approval. Informed content: All subjects who participated in the study signed an informed consent form. Competing interests: The authors declare no competing interests.
dc.description.departmentDepto. de Anatomía y Embriología
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationSantamaría-Le Pera J, Valera-Garrido F, Valderrama-Canales FJ, Minaya-Muñoz F, Herrero P, Lapuente-Hernández D. Are palpation-guided interventional procedures on the adductor longus muscle safe? A cadaveric and sonographic investigation. Surg Radiol Anat. 2025 Feb 7;47(1):74. doi: 10.1007/s00276-025-03567-2. PMID: 39920288; PMCID: PMC11805763.
dc.identifier.doi10.1007/s00276-025-03567-2
dc.identifier.essn1279-8517
dc.identifier.issn0930-1038
dc.identifier.officialurlhttps://doi.org/10.1007/s00276-025-03567-2
dc.identifier.pmid39920288
dc.identifier.relatedurlhttps://link.springer.com/article/10.1007/s00276-025-03567-2
dc.identifier.relatedurlhttps://pubmed.ncbi.nlm.nih.gov/39920288/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/126323
dc.issue.number1
dc.journal.titleSurgical Radiologic Anatomy
dc.language.isoeng
dc.page.final8
dc.page.initial1
dc.publisherSpringer
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu611
dc.subject.keywordAdductor longus muscle
dc.subject.keywordCadaver
dc.subject.keywordInterventional musculoskeletal procedures
dc.subject.keywordSonography
dc.subject.keywordUltrasound
dc.subject.ucmAnatomía
dc.subject.unesco2410.13 Anatomía Topográfica
dc.titleAre palpation-guided interventional procedures on the adductor longus muscle safe? A cadaveric and sonographic investigation.
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number47
dspace.entity.typePublication
relation.isAuthorOfPublication4be20c83-c907-4e71-b8cf-fd9950ba48e7
relation.isAuthorOfPublication.latestForDiscovery4be20c83-c907-4e71-b8cf-fd9950ba48e7

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Are_palpation_guided_interventional_procedures_adductor_longus_muscle_safe_cadaveric_sonographic_investigation.pdf
Size:
936.09 KB
Format:
Adobe Portable Document Format

Collections