Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Visual quality and patient satisfaction with a trifocal intraocular lens and its new toric version

dc.contributor.authorRementería Capelo, Laureano A
dc.contributor.authorContreras Martín, Inés
dc.contributor.authorGarcía Pérez, Jorge L.
dc.contributor.authorBlázquez Sánchez, Vanesa
dc.contributor.authorRuiz Alcocer, Javier
dc.date.accessioned2023-06-16T15:18:41Z
dc.date.available2023-06-16T15:18:41Z
dc.date.issued2019-11
dc.descriptionReceived 26 March 2019, Revised 13 June 2019, Accepted 17 June 2019, Available online 3 October 2019.
dc.description.abstractPurpose: To assess and compare the visual quality and subjective outcomes of a trifocal spherical intraocular lens (IOL) and its new toric version. Setting: Clínica Rementería, Madrid, Spain. Design: Prospective case series. Methods: Patients had bilateral implantation of the AcrySof IQ PanOptix spherical or toric IOL. Three months postoperatively, monocular and the binocular uncorrected and corrected distance, intermediate, and near visual acuities; binocular defocus curves; and binocular contrast sensitivity function (CSF) were assessed. Patient satisfaction was evaluated with the Catquest 9SF questionnaire. Results: The study comprised 250 eyes (166 with spherical IOL; 84 with toric IOL) of 125 patients. Both groups had good monocular visual acuity at all distances with no statistically significant differences between groups. The mean monocular uncorrected acuity in the spherical group was 0.06 logarithm of the minimum angle of resolution (logMAR) ± 0.07 (SD), 0.20 ± 0.10 logMAR, and 0.05 ± 0.07 logMAR for far, intermediate, and near, respectively, and in the toric group, 0.07 ± 0.10 logMAR, 0.23 ± 0.20 logMAR, and 0.07 ± 0.12 logMAR, respectively. Defocus curves showed a visual acuity of 0.1 logMAR or better between −2.5 diopters (D) and +0.5 D with no differences between groups. The CSF values were within normal ranges with both IOLs. The questionnaire showed high rates of patient satisfaction with no differences between groups. Conclusions: The visual outcomes with the 2 IOLs were similar. With optimum implantation and alignment, the trifocal toric IOL seems to provide visual quality and patient satisfaction that is equivalent to that with the nontoric version with the same platform.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/60763
dc.identifier.doi10.1016/j.jcrs.2019.06.014
dc.identifier.issn1873-4502
dc.identifier.officialurlhttps://doi.org/10.1016/j.jcrs.2019.06.014
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0886335019304882
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6298
dc.issue.number11
dc.journal.titleJournal of cataract and refractive surgery
dc.language.isoeng
dc.page.final1590
dc.page.initial1584
dc.publisherElsevier
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.7.066.32
dc.subject.cdu617.751
dc.subject.keywordVisual quality
dc.subject.keywordIntraocular lens
dc.subject.keywordIOLs
dc.subject.keywordTrifocal intraocular lens
dc.subject.keywordToric lens
dc.subject.ucmCirugía
dc.subject.ucmLentes de contacto
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3213 Cirugía
dc.subject.unesco3311.11 Instrumentos ópticos
dc.titleVisual quality and patient satisfaction with a trifocal intraocular lens and its new toric version
dc.typejournal article
dc.volume.number45
dspace.entity.typePublication
relation.isAuthorOfPublicationb7f0bd69-3ee7-4f85-9053-89850d60238f
relation.isAuthorOfPublicatione7b1d7df-7032-4d5e-b1c5-ac67a61a8b1c
relation.isAuthorOfPublication.latestForDiscoveryb7f0bd69-3ee7-4f85-9053-89850d60238f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
JavierRAlcocer_Visualquality-2019_1-s2.0-S0886335019304882-main.pdf
Size:
683.19 KB
Format:
Adobe Portable Document Format

Collections