Equivalence of two optical quality metrics to predict visual acuity of multifocal pseudophakic patients

dc.contributor.authorArmengol Cebrian, Jesús
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorVega Lerin, Fidel
dc.contributor.authorAltemir Gómez, Irene
dc.contributor.authorMillán García Varela, María Sagrario
dc.date.accessioned2023-06-16T15:16:50Z
dc.date.available2023-06-16T15:16:50Z
dc.date.issued2020
dc.descriptionReceived 21 Jan 2020; revised 1 Apr 2020; accepted 3 Apr 2020
dc.description.abstractThis article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad de España (MINECO)
dc.description.statusinpress
dc.eprint.idhttps://eprints.ucm.es/id/eprint/59959
dc.identifier.doi10.1364/BOE.388531
dc.identifier.issn2156-7085
dc.identifier.officialurlhttps://doi.org/10.1364/BOE.388531
dc.identifier.relatedurlhttps://www.osapublishing.org/boe/home.cfm
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6151
dc.journal.titleBiomedical Optics Express
dc.language.isoeng
dc.publisherOSA Publishing
dc.relation.projectIDDPI2016-76019-R
dc.rightsAtribución-NoComercial 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by-nc/3.0/es/
dc.subject.cdu681.73
dc.subject.cdu617.7-089.243
dc.subject.cdu617.741-004.1
dc.subject.cdu617.75
dc.subject.keywordVisual acuity
dc.subject.keywordPseudophakic patients
dc.subject.keywordMultifocal pseudophakic
dc.subject.keywordVisual quality
dc.subject.keywordIntraocular lenses
dc.subject.keywordIOLs
dc.subject.keywordMultifocal intraocular lenses
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco2209 Óptica
dc.titleEquivalence of two optical quality metrics to predict visual acuity of multifocal pseudophakic patients
dc.typejournal article
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nuria Garzon_Biomedical optics express 2020.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format
Collections