A dual 1H/19F birdcage coil for small animals at 7 T MRI
| dc.contributor.author | Palmira Villa Valverde | |
| dc.contributor.author | Rodríguez Ramírez De Arellano, Ignacio | |
| dc.contributor.author | Daniel Padró | |
| dc.contributor.author | Marina Benito | |
| dc.contributor.author | Carlos Ernesto Garrido Salmón | |
| dc.contributor.author | Ruiz-Cabello Osuna, Jesús | |
| dc.date.accessioned | 2026-02-28T10:16:00Z | |
| dc.date.available | 2026-02-28T10:16:00Z | |
| dc.date.issued | 2019 | |
| dc.description.abstract | Objective: Given the growing interest in fluorine, it is necessary to develop new multi-tuned RF coils. Therefore, our objective is to design a simple and versatile double-tuned RF coil that can be used as a transmitter and receiver double-tuned coil (1H and 19F) or as transmitter-only double-tuned coil. Materials and methods: A high-pass eight-element birdcage coil was built for 1H and 19F for a 7 T scanner. PIN diodes and cable traps to block unwanted common mode currents in cables were introduced to confer more flexibility to the coil. S-parameters and quality factor were measured in workbench and signal to noise ratio as well as signal intensity profiles in imaging experiments. Results: Bench measurements show S11 values less than - 33 dB, S21 lower than - 13 dB and quality factors ratio of the order of 1.8 that are in agreement with good performances of a RF coil, as well as values of - 39 dB for 19F and - 30 dB for 1H as good detuning values. Signal intensity profiles prove excellent homogeneity at 1H and 19F. Discussion: We present a simple structure of a double-tuned high-pass birdcage coil tuned to 1H and 19F that shows a great uniformity and sensitivity for 19F. | |
| dc.description.department | Depto. de Química en Ciencias Farmacéuticas | |
| dc.description.faculty | Fac. de Farmacia | |
| dc.description.refereed | TRUE | |
| dc.description.sponsorship | Ministerio de Economía, Industria y Competitividad (España) | |
| dc.description.sponsorship | Comunidad de Madrid | |
| dc.description.sponsorship | European Commission | |
| dc.description.status | pub | |
| dc.identifier.citation | Villa-Valverde P, Rodríguez I, Padró D, et al. A dual 1H/19F birdcage coil for small animals at 7 T MRI. Magn Reson Mater Phy 2019;32:79–87. https://doi.org/10.1007/s10334-018-00733-z | |
| dc.identifier.doi | 10.1007/s10334-018-00733-z | |
| dc.identifier.officialurl | https://doi.org/10.1007/s10334-018-00733-z | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/133572 | |
| dc.issue.number | 1 | |
| dc.journal.title | Magnetic Resonance Materials in Physics, Biology and Medicine | |
| dc.language.iso | eng | |
| dc.page.final | 87 | |
| dc.page.initial | 79 | |
| dc.publisher | SpringerLink | |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//SAF2017-84494-C2-R | |
| dc.relation.projectID | info:eu-repo/grantAgreement/CAM//B2017-BMD3731 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/CAM//B2017-BMD3875 | |
| dc.rights.accessRights | restricted access | |
| dc.subject.cdu | 615 | |
| dc.subject.keyword | Double-tuned | |
| dc.subject.keyword | Fluorine | |
| dc.subject.keyword | High-pass birdcage | |
| dc.subject.keyword | PIN diode | |
| dc.subject.ucm | Ciencias | |
| dc.subject.ucm | Ciencias Biomédicas | |
| dc.subject.unesco | 24 Ciencias de la Vida | |
| dc.title | A dual 1H/19F birdcage coil for small animals at 7 T MRI | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 32 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 85f8ae35-f650-415c-bd71-06c07ee772b4 | |
| relation.isAuthorOfPublication | de9b6685-e822-4ea8-9ff8-5841cd12adc8 | |
| relation.isAuthorOfPublication.latestForDiscovery | 85f8ae35-f650-415c-bd71-06c07ee772b4 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- A dual 1 H/19 F birdcage coil for small animals at 7 T MRI_finalpdf
- Size:
- 766.8 KB
- Format:
- Adobe Portable Document Format