Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation

dc.contributor.authorMartínez Alberquilla, Irene
dc.contributor.authorSvensson, Saga
dc.contributor.authorRuiz Alcocer, Javier
dc.contributor.authorMadrid Costa, David
dc.contributor.authorDominguez-Vicent, Alberto
dc.contributor.authorPriya Venkataraman, Abinaya
dc.date.accessioned2024-10-29T13:12:48Z
dc.date.available2024-10-29T13:12:48Z
dc.date.issued2024-09-27
dc.description.abstractThe repeatability of two biometers (Lenstar-LS900 and Eyestar-900) to measure ocular parameters and intraocular lens (IOL) power calculation, and their agreement were evaluated. 134 eyes of 134 participants were measured thrice with each biometer. Axial length (AL), anterior chamber depth (ACD), lens thickness (LT) and keratometry (K) were evaluated. The IOL power was calculated using different formulas. The repeatability limit (RLimit), the mean differences (MD) and the limits of agreement (LoA) were calculated. The RLimits for all parameters were higher with Lenstar compared to Eyestar. RLimits were lower than 0.50 D except for Barrett Universal II (0.54 D) and Haigis (0.51 D) formulas with the Lenstar. Mean differences were lower than 0.01 mm for AL, ACD and LT, and lower than 0.03 D for K. MD ranged from 0 to 0.02 D for all formulas except for Barrett and Hill. When dividing the sample into subgroups (short, normal and long eyes), the MDs were similar for the IOL power and were lower than 0.03 D, except for the Barrett and Hill formulas. Both biometers provide repeatable biometry and IOL power calculations. The LoA interval for the IOL power calculation was between 0.75 and 1.50D, which was similar among the subgroups.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.fundingtypePagado por el autor
dc.description.refereedTRUE
dc.description.sponsorshipKarolinska Institute
dc.description.statuspub
dc.identifier.citationAlberquilla, I.M., Svensson, S., Ruiz-Alcocer, J. et al. Evaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation. Sci Rep 14, 22151 (2024). https://doi.org/10.1038/s41598-024-73206-0
dc.identifier.doi10.1038/s41598-024-73206-0
dc.identifier.officialurlhttps//doi.org/10.1038/s41598-024-73206-0
dc.identifier.urihttps://hdl.handle.net/20.500.14352/109699
dc.issue.number22151
dc.journal.titleNature
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subject.cdu617.7-089.243
dc.subject.keywordRepeatability
dc.subject.keywordAgreement
dc.subject.keywordIOL power calculation
dc.subject.keywordLenstar
dc.subject.keywordEyestar
dc.subject.ucmÓptica y optometría
dc.subject.unesco2209.15 Optometría
dc.titleEvaluation of repeatability and agreement of two optical biometers for intraocular lens power calculation
dc.typejournal article
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication7d72044d-983a-4b5a-abab-6a5e45396824
relation.isAuthorOfPublicatione7b1d7df-7032-4d5e-b1c5-ac67a61a8b1c
relation.isAuthorOfPublication383ca857-3af5-4787-8717-d278082d1d13
relation.isAuthorOfPublication.latestForDiscovery7d72044d-983a-4b5a-abab-6a5e45396824