Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Dual Internal Standards with Metals and Molecules for MALDI Imaging of Kidney Lipids

dc.contributor.authorAboulmagd, Sarah
dc.contributor.authorEsteban Fernández, Diego
dc.contributor.authorMoreno Gordaliza, María Estefanía
dc.contributor.authorNeumann, Boris
dc.contributor.authorEl-Khatib, A.H.
dc.contributor.authorLázaro Fernández, Alberto
dc.contributor.authorTejedor Jorge, Alberto
dc.contributor.authorGómez Gómez, María Milagros
dc.contributor.authorLinscheid, Michael W.
dc.date.accessioned2023-06-17T22:42:23Z
dc.date.available2023-06-17T22:42:23Z
dc.date.issued2017
dc.description.abstractThe quest for internal standards useful in MALDI imaging studies goes on to get not only lateral distribution but also reliable relative quantitative information. We developed a method based on application of matrix and dual internal standards to allow intra- and intersample normalization of lipids intensities in kidney sections of control and cisplatin-treated Wistar rats. An inkjet printer was used to deposit a custom-prepared ink with DHB as MALDI matrix, a primary lipids-based internal standard, and a spiked lanthanide as a secondary internal standard. We applied different laser energy and varied the amounts of matrix-internal standards mixture to evaluate the normalization potential of the internal standards. Successful correction of intensity artifacts caused by instrumental drifts was possible, but not those resulting from uneven matrix application. ICP-MS absolute quantification of the lanthanide in the printed layer ensured the reproducibility of the matrix and internal standards application with RSD of 10−15%. Internal standard-normalized data allowed intrasample modification of the MALDI image to make it compatible with the optical image. Normalization to internal standards corrected a 2-fold difference in lipids intensity, which allowed a meaningful comparison of tissue lipids in control and cisplatin-treated kidneys. More importantly, normalization of lipid relative abundances based on the same adduct type (H+ , Na+ , and K+ ) for analyte and internal standard corrected for different ionization efficiencies showing a realistic signal level and enabling reliable comparison of different samples on relative quantitative basis.en
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/55255
dc.identifier.citationAboulmagd, S., Esteban Fernández, D., Moreno Gordaliza, E. et al. «Dual Internal Standards with Metals and Molecules for MALDI Imaging of Kidney Lipids». Analytical Chemistry, vol. 89, n.o 23, diciembre de 2017, pp. 12727-34. DOI.org (Crossref), https://doi.org/10.1021/acs.analchem.7b02819.
dc.identifier.doi10.1021/acs.analchem.7b02819
dc.identifier.issn0003-2700
dc.identifier.officialurlhttps//doi.org/10.1021/acs.analchem.7b02819
dc.identifier.relatedurlhttps://pubs.acs.org/doi/pdf/10.1021/acs.analchem.7b02819
dc.identifier.urihttps://hdl.handle.net/20.500.14352/18777
dc.journal.titleAnalytical chemistry
dc.language.isoeng
dc.page.final12734
dc.page.initial12727
dc.publisherACS
dc.rights.accessRightsrestricted access
dc.subject.cdu543
dc.subject.keywordSpectrometry
dc.subject.keywordMass
dc.subject.keywordMatrix-Assisted Laser Desorption-Ionization
dc.subject.keywordMass Spectrometry
dc.subject.keywordImaging mass
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.titleDual Internal Standards with Metals and Molecules for MALDI Imaging of Kidney Lipidsen
dc.typejournal article
dc.volume.number89
dspace.entity.typePublication
relation.isAuthorOfPublicationf9bc6d05-8d93-454c-a5fd-c502df9c2a7e
relation.isAuthorOfPublication6847c054-afab-4cd8-b7e2-fce87656bbd4
relation.isAuthorOfPublicationa74445b1-90f5-41a5-9601-220d472d8d63
relation.isAuthorOfPublication98fd9b6f-b112-42da-b0f7-b9ec1a9e748b
relation.isAuthorOfPublication.latestForDiscovery6847c054-afab-4cd8-b7e2-fce87656bbd4

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
publicado(Milagros 2).pdf
Size:
2.3 MB
Format:
Adobe Portable Document Format

Collections