Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope

Loading...
Thumbnail Image

Full text at PDC

Publication date

2024

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Lippincott Williams & Wilkins. Wolters Kluwer
Citations
Google Scholar

Citation

Carpena-Torres C, Ferrando E, García-García C, Romaguera M, Huete-Toral F, Carracedo G. In Vitro Evaluation of Soft Contact Lens Wettability With a Nonmodified Commercial Videokeratoscope. Eye Contact Lens. 2024 Apr 1;50(4):177-182. doi: 10.1097/ICL.0000000000001074. Epub 2024 Feb 1. PMID: 38305377.

Abstract

Purpose: To evaluate a new in vitro technique for measuring soft contact lens wettability using a nonmodified commercial videokeratoscope, the Medmont E300. To this end, the capability of different artificial tears containing hyaluronic acid (HA) to improve soft contact lens wettability in vitro was investigated. Methods: An experimental in vitro study was conducted to assess the wetting properties of three artificial tears containing different concentrations of HA (0.1%, 0.2%, and 0.3%) on soft contact lenses. A saline solution was used as the control. For each solution, 15 hydrogel (Ocufilcon D) contact lenses and 15 silicone-hydrogel (Somofilcon A) contact lenses were evaluated. The in vitro wettability of the lenses was measured using the Medmont E300 with a self-developed technique, which involved measuring the tear film surface quality (TFSQ) mean, TFSQ area, TFSQ central, and TFSQ inferior. Results: Compared with the saline solution, all the concentration of HA (0.1%, 0.2%, and 0.3%) improved the in vitro wettability of both soft contact lenses by decreasing their TFSQ mean and TFSQ area (P<0.05). Regression models revealed an exponential relationship between contact lens wettability and the concentration of HA for both soft contact lenses (R>0.5, P<0.05). Furthermore, the hydrogel contact lens presented a wetter surface than the silicone-hydrogel contact lens (P<0.05). Conclusions: The measurement of in vitro wettability of soft contact lenses with a nonmodified Medmont E300 seems to be a useful technique to evaluate the wetting properties of contact lens products.

Research Projects

Organizational Units

Journal Issue

Description

Keywords

Collections