Comparison of 2 medium cutoff dialyzers versus on‐line hemodiafiltration regarding depurative ability and albumin loss: An uncontrolled clinical research

dc.contributor.authorMartínez‐Miguel, Patricia
dc.contributor.authorGimena Muñoz, Rocío
dc.contributor.authorBarrionuevo González, Marta
dc.contributor.authorLópez‐Ongil, Susana
dc.contributor.authorMoro Sánchez, María Ángeles
dc.contributor.authorLizasoaín Hernández, Ignacio
dc.contributor.authorDiego Rodríguez‐Puyol
dc.contributor.authorGarcía Segura, Juan Manuel
dc.date.accessioned2024-01-22T16:30:25Z
dc.date.available2024-01-22T16:30:25Z
dc.date.issued2022
dc.descriptionACKNOWLEDGMENTS The Ethics Committee for Research involving medical products of the Hospital Universitario Príncipe de Asturias, at its meeting on 23 February 2021, and after evaluating the proposal by the sponsor regarding the specified study, considered issuing a FAVORABLE OPINION for the study to be carried out. FUNDING INFORMATION This work was partially financed by Nipro.
dc.description.abstractAbstract Background Hemodialysis (HD) techniques that best remove molecules in the middle to high molecular weight range are on-line hemodiafiltration (OL-HDF) and HD with medium cut-off (MCO) membranes. The aim of this study was to compare efficacy and safety of OL-HDF with FxCordiax HDF 800™, with HD with 2 MCO dialyzers: Theranova 500® and the new Elisio 21HX™ dialyzer. Methods Fourteen patients following treatment with OL-HDF using FxCordiax HDF 800™ were randomized to receive a consecutive 1-week HD treatment with Theranova 500® and Elisio 21HX™.The reduction rate (RR) of differently sized molecules was compared, as well as the variation rate in molecules smaller than 1000, detected by nuclear magnetic resonance based chemometrics (metabolomics). Albumin loss in dialysate was quantified. Results Lower RRs were found for molecules around 20 000 with Elisio 21HX™ compared to OL- HDF (RR prolactin 58.5% versus 66.7%, p = 0.034; RR Kappa light chain 63.1% versus 71.8%, p = 0.010). Albumin loss per session was higher with Theranova 500® than with OL-HDF and with Elisio 21HX™ (2249.9 ± 714.1 mg, 815.2 ± 474.0 mg, 442.9 ± 135.9 mg, p < 0.001, respectively). Metabolomic studies suggested, by semi-quantitative analysis, a greater depurative capacity of OL-HDF, followed by Elisio 21HX™, and then Theranova 500®. Conclusions In this study, HD with Theranova 500® has proven to be very similar in efficacy to OL-HDF, although with a significantly higher albumin loss. HD with Elisio 21HX™ resulted in lower removal of molecules around 20 000 compared to OL-HDF, with no significant difference compared to Theranova 500®, and with less albumin loss than Theranova 500®.
dc.description.departmentDepto. de Bioquímica y Biología Molecular
dc.description.facultyFac. de Ciencias Biológicas
dc.description.refereedTRUE
dc.description.sponsorshipNIPRO (España)
dc.description.statuspub
dc.identifier.citationMartínez‐Miguel, Patricia, et al. «Comparison of 2 Medium Cutoff Dialyzers versus On‐line Hemodiafiltration Regarding Depurative Ability and Albumin Loss: An Uncontrolled Clinical Research». Artificial Organs, vol. 47, n.o 3, marzo de 2023, pp. 589-94. https://doi.org/10.1111/aor.14466.
dc.identifier.doi10.1111/aor.14466
dc.identifier.essn1525-1594
dc.identifier.issn0160-564X
dc.identifier.officialurlhttps://doi.org/10.1111/aor.14466
dc.identifier.urihttps://hdl.handle.net/20.500.14352/94494
dc.issue.number3
dc.journal.titleArtificial Organs
dc.language.isoeng
dc.page.final594
dc.page.initial589
dc.publisherWiley
dc.rights.accessRightsrestricted access
dc.subject.cdu577.112
dc.subject.keywordAlbumine
dc.subject.keywordExpanded hemodialysis
dc.subject.keywordMedium cut-off dialyser
dc.subject.keywordOn-line hemodiafiltration
dc.subject.keywordUremic toxins
dc.subject.ucmBioquímica (Biología)
dc.subject.unesco2403 Bioquímica
dc.titleComparison of 2 medium cutoff dialyzers versus on‐line hemodiafiltration regarding depurative ability and albumin loss: An uncontrolled clinical research
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number47
dspace.entity.typePublication
relation.isAuthorOfPublication101895d7-7d3b-4f8b-a049-f6f19020e0b0
relation.isAuthorOfPublication22bd5da1-89a4-434c-8dca-7c2f8db2b710
relation.isAuthorOfPublication04d2e613-e29d-4b54-90f3-c5a68815f4de
relation.isAuthorOfPublication.latestForDiscovery04d2e613-e29d-4b54-90f3-c5a68815f4de

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Comparison_of_2_medium_cutoff_dialyzers.pdf
Size:
704.52 KB
Format:
Adobe Portable Document Format

Collections