Determination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs

dc.contributor.authorOrtiz Gutiérrez, Jorge
dc.contributor.authorPortero Fuentes, Miriam
dc.contributor.authorFominaya García, Hernán Luis
dc.contributor.authorMínguez Pereira, Elena
dc.contributor.authorMartín Carrasco, Laura
dc.contributor.authorGarcía Pérez, Enrique
dc.contributor.authorDaza González, María Ángeles
dc.date.accessioned2025-09-10T11:14:04Z
dc.date.available2025-09-10T11:14:04Z
dc.date.issued2025
dc.descriptionJustificación de autores: Jorge Ortiz-Gutiérrez: Writing – review & editing, Writing – original draft, Methodology, Investigation, Formal analysis, Conceptualization. Miriam Portero-Fuentes: Writing – review & editing, Writing – original draft, Validation, Supervision, Formal analysis. Hernán Fominaya García: Writing – review & editing, Writing – original draft, Supervision, Formal analysis. Elena Mínguez-Pereira: Investigation. Laura Martín-Carrasco: Investigation. Enrique García Pérez: Investigation. María Ángeles Daza: Writing – review & editing, Writing – original draft, Supervision, Formal analysis.
dc.description.abstractRenal Resistive Index (RRI) and Renal Pulsatility Index (RPI) are currently used in the diagnosis of ureteral obstruction, early diagnosis and follow-up of acute kidney injury, assessment of chronic kidney disease, and evaluation of transplanted kidneys. However, their inter-observer and inter-scanner variability has not been investigated in dogs, limiting the accuracy and clinical applicability of these indices. The objectives of this cross-sectional observational prospective study were to assess the inter-observer and inter-scanner variability of RRI and RPI and to determine whether operator experience influences measurement accuracy. RRI and RPI were measured in the left kidney of 10 client-owned dogs by four different operators with varying levels of experience, using two different ultrasound scanners. The intraclass correlation coefficient (ICC) between the two ultrasound scanners for both RRI and RPI were good to excellent in all four observers (ICC > 0.75 and p < 0.05). Similarly, a good to excellent correlation coefficient was observed between the measurements of the four operators for both indices across each ultrasound scanner (ICC > 0.75 and p < 0.05). These findings indicate that RRI and RPI are feasible and reproducible measurements with good inter-scanner and inter-observer agreement, regardless of operator experience. However, achieving high reproducibility requires adequate training and the use of a standardized protocol with strict but adaptable settings tailored to each patient's characteristics.
dc.description.departmentDepto. de Medicina y Cirugía Animal
dc.description.facultyFac. de Veterinaria
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationOrtiz-Gutiérrez, J., Portero-Fuentes, M., Fominaya García, H., Mínguez-Pereira, E., Martín-Carrasco, L., García Pérez, E., & Daza, M. Á. (2025). Determination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs. Research in veterinary science, 196, 105882. Advance online publication. https://doi.org/10.1016/j.rvsc.2025.105882
dc.identifier.doi10.1016/j.rvsc.2025.105882
dc.identifier.essn1532-2661
dc.identifier.issn0034-5288
dc.identifier.officialurlhttps://doi.org/10.1016/j.rvsc.2025.105882
dc.identifier.pmid40915192
dc.identifier.urihttps://hdl.handle.net/20.500.14352/123815
dc.issue.numberNoviembre
dc.journal.titleResearch in Veterinary Science
dc.language.isoeng
dc.publisherElsevier
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu636.09
dc.subject.keywordÍndice de resistencia
dc.subject.keywordÍndice e de pulsatilidad
dc.subject.keywordVariabilidad
dc.subject.keywordPerros
dc.subject.keywordRiñón
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco3109 Ciencias Veterinarias
dc.titleDetermination of the inter-observer and inter-scanner variability in the measurement of the renal resistive and renal pulsatility indices in dogs
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number196
dspace.entity.typePublication
relation.isAuthorOfPublication35c661fb-f1a7-43fc-8537-747888638565
relation.isAuthorOfPublication3eb43bc3-8d16-4188-b93c-2bd9df6a7c45
relation.isAuthorOfPublicationf13b99c1-ae25-4973-a376-2f06310a7481
relation.isAuthorOfPublication505de1e2-bdd2-4cae-a607-0b36fb9b9b4d
relation.isAuthorOfPublicationa125c566-21ed-4e30-a3ac-62b0d9d3ca3d
relation.isAuthorOfPublication.latestForDiscovery35c661fb-f1a7-43fc-8537-747888638565

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
REPRODUCIBILIDAD IHR.pdf
Size:
1.32 MB
Format:
Adobe Portable Document Format

Collections