Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery

dc.contributor.authorBarberá-Loustaunau, Emanuel
dc.contributor.authorCouñago, Felipe
dc.contributor.authorSánchez Tena, Miguel Ángel
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2025-04-23T12:46:22Z
dc.date.available2025-04-23T12:46:22Z
dc.date.issued2025-04-18
dc.description.abstractBackground/Objectives: To evaluate the efficacy and visual quality provided by the extended depth-of-focus AcrySof IQ Vivity lens (Alcon Laboratories, Inc., Fort Worth, TX, USA) in patients undergoing refractive lens exchange (RLE) surgery for presbyopia correction. Methods: This descriptive prospective single-arm clinical study included 30 patients (60 eyes) aged 49–69 years (mean 60.2) who underwent clear lens surgery for presbyopia correction. Postoperative 3-month assessments included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), distance-corrected intermediate visual acuity (DCIVA), and distance-corrected near visual acuity (DCNVA) measurements. Patient satisfaction and visual disturbances were evaluated using a standardized questionnaire. Results: Postoperative binocular visual acuity results were as follows: UDVA, 0.00 ± 0.06 logMAR; UIVA 0.08 ± 0.07 logMAR; and UNVA, 0.18 ± 0.10 logMAR. Refractive outcomes showed mean spherical equivalent values of −0.15 D ± 0.28 diopters (D) for the right eye and −0.18 D ± 0.30 D for the left eye postoperatively. Most patients (93.2%) were satisfied or very satisfied with the surgery, and 63.3% never needed glasses at any distance postoperatively. Mild and non-disabling photic phenomena were reported by 23% of patients for halos and 30% for glares. Conclusions: The study IOL provides excellent visual acuity for far and intermediate distances, as well as functional near vision under photopic conditions, with high levels of patient satisfaction and minimal visual disturbances. This lens is a promising option for non-cataract patients undergoing RLE for presbyopia correction.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipAlcon Lab. Investigator Initiated Trials 73499335
dc.description.statuspub
dc.identifier.citationBarberá-Loustaunau, E.; Couñago, F.; Sánchez-Tena, M.A.; Garzón, N. Visual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery. J. Clin. Med. 2025, 14, 2795. https://doi.org/10.3390/jcm14082795
dc.identifier.doi10.3390/jcm14082795
dc.identifier.issn2077-0383
dc.identifier.officialurlhttps//doi.org/10.3390/jcm14082795
dc.identifier.urihttps://hdl.handle.net/20.500.14352/119624
dc.issue.number8
dc.journal.titleJournal of Clinical Medicine
dc.language.isoeng
dc.page.initial2795
dc.publisherMDPI
dc.rights.accessRightsopen access
dc.subject.cdu617.7-089.243
dc.subject.keywordExtended depth-of-focus
dc.subject.keywordPresbyopia
dc.subject.keywordRefractive lens exchange
dc.subject.ucmCiencias
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco32 Ciencias Médicas
dc.subject.unesco22 Física
dc.titleVisual Results After Extended Depth-of-Focus Lens Implantation in Patients Undergoing Clear Lens Surgery
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number14
dspace.entity.typePublication
relation.isAuthorOfPublication1bbcfafa-1b33-4213-9a8d-2a1c633e8e85
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery1bbcfafa-1b33-4213-9a8d-2a1c633e8e85

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Visual_Results_After_Extended_Depth.pdf
Size:
884.95 KB
Format:
Adobe Portable Document Format

Collections