Development and evaluation of an IS711-based loop mediated isothermal amplification method (LAMP) for detection of Brucella spp. on clinical samples
dc.contributor.author | Pérez Sancho, Marta | |
dc.contributor.author | García-Seco Romero, María Teresa | |
dc.contributor.author | Arrogante, Lorena | |
dc.contributor.author | García, Nerea | |
dc.contributor.author | García Benzaquén, Nerea | |
dc.contributor.author | Martínez Alares, Irene | |
dc.contributor.author | Díez Guerrier, Alberto Antoine | |
dc.contributor.author | Perales, Agustina | |
dc.contributor.author | Goyache Goñi, Joaquín | |
dc.contributor.author | Domínguez Rodríguez, Lucas José | |
dc.contributor.author | Álvarez Sánchez, Julio | |
dc.date.accessioned | 2024-01-16T14:07:14Z | |
dc.date.available | 2024-01-16T14:07:14Z | |
dc.date.issued | 2013 | |
dc.description | 2013 Elsevier Ltd. All rights reserved; Financiación: AGL-2009-12674 (Ministerio de Ciencia e Innovación). Consejería de Educación de la Comunidad de Madrid y Fondo Social Europeo. EU FP7 ANTIGONE Project Number 278976. | |
dc.description.abstract | DNA-based methods have emerged as an additional tool for Brucella infection-confirmation at a herd level. However, their implementation may require the use of specialized equipment. In this context the recently developed loop-mediated isothermal amplification (LAMP) technique may constitute an additional and cost-effective tool for rapid and specific DNA detection, especially in low income areas. In the present study the usefulness of a newly developed LAMP assay aiming at the multicopy-IS711 sequence was assessed on a variety of clinical samples (n = 81 from abortions and ewes; cattle, n = 3; swine, n = 4) that were analyzed in parallel using real-time PCR and bacteriology. Although overall sensitivities obtained with the three methods were comparable (p > 0.05), our results highlighted the complementarity between bacteriology and molecular-based methods for increased sensitivity. Significant differences (p < 0.05) were observed with all techniques depending on the nature of the sample. Our results demonstrate the potential of the IS711-LAMP technique for direct Brucella detection. | |
dc.description.department | Depto. de Sanidad Animal | |
dc.description.faculty | Centro de Vigilancia Sanitaria Veterinaria (VISAVET) | |
dc.description.faculty | Fac. de Veterinaria | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Comunidad de Madrid | |
dc.description.sponsorship | Ministerio de Ciencia e Innovación (España) | |
dc.description.sponsorship | European Commission | |
dc.description.status | pub | |
dc.identifier.citation | Pérez-Sancho, M., García-Seco, T., Arrogante, L., García, N., Martínez, I., Diez-Guerrier, A., Perales, A., Goyache, J., Domínguez, L., & Alvarez, J. (2013). Development and evaluation of an IS711-based loop mediated isothermal amplification method (LAMP) for detection of Brucella spp. on clinical samples. Research in veterinary science, 95(2), 489–494. https://doi.org/10.1016/j.rvsc.2013.05.002 | |
dc.identifier.doi | 10.1016/j.rvsc.2013.05.002 | |
dc.identifier.essn | 1532-2661 | |
dc.identifier.issn | 0034-5288 | |
dc.identifier.officialurl | https://doi.org/10.1016/j.rvsc.2013.05.002 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/93391 | |
dc.issue.number | 2 | |
dc.journal.title | Research in Veterinary Science | |
dc.language.iso | eng | |
dc.page.final | 494 | |
dc.page.initial | 489 | |
dc.publisher | Elsevier | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
dc.rights.accessRights | restricted access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject.cdu | 636.09 | |
dc.subject.keyword | Bacteriology; Brucella; Loop mediated isothermal amplification; (LAMP); PCR | |
dc.subject.ucm | Veterinaria | |
dc.subject.ucm | Sanidad animal | |
dc.subject.unesco | 3109 Ciencias Veterinarias | |
dc.title | Development and evaluation of an IS711-based loop mediated isothermal amplification method (LAMP) for detection of Brucella spp. on clinical samples | |
dc.type | journal article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 95 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 94b7d8ef-e913-46ee-beeb-2d37b3caeb7f | |
relation.isAuthorOfPublication | 2afbcaa4-1eb6-44e1-bbcd-808c842cb8f7 | |
relation.isAuthorOfPublication | 08938f4f-d4f0-4b9c-a065-2df7e0b21f82 | |
relation.isAuthorOfPublication | 5fdbd68c-ea21-4625-ae57-296ae7183a64 | |
relation.isAuthorOfPublication | 2874329a-111b-4f7f-b5fd-4689903bc779 | |
relation.isAuthorOfPublication | a2216624-9e26-4185-85cd-7643dbddae2a | |
relation.isAuthorOfPublication | 5d5c3513-e6d9-451a-ba7d-ba0634c84bcf | |
relation.isAuthorOfPublication | 7a0cfc93-a3f1-45bf-b529-403f216cf8f7 | |
relation.isAuthorOfPublication.latestForDiscovery | 94b7d8ef-e913-46ee-beeb-2d37b3caeb7f |
Download
Original bundle
1 - 1 of 1