Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position

dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorJiménez Alfaro, Iñigo
dc.contributor.authorCuiña Sardiña, Ricardo
dc.contributor.authorMéndez Hernández, Carmen Dora
dc.contributor.authorBenítez Del Castillo Sánchez, José Manuel
dc.contributor.authorGarcía Sánchez, Julián
dc.date.accessioned2024-08-01T11:35:28Z
dc.date.available2024-08-01T11:35:28Z
dc.date.issued2003-01-01
dc.description.abstractObjective: To better elucidate the in vivo position of the Collamer posterior chamber phakic intraocular lens (PCPIOL) and its relationship to the iris and the crystalline lens and to analyze possible variations over time. Design: Prospective observational case series. Participants: Eighteen eyes of nine patients were included. Intervention: A Staar Collamer implantable PCPIOL was implanted for the correction of high myopia. Main Outcome Measures: The eyes were studied with a 50-MHz ultrasound biomicroscopy UBM 840. The exact PCPIOL position and the distances between it and the crystalline lens were measured at 3, 6, and 12 months after surgery. Results: There were no intraoperative complications. In 13 eyes (72.22%), contact between the PCPIOL and the crystalline lens was found at some time during follow-up. In 3 eyes (16.6%), central contact could be demonstrated. We also observed that the contact zone and its extension can vary over time. In 2 eyes, rotation of the lens was observed. Conclusions: We found contact between the PCPIOL and the crystalline lens in a high percentage of cases. There was also mobility of the lens in the posterior chamber, especially in the anteroposterior plane, and, as a consequence, both the contact zone and its extension would vary over time. © 2003 by the American Academy of Ophthalmology.
dc.description.departmentDepto. de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGarcía-Feijoó J, Alfaro IJ, Cuiña-Sardiña R, Méndez-Hernandez C, Del Castillo JM, García-Sánchez J. Ultrasound biomicroscopy examination of posterior chamber phakic intraocular lens position. Ophthalmology. 2003 Jan;110(1):163-72. doi: 10.1016/s0161-6420(02)01449-5. PMID: 12511362.
dc.identifier.doi10.1016/S0161-6420(02)01449-5
dc.identifier.essn1549-4713
dc.identifier.issn0161-6420
dc.identifier.officialurlhttps://doi.org/10.1016/S0161-6420(02)01449-5
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0161642002014495
dc.identifier.urihttps://hdl.handle.net/20.500.14352/107342
dc.issue.number1
dc.journal.titleOphthalmology
dc.language.isoeng
dc.page.final172
dc.page.initial163
dc.publisherElsevier
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu617.7
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco32 Ciencias Médicas
dc.titleUltrasound biomicroscopy examination of posterior chamber phakic intraocular lens position
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number110
dspace.entity.typePublication
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublicationa08d537d-093f-4d91-bd1a-f52ba4af4572
relation.isAuthorOfPublication533dd90f-2b34-4a5f-9cf8-ab8d19454edd
relation.isAuthorOfPublication1c7f939b-e6e5-45b0-aa9f-9892cb6e4378
relation.isAuthorOfPublicationeff24faf-e089-4604-906d-bbd7f42be7f1
relation.isAuthorOfPublication.latestForDiscovery533dd90f-2b34-4a5f-9cf8-ab8d19454edd

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0161642002014495-main.pdf
Size:
365.18 KB
Format:
Adobe Portable Document Format

Collections