Virtual Surgical Planning, Stereolitographic Models and CAD/CAM Titanium Mesh for Three-Dimensional Reconstruction of Fibula Flap with Iliac Crest Graft and Dental Implants

dc.contributor.authorNavarro Cuéllar, Carlos
dc.contributor.authorTousidonis Rial, Manuel
dc.contributor.authorAntúnez Conde, Raúl
dc.contributor.authorOchandiano Caicoya, Santiago
dc.contributor.authorNavarro Cuéllar, Ignacio
dc.contributor.authorArenas de Frutos, Gema
dc.contributor.authorSada Urmeneta, Ángela
dc.contributor.authorGarcía-Hidalgo Alonso, María Isabel
dc.contributor.authorNavarro Vila, Carlos León Martín Pascual
dc.contributor.authorSalmerón Escobar, José Ignacio
dc.date.accessioned2024-10-07T07:14:37Z
dc.date.available2024-10-07T07:14:37Z
dc.date.issued2021-04-29
dc.description.abstractMandibular reconstruction with fibula flap shows a 3D discrepancy between the fibula and the remnant mandible. Eight patients underwent three-dimensional reconstruction of the fibula flap with iliac crest graft and dental implants through virtual surgical planning (VSP), stereolitographic models (STL) and CAD/CAM titanium mesh. Vertical ridge augmentation and horizontal dimensions of the fibula, peri-implant bone resorption of the iliac crest graft, implant success rate and functional and aesthetic results were evaluated. Vertical reconstruction ranged from 13.4 mm to 10.1 mm, with an average of 12.22 mm. Iliac crest graft and titanium mesh were able to preserve the width of the fibula, which ranged from 8.9 mm to 11.7 mm, with an average of 10.1 mm. A total of 38 implants were placed in the new mandible, with an average of 4.75 ± 0.4 implants per patient and an osseointegration success rate of 94.7%. Two implants were lost during the osseointegration period (5.3%). Bone resorption was measured as peri-implant bone resorption at the mesial and distal level of each implant, with a variation between 0.5 mm and 2.4 mm, and with a mean of 1.43 mm. All patients were rehabilitated with a fixed implant prosthesis with good aesthetic and functional results.
dc.description.departmentDepto. de Cirugía
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationNavarro Cuéllar, C.; Tousidonis Rial, M.; Antúnez-Conde, R.; Ochandiano Caicoya, S.; Navarro Cuéllar, I.; Arenas de Frutos, G.; Sada Urmeneta, Á.; García-Hidalgo Alonso, M.I.; Navarro Vila, C.; Salmerón Escobar, J.I. Virtual Surgical Planning, Stereolitographic Models and CAD/CAM Titanium Mesh for Three-Dimensional Reconstruction of Fibula Flap with Iliac Crest Graft and Dental Implants. J. Clin. Med. 2021, 10, 1922. https://doi.org/10.3390/jcm10091922
dc.identifier.doi10.3390/jcm10091922
dc.identifier.issn2077-0383
dc.identifier.officialurlhttps://doi.org/10.3390/jcm10091922
dc.identifier.relatedurlhttps://www.mdpi.com/2077-0383/10/9/1922
dc.identifier.urihttps://hdl.handle.net/20.500.14352/108672
dc.issue.number9
dc.journal.titleJournal of Clinical Medicine
dc.language.isoeng
dc.page.initial1922
dc.publisherMDPI
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu617
dc.subject.keywordiliac crest graft
dc.subject.keywordvirtual surgical planning
dc.subject.keywordCAD/CAM
dc.subject.keywordtitanium mesh
dc.subject.keywordfibula flap
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco32 Ciencias Médicas
dc.titleVirtual Surgical Planning, Stereolitographic Models and CAD/CAM Titanium Mesh for Three-Dimensional Reconstruction of Fibula Flap with Iliac Crest Graft and Dental Implants
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number10
dspace.entity.typePublication
relation.isAuthorOfPublication546ee3a8-8426-4aa9-8814-c8ce8cdeacff
relation.isAuthorOfPublicatione5320a59-cd89-473c-a704-21d90081981b
relation.isAuthorOfPublicationc7c6bacd-439d-4ccb-a8c6-5c684ef70a1e
relation.isAuthorOfPublicationec7fb5be-b8a1-4e26-ab68-3a1e78220eca
relation.isAuthorOfPublication.latestForDiscovery546ee3a8-8426-4aa9-8814-c8ce8cdeacff

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jcm-Virtual Surgical Planning.pdf
Size:
11.88 MB
Format:
Adobe Portable Document Format
Description:
2021: Descuento MDPI

Collections