Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Espesor macular medido con tomografía de coherencia óptica en ojos pseudoafáquicos con implante amarillo vs. transparente

dc.contributor.authorChamorro Gutiérrez, Eva
dc.contributor.authorBonnin Arias, Cristina Natalia
dc.contributor.authorPérez Carrasco, María Jesús
dc.contributor.authorÁlvarez-Rementería Fernández, Laureano
dc.contributor.authorVilla Collar, César
dc.contributor.authorArmada Maresca, María Isabel
dc.contributor.authorSánchez Ramos, Celia
dc.date.accessioned2023-06-19T15:03:10Z
dc.date.available2023-06-19T15:03:10Z
dc.date.issued2014-04
dc.descriptionEstudios previos a este artículo han sido presentados en el 2nd World Congress on Controversies in Ophthalmology, el 4 de marzo de 2011 en Barcelona. Consultar texto completo en la url del editor: http://www.elsevier.es/fr-revista-archivos-sociedad-espanola-oftalmologia-296-articulo-espesor-macular-medido-con-tomografia-S036566911300405X?redirectNew=truees
dc.description.abstractObjetivo: Evaluar mediante tomografía de coherencia óptica (OCT) las variaciones de espesor macular producidas a lo largo del tiempo en ojos pseudoafáquicos implantados con una lente intraocular (LIO) transparente en comparación con sus respectivos ojos contralarerales implantados con LIO amarilla. Métodos: El espesor macular de 36 ojos de 18 sujetos fue evaluado mediante OCT. Los sujetos presentaban edades superiores a 65 años y habían sido intervenidos de cataratas en ambos ojos en 2 cirugías independientes. La principal característica de los individuos es que llevaban implantada una LIO con diferente absorción en cada ojo: transparente (absorbente de la radiación ultravioleta) y amarilla (con filtro adicional absorbente de las radiaciones violeta-azul del espectro visible). El espesor macular se evaluó en 2 sesiones separadas en el tiempo por un intervalo de tiempo de 5 años, mediante el sistema Stratus-OCT (protocolo fast macular thickness). Se analizaron estadísticamente las diferencias en la evolución del espesor macular entre ojos con diferente tipo de LIO. Resultados: Tras 5 años de seguimiento, se observó que los ojos implantados con LIO transparente manifestaban una reducción del espesor macular estadísticamente significativa, superior a la esperada por el aumento de la edad. Sin embargo, los ojos implantados con LIOs amarillas mantuvieron su espesor macular estable. La disminución del espesor macular promedio en ojos implantados con LIO transparente fue de 5 ± 8 μm (p = 0,02) y la reducción del espesor foveal fue de 10 ± 17 μm (p = 0,02). Conclusiones: Los cambios de espesor macular producidos en ojos implantados con una LIO amarilla difieren de los cambios manifestados en ojos con LIO transparente. Estas observaciones apuntan a un posible efecto protector de las LIOs amarillas contra los efectos dañinos de la luz en sujetos pseudoafáquicos. Sin embargo, estudios con un mayor tamaño muestral y mayor tiempo de seguimiento son necesarios para confirmar que la protección inducida por este tipo de LIO es clínicamente significativa.es
dc.description.abstractObjective: To study the use of optical coherence tomography (OCT), for measuring the macular thickness variations produced over time in elderly pseudophakic subjects implanted with a clear intraocular lens (IOL) in one eye, and a yellow IOL in the other eye. Methods: Macular thickness measurements were obtained in the 36 eyes of 18 subjects over 65 years, with cataracts surgically removed from both eyes and implanted with different absorbance (clear and yellow) IOLs in 2 separate surgeries. Stratus-OCT was used to determine the macular thickness in 2 sessions with 5 years of difference. Results: After 5 years of follow-up, the eyes implanted with clear IOLs revealed a significant decrease in macular thickness. However, in eyes implanted with yellow IOLs the macular thickness remained stable. The mean overall decrease in macular thickness in eyes implanted with clear IOLs was 5 ± 8 μm (P=.02), and foveal thickness reduction was 10 ± 17 μm (P=.02). Conclusions: The macular thickness changes produced in eyes implanted with a yellow IOL differ from those with a clear IOL. These observation point to a possible protective effect of yellow IOL against the harmful effects of light in elderly pseudophakic subjects. However, studies with a longer follow-up are still needed to confirm that the protection provided by this IOL model is clinically significant.en
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/38661
dc.identifier.citationChamorro Gutiérrez, E., Bonnin Arias, C. N., Pérez Carrasco, M. J. et al. «Espesor macular medido con tomografía de coherencia óptica en ojos pseudoafáquicos con implante amarillo vs. transparente». Archivos de la Sociedad Española de Oftalmología, vol. 89, n.o 4, abril de 2014, pp. 136-42. DOI.org (Crossref), https://doi.org/10.1016/j.oftal.2013.12.010.
dc.identifier.doi10.1016/j.oftal.2013.12.010
dc.identifier.issn0365-6691
dc.identifier.officialurlhttp://doi.org/10.1016/j.oftal.2013.12.010
dc.identifier.relatedurlhttp://www.sciencedirect.com/science/article/pii/S036566911300405X
dc.identifier.relatedurlhttp://www.elsevier.es/fr-revista-archivos-sociedad-espanola-oftalmologia-296-articulo-espesor-macular-medido-con-tomografia-S036566911300405X?redirectNew=true
dc.identifier.urihttps://hdl.handle.net/20.500.14352/35220
dc.issue.number4
dc.journal.titleArchivos de la Sociedad Española de Oftalmología
dc.language.isoeng
dc.page.final142
dc.page.initial136
dc.publisherElsevier España
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7-075.3
dc.subject.cdu617.736-003.87
dc.subject.keywordLentes intraoculares amarillas
dc.subject.keywordLentes intraoculares transparentes
dc.subject.keywordDaño inducido por la luz azul
dc.subject.keywordTomografía de coherencia óptica
dc.subject.keywordEspesor macular
dc.subject.keywordYellow intraocular lens
dc.subject.keywordClear intraocular lens
dc.subject.keywordBlue light damage
dc.subject.keywordOptical coherence tomography
dc.subject.keywordMacular thickness
dc.subject.ucmOftalmología
dc.subject.ucmLentes de contacto
dc.subject.ucmTécnicas de la imagen
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco3311.11 Instrumentos ópticos
dc.titleEspesor macular medido con tomografía de coherencia óptica en ojos pseudoafáquicos con implante amarillo vs. transparentees
dc.title.alternativeMacular thickness measured by optical coherence tomography in pseudoaphakic eyes with clear vs yellow implanten
dc.typejournal article
dc.volume.number89
dspace.entity.typePublication
relation.isAuthorOfPublicationbd1d6d70-bafd-4ab0-a203-4b33b5d9cff1
relation.isAuthorOfPublication7791e9b0-678d-49da-9010-8f913d903d58
relation.isAuthorOfPublicatione5280fc9-c932-4b4a-90b6-36ddb99d5e0f
relation.isAuthorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAuthorOfPublication.latestForDiscoverye5280fc9-c932-4b4a-90b6-36ddb99d5e0f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Espesor macular_ASEO-.pdf
Size:
682.74 KB
Format:
Adobe Portable Document Format

Collections