Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA Disculpen las molestias.
 

When less is more: the truncation of the optimal filter to reconstruct events in X-IFU/Athena-like TES detectors

dc.book.titleSpace telescope and instrumentation 2022: ultraviolet to gamma ray
dc.contributor.authorCeballos, M.T.
dc.contributor.authorCardiel López, Nicolás
dc.contributor.authorCobo, B.
dc.contributor.authorPeille, Philippe
dc.contributor.authorSmith, S.J.
dc.contributor.authorWitthoeft, M.C.
dc.contributor.authorDurkin, M.S.
dc.date.accessioned2023-06-16T13:04:32Z
dc.date.available2023-06-16T13:04:32Z
dc.date.issued2022
dc.description© (2022) Society of Photo-Optical Instrumentation Engineers (SPIE). Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray Part of SPIE Astronomical Telescopes and Instrumentation Conference (2022. Montreal, CANADA). M.T.Ceballos, N.Cardiel and B.Cobo acknowledge grant RTI2018-096686-B-C21 funded by MCIN/AEI/ 10.13039/501100011033 and by “ERDF A way of making Europe”.
dc.description.abstractThe X-ray Integral Field Unit (X-IFU) instrument to be on board the future ESA mission Athena X-ray Observatory is a cryogenic micro-calorimeter array of Transition Edge Sensor (TES) detectors aimed at providing spatially resolved high-resolution spectroscopy. As a part of the on-board Event Processor (EP), the reconstruction software will provide the energy, spatial location and arrival time of the incoming X-ray photons hitting the detector and inducing current pulses on it. Being the standard optimal filtering technique the chosen baseline reconstruction algorithm, a particular modification of this technique based on a truncation of the filter in the Time Domain (equivalent to 0-padding the pulse signal) was previously studied on simulated data, proving a better energy resolution results at a lower computational cost. However, the 0-padding technique also showed a larger sensitivity to instrumental conditions, making essential the analysis of its behaviour over real laboratory data. A comparative analysis of X-IFU-like TES laboratory data from NASA and NIST (at different instrumental conditions) with both the 0-padding filter and the standard optimal filters reconstruction shows that, once the corrections for the baseline drift and the jitter (phase introduced by the sampling rate) have been performed, the resolution values obtained using 0-padding are systematically lower than those of the standard filter of the same length and comparable or even lower to the values provided by the full-length filter. The shorter length of the 0-padding filter would be an additional benefit, reducing the computational cost of the reconstruction process.
dc.description.departmentDepto. de Física de la Tierra y Astrofísica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipthe MCIN/AEI/ 10.13039/501100011033
dc.description.sponsorshipthe ERDF "A way of making Europe"
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/77561
dc.identifier.doi10.1117/12.2631165
dc.identifier.isbn978-1-5106-5344-3; 978-1-5106-5343-6
dc.identifier.officialurlhttp://dx.doi.org/10.1117/12.2631165
dc.identifier.relatedurlhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie
dc.identifier.urihttps://hdl.handle.net/20.500.14352/2547
dc.language.isoeng
dc.publisherSpie-Int. Soc. Optical Engineering
dc.relation.ispartofseriesConference on Space Telescopes and Instrumentation
dc.relation.projectIDRTI2018-096686-B-C21
dc.rights.accessRightsopen access
dc.subject.cdu52
dc.subject.keywordAthena
dc.subject.keywordX-ray integral field unit
dc.subject.keywordX-ray spectroscopy
dc.subject.keywordSpace telescopes
dc.subject.keywordInstrumentation
dc.subject.keywordReconstruction methods
dc.subject.keywordPerformance analysis
dc.subject.ucmAstronomía (Física)
dc.titleWhen less is more: the truncation of the optimal filter to reconstruct events in X-IFU/Athena-like TES detectors
dc.typebook part
dc.volume.number12181
dspace.entity.typePublication
relation.isAuthorOfPublication2b15a442-d308-49d5-beda-1a98bb9db11e
relation.isAuthorOfPublication.latestForDiscovery2b15a442-d308-49d5-beda-1a98bb9db11e

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
cardiel124preprint.pdf
Size:
1.61 MB
Format:
Adobe Portable Document Format