Easyton ® transpalpebral versus Perkins applanation tonometry in different clinical populations

dc.contributor.authorMontolío Marzo, Elena
dc.contributor.authorMorales Fernández, Laura
dc.contributor.authorSáenz Francés, Federico
dc.contributor.authorGarcía Sáenz, Sofía
dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorPiñero, David Pablo
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.date.accessioned2023-06-22T12:40:23Z
dc.date.available2023-06-22T12:40:23Z
dc.date.issued2023-01-11
dc.description.abstractObjective: To compare intraocular pressure (IOP) measurements obtained using the new transpalpebral Easyton® tonometer and Perkins applanation tonometer (PAT) in three different clinical populations. Methods: The participants of this prospective study were 84 subjects divided into the groups: 22 healthy children (G1), 42 healthy adults (G2), and 20 adult patients with primary open angle glaucoma (G3). The data recorded in 84 eyes of these subjects were age, sex, eye, central corneal thickness (CCT) and axial length (AL). In all eyes, IOP was determined in the same examination room by the same experienced examiner using Easyton® and PAT in random order. Results: Mean differences in IOP readings between Easyton® and PAT were 0.45 ± 1.97 (p = 0.295), -0.15 ± 2.13 (p = 0.654), -1.65 ± 3.22 (p = 0.033), and − 0.018 ± 2.500 mmHg (p = 0.500) in the groups G1, G2, G3 and whole sample (G4), respectively. Correlations between Easyton® and PAT IOP values were 0.668 (p = 0.001) for G1, 0.463 (p = 0.002) for G2, 0.680 (p < 0.001) for G3 and 0.605 (p < 0.001) for G4. Moderate to good agreement between the two tonometers was found in all groups according to intraclass correlation coefficients, which were 0.794 (p < 0.001) for G1, 0.632 (p < 0.001) for G2, 0.809 (p < 0.001) for G3, and 0.740 (p < 0.001) for G4. The lower and upper limits of agreement between the devices were − 5.1 and 4.7 mmHg, respectively. No correlation was noted between CCT or AL and the Easyton® IOP measurements. Conclusion: IOP measurements obtained with Easyton® and PAT show an acceptable level of agreement both in healthy individuals and in patients with glaucoma.en
dc.description.departmentDepto. de Inmunología, Oftalmología y ORL
dc.description.departmentUnidad Docente de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Medicina
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statusunpub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/76777
dc.identifier.citationMontolío Marzo, E., Morales Fernández, L., Sáenz Francés, F. et al. Easyton ® transpalpebral versus Perkins applanation tonometry in different clinical populations. 11 de enero de 2023. In Review, https://doi.org/10.21203/rs.3.rs-2455817/v1.
dc.identifier.doi10.21203/rs.3.rs-2455817/v1
dc.identifier.officialurlhttps://doi.org/10.21203/rs.3.rs-2455817/v1
dc.identifier.urihttps://hdl.handle.net/20.500.14352/73025
dc.language.isoeng
dc.page.initial10 p.
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu617.7-007.681
dc.subject.cdu617.7-073.178
dc.subject.cdu612.842.6
dc.subject.keywordGlaucoma
dc.subject.keywordEasyton™ transpalpebral tonometer
dc.subject.keywordIntraocular pressure
dc.subject.keywordPerkinsTM
dc.subject.keywordPerkins™ tonometer
dc.subject.ucmOftalmología
dc.subject.unesco3201.09 Oftalmología
dc.titleEasyton ® transpalpebral versus Perkins applanation tonometry in different clinical populationsen
dc.typejournal article
dspace.entity.typePublication
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication.latestForDiscovery558b8023-6d72-4dff-9f99-2e60f6f31843

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
77ae789a-9bb5-4a73-8659-2df81a6a0fda.pdf
Size:
377.95 KB
Format:
Adobe Portable Document Format

Collections