Power profile and optical performance of two extended range of vision intraocular lens designs

dc.contributor.authorVega, Fidel
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorGarcía Montero, María
dc.contributor.authorMillán, María Sagrario
dc.date.accessioned2024-12-11T12:20:27Z
dc.date.available2024-12-11T12:20:27Z
dc.date.issued2024-10-01
dc.descriptionSupported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (F.V., N.G., M.S.M.) and PID2021-122486OA-I00 (M.G.-M., N.G.) from the Spanish Agencia Estatal de Investigación. Submitted: January 25, 2024 | Final revision submitted: July 6, 2024 | Accepted: July 10, 2024
dc.description.abstractPurpose: To assess the power profile and optical performance of 2 extended range-of-vision (ERV) intraocular lenses (IOLs), TECNIS Eyhance (ICB00) and LuxSmart, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS 1-piece (ZCB00) and LuxGood, respectively. Setting: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. Design: Laboratory investigation on optical bench. Methods: For each design, the power distribution and (fourth and sixth-order) spherical aberration (SA) across the lens aperture were measured as well as the optical performance using modulation transfer function–based metrics with through-focus evaluation. 3 nominal powers (+10.00 diopters [D], +20.00 D, and +30.00 D) and 3 pupil sizes (2.0 mm, 3.0 mm, and 4.5 mm) were considered to assess whether the base power of the lens and pupillary dynamics have an influence on the depth-of-focus extension. Results: TECNIS Eyhance and LuxSmart IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmart had a greater add power while TECNIS Eyhance showed higher peak optical quality but smaller depth of focus. Conclusions: Differences of focus extension between the 2 ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs has little effect on their optical quality. However, pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Ciencia e Innovación (España)
dc.description.statuspub
dc.identifier.citationVega, Fidel PhD; Garzón, Nuria PhD; García-Montero, María PhD; Millán, María S. PhD. Power profile and optical performance of two extended range-of-vision intraocular lens designs. Journal of Cataract & Refractive Surgery 50(10):p 1065-1073, October 2024. | DOI: 10.1097/j.jcrs.0000000000001528
dc.identifier.doi10.1097/j.jcrs.0000000000001528
dc.identifier.essn1873-4502
dc.identifier.issn0886-3350
dc.identifier.officialurlhttps://doi.org/10.1097/j.jcrs.0000000000001528
dc.identifier.pmid39025665
dc.identifier.relatedurlhttps://journals.lww.com/jcrs/fulltext/2024/10000/power_profile_and_optical_performance_of_two.13.aspx
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112430
dc.issue.number10
dc.journal.titleJournal Cataract Refractive Surgery
dc.language.isoeng
dc.page.final1073
dc.page.initial1065
dc.publisherLippincott, Williams & Wilkins - Wolters Kluwer
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020./PID2020-114582RB-I00/AEI/10.13039/501100011033/IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica, Técnica y de Innovación 2021 -2023/PID2021-122486OA-I00/ES/Diseño de algoritmo de decisión clínica en el proceso de selección del tipo de LIO a implantar para corregir la presbicia y cataratas Design of a clinical decision algorithm in the selection process of the type of IOL to be implanted to correct presbyo
dc.rights.accessRightsembargoed access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.cdu617.75
dc.subject.keywordIntracular lens
dc.subject.keywordMonofocal advanced
dc.subject.keywordMultifocal
dc.subject.keywordPresbyopia
dc.subject.keywordEDOF
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3311.09 Lentes
dc.subject.unesco2209.15 Optometría
dc.subject.unesco2209 Óptica
dc.titlePower profile and optical performance of two extended range of vision intraocular lens designs
dc.typejournal article
dc.type.hasVersionSMUR
dc.volume.number50
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Preprint_jcrs_24_112_final.pdf
Size:
739.55 KB
Format:
Adobe Portable Document Format
Description:
Versión preprint aceptada
Loading...
Thumbnail Image
Name:
Proof_final_power_profile_and_optical_performance_of_two.pdf
Size:
1.11 MB
Format:
Adobe Portable Document Format
Description:
Postprint versión maquetada

Collections