Power profile and optical performance of two extended range of vision intraocular lens designs
dc.contributor.author | Vega, Fidel | |
dc.contributor.author | Garzón Jiménez, Nuria | |
dc.contributor.author | García Montero, María | |
dc.contributor.author | Millán, María Sagrario | |
dc.date.accessioned | 2024-12-11T12:20:27Z | |
dc.date.available | 2024-12-11T12:20:27Z | |
dc.date.issued | 2024-10-01 | |
dc.description | Supported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (F.V., N.G., M.S.M.) and PID2021-122486OA-I00 (M.G.-M., N.G.) from the Spanish Agencia Estatal de Investigación. Submitted: January 25, 2024 | Final revision submitted: July 6, 2024 | Accepted: July 10, 2024 | |
dc.description.abstract | Purpose: To assess the power profile and optical performance of 2 extended range-of-vision (ERV) intraocular lenses (IOLs), TECNIS Eyhance (ICB00) and LuxSmart, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS 1-piece (ZCB00) and LuxGood, respectively. Setting: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. Design: Laboratory investigation on optical bench. Methods: For each design, the power distribution and (fourth and sixth-order) spherical aberration (SA) across the lens aperture were measured as well as the optical performance using modulation transfer function–based metrics with through-focus evaluation. 3 nominal powers (+10.00 diopters [D], +20.00 D, and +30.00 D) and 3 pupil sizes (2.0 mm, 3.0 mm, and 4.5 mm) were considered to assess whether the base power of the lens and pupillary dynamics have an influence on the depth-of-focus extension. Results: TECNIS Eyhance and LuxSmart IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmart had a greater add power while TECNIS Eyhance showed higher peak optical quality but smaller depth of focus. Conclusions: Differences of focus extension between the 2 ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs has little effect on their optical quality. However, pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Ciencia e Innovación (España) | |
dc.description.status | pub | |
dc.identifier.citation | Vega, Fidel PhD; Garzón, Nuria PhD; García-Montero, María PhD; Millán, María S. PhD. Power profile and optical performance of two extended range-of-vision intraocular lens designs. Journal of Cataract & Refractive Surgery 50(10):p 1065-1073, October 2024. | DOI: 10.1097/j.jcrs.0000000000001528 | |
dc.identifier.doi | 10.1097/j.jcrs.0000000000001528 | |
dc.identifier.essn | 1873-4502 | |
dc.identifier.issn | 0886-3350 | |
dc.identifier.officialurl | https://doi.org/10.1097/j.jcrs.0000000000001528 | |
dc.identifier.pmid | 39025665 | |
dc.identifier.relatedurl | https://journals.lww.com/jcrs/fulltext/2024/10000/power_profile_and_optical_performance_of_two.13.aspx | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/112430 | |
dc.issue.number | 10 | |
dc.journal.title | Journal Cataract Refractive Surgery | |
dc.language.iso | eng | |
dc.page.final | 1073 | |
dc.page.initial | 1065 | |
dc.publisher | Lippincott, Williams & Wilkins - Wolters Kluwer | |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020./PID2020-114582RB-I00/AEI/10.13039/501100011033/IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA | |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica, Técnica y de Innovación 2021 -2023/PID2021-122486OA-I00/ES/Diseño de algoritmo de decisión clínica en el proceso de selección del tipo de LIO a implantar para corregir la presbicia y cataratas Design of a clinical decision algorithm in the selection process of the type of IOL to be implanted to correct presbyo | |
dc.rights.accessRights | embargoed access | |
dc.subject.cdu | 617.7-089.243 | |
dc.subject.cdu | 681.73 | |
dc.subject.cdu | 617.75 | |
dc.subject.keyword | Intracular lens | |
dc.subject.keyword | Monofocal advanced | |
dc.subject.keyword | Multifocal | |
dc.subject.keyword | Presbyopia | |
dc.subject.keyword | EDOF | |
dc.subject.ucm | Óptica y optometría | |
dc.subject.ucm | Óptica oftálmica | |
dc.subject.unesco | 3311.09 Lentes | |
dc.subject.unesco | 2209.15 Optometría | |
dc.subject.unesco | 2209 Óptica | |
dc.title | Power profile and optical performance of two extended range of vision intraocular lens designs | |
dc.type | journal article | |
dc.type.hasVersion | SMUR | |
dc.volume.number | 50 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 367ce491-287f-4b2a-ba6a-870a393c5609 | |
relation.isAuthorOfPublication | 9b637d56-481e-40c6-a0e6-eb4de92e663c | |
relation.isAuthorOfPublication.latestForDiscovery | 367ce491-287f-4b2a-ba6a-870a393c5609 |
Download
Original bundle
1 - 2 of 2
Loading...
- Name:
- Preprint_jcrs_24_112_final.pdf
- Size:
- 739.55 KB
- Format:
- Adobe Portable Document Format
- Description:
- Versión preprint aceptada
Loading...
- Name:
- Proof_final_power_profile_and_optical_performance_of_two.pdf
- Size:
- 1.11 MB
- Format:
- Adobe Portable Document Format
- Description:
- Postprint versión maquetada