Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional: Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.
 

Power profile and optical performance of two extended range of vision intraocular lens designs

dc.contributor.authorVega, Fidel
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorGarcía Montero, María
dc.contributor.authorMillán, María Sagrario
dc.date.accessioned2024-12-11T12:20:27Z
dc.date.available2024-12-11T12:20:27Z
dc.date.issued2024-10-01
dc.descriptionSupported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (F.V., N.G., M.S.M.) and PID2021-122486OA-I00 (M.G.-M., N.G.) from the Spanish Agencia Estatal de Investigación. Submitted: January 25, 2024 | Final revision submitted: July 6, 2024 | Accepted: July 10, 2024
dc.description.abstractPurpose: To assess the power profile and optical performance of 2 extended range-of-vision (ERV) intraocular lenses (IOLs), TECNIS Eyhance (ICB00) and LuxSmart, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS 1-piece (ZCB00) and LuxGood, respectively. Setting: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. Design: Laboratory investigation on optical bench. Methods: For each design, the power distribution and (fourth and sixth-order) spherical aberration (SA) across the lens aperture were measured as well as the optical performance using modulation transfer function–based metrics with through-focus evaluation. 3 nominal powers (+10.00 diopters [D], +20.00 D, and +30.00 D) and 3 pupil sizes (2.0 mm, 3.0 mm, and 4.5 mm) were considered to assess whether the base power of the lens and pupillary dynamics have an influence on the depth-of-focus extension. Results: TECNIS Eyhance and LuxSmart IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmart had a greater add power while TECNIS Eyhance showed higher peak optical quality but smaller depth of focus. Conclusions: Differences of focus extension between the 2 ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs has little effect on their optical quality. However, pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Ciencia e Innovación (España)
dc.description.statuspub
dc.identifier.citationVega, Fidel PhD; Garzón, Nuria PhD; García-Montero, María PhD; Millán, María S. PhD. Power profile and optical performance of two extended range-of-vision intraocular lens designs. Journal of Cataract & Refractive Surgery 50(10):p 1065-1073, October 2024. | DOI: 10.1097/j.jcrs.0000000000001528
dc.identifier.doi10.1097/j.jcrs.0000000000001528
dc.identifier.essn1873-4502
dc.identifier.issn0886-3350
dc.identifier.officialurlhttps://doi.org/10.1097/j.jcrs.0000000000001528
dc.identifier.pmid39025665
dc.identifier.relatedurlhttps://journals.lww.com/jcrs/fulltext/2024/10000/power_profile_and_optical_performance_of_two.13.aspx
dc.identifier.urihttps://hdl.handle.net/20.500.14352/112430
dc.issue.number10
dc.journal.titleJournal Cataract Refractive Surgery
dc.language.isoeng
dc.page.final1073
dc.page.initial1065
dc.publisherLippincott, Williams & Wilkins - Wolters Kluwer
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020./PID2020-114582RB-I00/AEI/10.13039/501100011033/IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/ Plan Estatal de Investigación Científica, Técnica y de Innovación 2021 -2023/PID2021-122486OA-I00/ES/Diseño de algoritmo de decisión clínica en el proceso de selección del tipo de LIO a implantar para corregir la presbicia y cataratas Design of a clinical decision algorithm in the selection process of the type of IOL to be implanted to correct presbyo
dc.rights.accessRightsembargoed access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.cdu617.75
dc.subject.keywordIntracular lens
dc.subject.keywordMonofocal advanced
dc.subject.keywordMultifocal
dc.subject.keywordPresbyopia
dc.subject.keywordEDOF
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3311.09 Lentes
dc.subject.unesco2209.15 Optometría
dc.subject.unesco2209 Óptica
dc.titlePower profile and optical performance of two extended range of vision intraocular lens designs
dc.typejournal article
dc.type.hasVersionSMUR
dc.volume.number50
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Preprint_jcrs_24_112_final.pdf
Size:
739.55 KB
Format:
Adobe Portable Document Format
Description:
Versión preprint aceptada
Loading...
Thumbnail Image
Name:
Proof_final_power_profile_and_optical_performance_of_two.pdf
Size:
1.11 MB
Format:
Adobe Portable Document Format
Description:
Postprint versión maquetada

Collections