Medium-term clinical outcomes following Xen45 device implantation

dc.contributor.authorFernández García, Aitor
dc.contributor.authorZhou, Ying
dc.contributor.authorGarcía Alonso, Mercedes
dc.contributor.authorAndrango, Henry D.
dc.contributor.authorPoyales Galán, Francisco
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2023-06-16T15:15:26Z
dc.date.available2023-06-16T15:15:26Z
dc.date.issued2019-11
dc.descriptionReceived: 7 august 2019; Accepted: 16 november 2019
dc.description.abstractPurpose: To evaluate medium-term clinical outcomes with microstent XEN® 45 Gel Stent (Allergan Dublin, Ireland) for treatment of primary open-angle glaucoma (POAG). Material and methods: This is a retrospective, descriptive and observational study involving 93 eyes from 63 patients who had undergone POAG surgery with a XEN® 45 Gel Stent implantation and had been followed up and controlled between 12 and 36 months. Results: IOP dropped from 18.23 ± 5.00 mmHg pre-op to 14.16 ± 2.14, 14.47 ± 2.16 and 14.63 ± 1.91 at 1, 2 and 3 years after surgery (p = 0.000, 0.000 and 0.001) consecutively. Mean number of medications dropped from 1.87 ± 0.94 preoperatively to 0.31 ± 0.69, 0.34 ± 0.63 and 1.00 ± 0.88 (p = 0.000, 0.000 and 0.017) at 12, 24 and 36 months. Mean visual field deviation values never turned out to be significant for any of the follow-up visit data. A total of 94.6% of the surgical procedures turned out to be complication-free. In one surgery, the procedure failed and 18 months later other device was implanted. Conclusion: POAG surgical procedures with XEN® 45 Gel Stent implants are a safe and effective treatment approach.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/58079
dc.identifier.doi10.1007/s10792-019-01232-3
dc.identifier.issn0165-5701
dc.identifier.officialurlhttps://doi.org/10.1007/s10792-019-01232-3
dc.identifier.relatedurlhttps://link.springer.com/article/10.1007%2Fs10792-019-01232-3
dc.identifier.urihttps://hdl.handle.net/20.500.14352/5978
dc.journal.titleInternational Ophthalmology
dc.language.isoeng
dc.publisherSpringer Verlag
dc.rights.accessRightsopen access
dc.subject.cdu617.7-007.681-089
dc.subject.keywordGlaucoma
dc.subject.keywordMIGS
dc.subject.keywordXen45
dc.subject.ucmCirugía
dc.subject.ucmOftalmología
dc.subject.unesco3213 Cirugía
dc.subject.unesco3201.09 Oftalmología
dc.titleMedium-term clinical outcomes following Xen45 device implantation
dc.typejournal article
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Nuria Garzón_ACFrOgBYmCQ8nY3DY0VVtn1SXLp40-Y1uo9ilTeTfpw2KsiwJZT_AZa9GAcmn0lxSB7iqsE-9Xi2x5eTVj6ZIbq3DMJuSGi04UaUG2EavZHShBJ_N3flppRweq14Cxc=.pdf
Size:
677.56 KB
Format:
Adobe Portable Document Format

Collections