Temporary monitoring of the microclimate in a museum without climate control and its implications in the preventive conservation of collections

dc.contributor.authorVaras Muriel, María Josefa
dc.contributor.authorGómez Marfil, Amanda
dc.contributor.authorÁlvarez de Buergo, Mónica
dc.contributor.authorFort González, Rafael
dc.date.accessioned2025-09-26T16:22:23Z
dc.date.available2025-09-26T16:22:23Z
dc.date.issued2025-10-01
dc.description.abstractSmall museums focusing on research and teaching are common in cities worldwide, particularly within universities and research institutions. Very few, however, have microclimate control in place that ensures conservation of their collections. The Professor Reverte Coma Museum of Medical Anthropology at the Complutense University of Madrid (Spain) is one such case. The changes in the environmental conditions inside the museum over a short period were evaluated due to an unexpected situation (COVID-19) that disrupted its usual operation. Additionally, the influence of these temporary variations on the conservation ranges of the different exhibited objects was determined. Most of the objects require strict hygrothermal ranges, which were not met in either the rooms or the showcases. Since the environmental conditions of this museum cannot be artificially controlled, environmental disturbances occurred within just 10 days, which affected the conservation ranges. It was also demonstrated that most of the showcases reflected the microclimates of the rooms, thereby failing to fulfill their intended function of environmental protection. In this exceptional situation, the objects are not being maintained within the target environmental ranges, which poses a potential conservation risk. Should an unexpected sequence of abrupt changes in the microclimate occur over a brief period, the objects may incur mechanical damage, as they will not have had sufficient time to acclimatize. Consequently, it is essential to monitor such isolated events to determine if temporary and emergency conservation strategies need to be developed and applied in the future.
dc.description.departmentDepto. de Mineralogía y Petrología
dc.description.facultyFac. de Ciencias Geológicas
dc.description.refereedTRUE
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.identifier.citationVaras-Muriel, M. J., Gómez-Marfil, A., Álvarez De Buergo, M., & Fort, R. (2025). Temporary monitoring of the microclimate in a museum without climate control and its implications in the preventive conservation of collections. Building and Environment, 284, 113507. https://doi.org/10.1016/j.buildenv.2025.113507
dc.identifier.doi10.1016/j.buildenv.2025.113507
dc.identifier.essn1873-684X
dc.identifier.issn0360-1323
dc.identifier.officialurlhttps://doi.org/10.1016/j.buildenv.2025.113507
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0360132325009801
dc.identifier.urihttps://hdl.handle.net/20.500.14352/124360
dc.issue.number113507
dc.journal.titleBuilding and Environment
dc.language.isoeng
dc.publisherElsevier
dc.relation.projectIDTEC-2024/TEC-39
dc.relation.projectIDUCM (921349)
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.cdu697:727.7
dc.subject.keywordTemporary monitoring,
dc.subject.keywordNatural and induced microclimates
dc.subject.keywordPreventive conservation
dc.subject.keywordMuseum
dc.subject.keywordShowcases
dc.subject.ucmCiencias
dc.subject.unesco3305 Tecnología de la Construcción
dc.titleTemporary monitoring of the microclimate in a museum without climate control and its implications in the preventive conservation of collections
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number284
dspace.entity.typePublication
relation.isAuthorOfPublication00ca5323-0651-4b63-a8cf-fe26b08f39b8
relation.isAuthorOfPublication.latestForDiscovery00ca5323-0651-4b63-a8cf-fe26b08f39b8

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Temporary monitoring of the microclimate.pdf
Size:
13.73 MB
Format:
Adobe Portable Document Format

Collections